| Parameter | Nilai |
|---|---|
| GTIN | 4046356472463 |
| Nota | Made to Order (non-returnable) |
| (Kabel) | No hazardous substances above threshold values |
| Kunci Pesanan | 1416236 |
| Halaman katalog | Page 310 (PC-2011) |
| Unit pembungkusan | 1 pc |
| (Data umum) | -40 °C ... 80 °C |
| Negara asal | PL (Poland) |
| RoHS China (Kabel) | Environmentally friendly use period: unlimited = EFUP-e |
| Nombor tarif tersuai | 85444210 |
| Perisai (Data umum) | Tinned copper braided shield |
| Jenis kabel (Data umum) | PROFINET robot CAT5 |
| Atenuasi (Data umum) | 2.9 dB (with 1 MHz) |
| Warna wayar (Data umum) | White, yellow, blue, orange |
| Berat kabel (Data umum) | 55 kg/km |
| Bebas halogen (Data umum) | according to IEC 60754-1 |
| Gaya UL AWM (Data umum) | 20233 (80°C/300 V) |
| Kelainan keseluruhan (Data umum) | Star quad |
| Daya kilasan (Data umum) | ± 180 °/m (1 000 000 torsion cycles) |
| Masa jalan isyarat (Data umum) | 4.8 ns/m |
| Impedans gelombang (Data umum) | 100 Ω ±5 Ω (at 100 MHz) |
| Talian isyarat AWG (Data umum) | 22 |
| Struktur kabel (Data umum) | 1x4xAWG22/19; S/TQ |
| Rintangan gelung (Data umum) | ≤ 120.00 Ω/km |
| Rintangan api (Data umum) | according to IEC 60332-1-2 |
| Rintangan lain (Data umum) | UV resistant According to UL 1581, Section 1200 |
| Rintangan terhadap minyak (Data umum) | in accordance with DIN EN 60811-2-1 |
| Bahan konduktor (Data umum) | Tin-plated Cu litz wires |
| Jenis/kategori isyarat (Data umum) | PROFINET CAT5 (IEC 11801), 100 Mbps |
| Rintangan penebat (Data umum) | ≥ 500 MΩ*km |
| Berat setiap Keping (tidak termasuk pembungkusan) | 142.700 g |
| Sarung luaran, warna (Data umum) | green RAL 6018 |
| Voltan nominal, kabel (Data umum) | 300 V |
| Ketebalan sarung luar (Data umum) | approx. 1 mm |
| Sarung luar, bahan (Data umum) | PUR |
| Teras/Teras voltan ujian (Data umum) | 2000 V (50 Hz, 1 min.) |
| Keratan rentas konduktor (Data umum) | 4x 0.34 mm² |
| Penutup perisai optik (Data umum) | 85 % |
| Teras/Perisai Voltan Ujian (Data Umum) | 2000 V (50 Hz, 1 min.) |
| Jenis kabel (singkatan) (Data umum) | 93R |
| Diameter kabel luaran D (Data umum) | 6.5 mm ±0.2 mm |
| Bilangan kedudukan (Keadaan ambien) | 4 |
| Tahap perlindungan (Data Komersial Utama) | IP20 |
| Penebat konduktor bahan (Data umum) | Foamed PE |
| Suhu ambien (operasi) (Data umum) | -40 °C ... 80 °C |
| Talian isyarat struktur konduktor (Data umum) | 19x 0.15 mm |
| Suhu ambien (pemasangan) (Data umum) | -20 °C ... 60 °C |
| Diameter teras termasuk penebat (Data umum) | 1.5 mm |
| Suhu ambien (penyimpanan/pengangkutan) (Data umum) | -40 °C ... 80 °C |
| Jejari lenturan minimum, pemasangan tetap (Data umum) | 5 x D |