Waktu Perkhidmatan: Isnin hingga Jumaat 9:00-18:00
WM14DINAV53LR2S1AX - WM14DINAV53LR2S1AX CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING DIN Rail POWER SUPPLY..
Dalam Stok Produk Hangat

WM14DINAV53LR2S1AX

WM14DINAV53LR2S1AX CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING DIN Rail POWER SUPPLY..

$0.00USD
4092 dalam stok
Maklumat Pembekal
CARLO GAVAZZI
CARLO GAVAZZI
Produk: 10094
Biasanya dihantar dalam 2-3 hari bekerja
Kualiti Dijamin
Penghantaran Pantas
Sokongan Teknikal

Penerangan Produk

Three-Phase Power Analyzer, Built-in Programming Keypad, Advanced Version, Din Rail
Ciri-ciri Utama
  • Kualiti gred industri
  • Patuh RoHS
  • Sijil CE
  • Jaminan 1 tahun

Butiran Teknikal

Energy ManagementPower AnalyzerType WM14 DIN “Advanced version”• Protection degree (front): IP40• 2 digital outputs• 16 freely configurable alarms with OR/AND logic linkable with up to 2 digital outputs• RS422/485 serial output (MODBUS-RTU), iFIX SCADAcompatibilityProduct Description• Class 1 (kWh), Class 2 (kvarh)• Accuracy ±0.5 F.S. (current/voltage)• Power Analyzer• Instantaneous variables read-out: 3 DGT• Energies readout: 8+1 DGT• System variables: VLL, VLN, An, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmdmax, var, PF, Hz, ASY• Single phase variables: VLL, VLN, VLN min, VLN max, A, Amin, Amax, Admd, VA, W, Wdmd, Wmax, var, PF, PFmin• Harmonic analysis (FFT) up to the 15thharmonic (cur-rent and voltage)• Four quadrant power measurement• Energy measurements: total and partial kWh and kvarh• Hour counter (5+2 DGT)• TRMS meas. of distorted sine waves (voltages/currents)• Universal power supply: 90 to 260 VAC/DC, 18 to 60 VAC/DC• Front dimensions: 107,8x90mm (6 DIN modules)• Voltage asymmetry, phase sequence, phase loss controlHow to order WM14-DIN AV53 H R2 S1 AX3-phase advanced power analyzer with integrated pro- gramming key-pad. Particu- larly recommended for the measurement of the main electrical variables.Housing for DIN-RAIL mount- ing, with RS485 communica- tion port or pulse and/or alarm outputs.Model Range code SystemPower supplyOutput 1Output 2OptionType SelectionRange codesAV5: 380/660VL-L/1/5(6)AAC VL-N: 185 V to 460 VVL-L: 320 V to 800 VAV6: 120/208VL-L/1/5(6)AAC VL-N: 45 V to 145 VVL-L: 78 V to 250 VSystem3 :1, 2 or 3 phase, balanced/unbalanced load, with or without neutralPower supplyOutput 1R2: 2-relay outputsO2: 2-open collector outputsOutput 2XX: NoneS1: RS485/RS422 portOptionsPhase current: 0.03A to 6ANeutral current: 0.09A to 6AL: 18 to 60 VAC/VDCH: 90 to 260 VAC/VDCAX: advanced functionsInputspecificationsRated inputsSystem type: 3 - phaseCurrent3 (by Shunts) Voltage4Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,400VLL AV6: 285W-VA-var, FS:57VLN, 100VLLCurrent 0.25 to 6A: ±(0.5% FS +1DGT)0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)0.09Ato0.25A:±(1.5%FS+7DGT)Phase-phase voltage ±(1.5% FS +1 DGT)Phase-neutral voltage ±(0.5% FS + 1 DGT)Active and Apparent power,0.25 to 6A: ±(1% FS +1DGT)0.03A to 0.25A: ±(1% FS+5DGT)Reactive power 0.25 to 6A: ±(2% FS +1DGT)0.03A to 0.25A: ±(2% FS+5DGT)Active energy Class 1 (start up current: 30mA) Reactive energyClass 2 (start up current: 30mA) Frequency±0.1Hz (48 to 62Hz) Harmonic distortion ±3% F.S. (up to 15th harmonic)(F.S.: 100%)Specifications are subject to change without noticeWM14 DIN A DS ENG230508 1

Dokumen Produk

Lembaran Data

Spesifikasi teknikal dan data prestasi

Manual Pengguna

Panduan pemasangan dan operasi