Waktu Perkhidmatan: Isnin hingga Jumaat 9:00-18:00
WM1496AV53HDG - WM1496AV53HDG CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 2..
Dalam Stok Produk Hangat

WM1496AV53HDG

WM1496AV53HDG CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 2..

$0.00USD
3503 dalam stok
Maklumat Pembekal
CARLO GAVAZZI
CARLO GAVAZZI
Produk: 10094
Biasanya dihantar dalam 2-3 hari bekerja
Kualiti Dijamin
Penghantaran Pantas
Sokongan Teknikal

Penerangan Produk

Three-Phase Power Analyzer, Built-in Programming Keypad, Basic Version, 96X96 Panel
Ciri-ciri Utama
  • Kualiti gred industri
  • Patuh RoHS
  • Sijil CE
  • Jaminan 1 tahun

Butiran Teknikal

Energy ManagementPower AnalyzerType WM14-96 “Profibus DP”• Protection degree (front): IP65• Front dimensions: 96x96mm• Class 1 (active energy)• Class 2 (reactive energy)• Accuracy ±0.5 F.S. (current/voltage)• Power analyzer• Display of instantaneous variables: 3x3 digit• Display of energies: 8+1 digit• System variables and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz• Amax, Admd max, Wdmdmaxindication• Energy measurements: kWh and kvarh• Hour counter (5+2 DGT)• TRMS meas. of distorted sine waves (voltages/currents)• Galvanically insulated measuring inputs• Profibus DP-V0 serial port• Alarms (visual only) VLN, An• Power supply: 90 to 260VAC/DCProduct DescriptionHow to orderWM14-96AV5 3 H DGX3-phase power analyzer with built-in programming key- pad. Particularly recom- mended for displaying the main electrical variables.Housing for panel mounting, (front) protection degree IP65 and Profibus DP communica- tion port.Model Range code SystemPower supplyOptionType SelectionRange codesAV5: 380/660VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 VAV6: 120/208VL-L/5(6)AAC VL-N: 45 V to 145 VVL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6ASystem3 :1-2-3-phase, balanced/unbalanced load,with or without neutralPower supplyH: 90 to 260VAC/DCOptionsDG:Profibus DP + galvanic insulated measuring inputsInputspecificationsRated inputsCurrent 3Voltage 4Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,400VLL AV6: 285W-VA-var, FS:57VLN, 100VLLCurrent 0.25 to 6A: ±(0.5% FS +1DGT)0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)0.09Ato0.25A:±(0.5%FS+7DGT) Phase-phase voltage ±(1.5% FS +1 DGT)Phase-neutral voltage ±(0.5% FS + 1 DGT)Active and Apparent power 0.25 to 6A: ±(1% FS +1DGT)0.03A to 0.25A: ±(1% FS+5DGT)Reactive power 0.25 to 6A: ±(2% FS +1DGT)0.03Ato0.25A:±(2%FS +5DGT) Active energy Class 1 (start up “I”: 30mA) Reactive energyClass 2 (start up “I”: 30mA)Frequency±0.1Hz (48 to 62Hz)Additional errorsHumidity≤0.3% FS, 60% to 90% RHTemperature drift≤ 200ppm/°CSampling rate1400 samples/s @ 50Hz1700 samples/s @ 60HzDisplay refresh time700msDisplayTypeLED, 14mmRead-out for instant. var.3x3 DGTRead-out for energies 3+3+3 DGT (Max indication:999 999 99.9)Read-out for hour counter 1+3+3 DGT (Max. indication:9 999 9.99)MeasurementsCurrent, voltage, power, power factor, frequency, energy, TRMS measurement of distorted waves.Coupling type DirectSpecifications are subject to change without noticeWM14-96PDS 080906 1

Dokumen Produk

Lembaran Data

Spesifikasi teknikal dan data prestasi

Manual Pengguna

Panduan pemasangan dan operasi

Top