| Parameter | Nilai |
|---|---|
| GTIN | 4046356474405 |
| Nota | Made to Order (non-returnable) |
| (Kabel) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Kunci Pesanan | 1416350 |
| Halaman katalog | Page 397 (C-2-2017) |
| Unit pembungkusan | 1 pc |
| (Data umum) | < 100 mΩ (at 100 MHz) |
| Negara asal | DE (Germany) |
| RoHS China (Kabel) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Kabel) | Lead 7439-92-1 |
| Nombor tarif tersuai | 85444290 |
| Perisai (Data umum) | Aluminum-lined polyester foil, tinned copper braided shield |
| Jenis kabel (Data umum) | Ethernet |
| Warna wayar (Data umum) | White-blue, white-orange, white-green, white-brown |
| Berat kabel (Data umum) | 55 kg/km |
| Bebas halogen (Data umum) | According to IEC 60754-2 |
| Kelajuan isyarat (Data umum) | 0.6 c |
| Gaya UL AWM (Data umum) | 10797 (80°C/30 V) |
| Berat tembaga (Data umum) | 32.8 kg/km |
| Kelainan keseluruhan (Data umum) | 4 pairs, twisted |
| Pasangan berpintal (Data umum) | 2 cores to the pair |
| Kapasiti kabel (Data umum) | < 56 nF/km |
| Masa jalan isyarat (Data umum) | 5.7 ns/m |
| Impedans gelombang (Data umum) | 100 Ω ±5 Ω (at 100 MHz) |
| Talian isyarat AWG (Data umum) | 23 |
| Impedans kabel (Data umum) | < 5 mΩ (with 1 MHz) |
| Struktur kabel (Data umum) | 4x2xAWG23/1; S/FTP |
| Rintangan api (Data umum) | according to IEC 60332-3-24 (Cat. C ) |
| Bilangan jawatan (Dimensi) | 8 |
| Rintangan terhadap minyak (Data umum) | according to IEC 60811-2-1 |
| Bahan konduktor (Data umum) | Bare Cu wire |
| Jenis/kategori isyarat (Dimensi) | Ethernet CAT7, 10 Gbps |
| Rintangan konduktor (Data umum) | < 75 Ω/km |
| Jenis/kategori isyarat (Data umum) | Ethernet CAT7, 10 Gbps |
| Kekuatan tegangan GRP (Data umum) | 80 N |
| Rintangan penebat (Data umum) | > 5 GΩ*km |
| Berat setiap Keping (tidak termasuk pembungkusan) | 6,572.000 g |
| Kepekatan wasap (Data umum) | in accordance with IEC 61034 |
| Sarung luaran, warna (Data umum) | water blue RAL 5021 |
| Panjang kabel (Data Komersial Utama) | 100 m |
| Voltan nominal, kabel (Data umum) | 30 V AC |
| Sarung luar, bahan (Data umum) | FRNC |
| Teras/Teras voltan ujian (Data umum) | 2500 V DC |
| Jenis pelindung pasangan (Data umum) | Aluminum-lined polyester foil |
| Keratan rentas konduktor (Data umum) | 4x 2x 0.3 mm² |
| Penutup perisai optik (Data umum) | 65 % |
| Jenis kabel (singkatan) (Data umum) | 94E |
| Diameter kabel luaran D (Data umum) | 8 mm ±0,3 mm |
| Penebat konduktor bahan (Data umum) | Foamed PE |
| Suhu ambien (operasi) (Data umum) | -20 °C ... 80 °C (Cable) |
| Talian isyarat struktur konduktor (Data umum) | 1x |
| Suhu ambien (pemasangan) (Data umum) | 0 °C ... 50 °C |
| Diameter teras termasuk penebat (Data umum) | 1.45 mm ±0.05 mm |
| Jejari lenturan terkecil, pemasangan tetap (Data umum) | 30 mm |
| Jejari lenturan terkecil, pemasangan boleh alih (Data umum) | 60 mm |
Spesifikasi teknikal dan data prestasi