| Parameter | Nilai |
|---|---|
| T2 | |
| Nota | 2011 |
| Jenis | DIN rail module, two-section, divisible |
| Warna | black (RAL 9005) |
| Kedalaman | 65.7 mm (incl. DIN rail 7.5 mm) |
| Lebar | 71 mm |
| Ketinggian | ≤ 2000 m (amsl) |
| Jenis EN | T2 |
| Jenis UL | type 1 |
| Jenis SPD | 1 |
| Jenis produk | Surge protection for NEMA power supply units |
| Benang skru | M5 |
| Jenis pemasangan | DIN rail: 35 mm |
| Kumpulan bahan | I |
| Keluarga produk | VALVETRAB US |
| Nama sambungan | Remote fault indicator contact |
| Voltan nominal | 240/415 V AC (Wye) |
| Semakan artikel | 04 |
| Padang mendatar | 4 Div. |
| Bahan perumahan | PA 6.6 |
| Tahap pencemaran | 2 |
| Panjang pelucutan | 16 mm |
| Kaedah sambungan | Screw connection |
| Kekerapan nominal | 50/60 Hz |
| Arus operasi | 5 mA AC ... 750 mA AC |
| Voltan operasi | 5 V AC ... 250 V AC |
| Kejutan (pembedahan) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Tork pengetatan | 3 Nm (1.5 mm² ... 16 mm²) |
| Cara perlindungan | L-N |
| Voltan nominal UN | 240/415 V AC (TN-S) |
| Fungsi pensuisan | Changeover contact |
| Lukisan dimensi | |
| Arah tindakan | 3L-N & N-GND |
| Bahan penebat | PA 6.6/PBT |
| Bilangan jawatan | 4 |
| Arus operasi AC | 1 A AC |
| Tahap perlindungan | IP20 (only when all terminal points are used) |
| Frekuensi nominal fN | 50 Hz (60 Hz) |
| Kategori voltan lampau | III |
| Nilai CTI bahan | 600 |
| Masa tindak balas tA(LN) | ≤ 25 ns |
| Piawaian/peraturan | EN 60664-1 / EN 61643-11 |
| Getaran (operasi) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
| Masa tindak balas tA(L-PE) | ≤ 100 ns |
| Masa tindak balas tA(N-PE) | ≤ 100 ns |
| Sistem bekalan kuasa IEC | TN-S |
| Pengelasan ujian IEC | II |
| Tingkah laku TOV di UT(LN) | 415 V AC (5 s / withstand mode) |
| Piawaian/spesifikasi | IEC 61643-11 |
| Tingkah laku TOV di UT(N-PE) | 1200 V AC (200 ms / withstand mode) |
| Sistem pengagihan kuasa | Wye |
| Voltan baki Ures(LN) | ≤ 1.8 kV (at In) |
| Keratan rentas konduktor AWG | 15 ... 2 |
| Voltan baki Ures (L-PE) | ≤ 2.2 kV (at In) |
| Voltan baki Ures (N-PE) | ≤ 0.4 kV (at In) |
| Arus nyahcas nominal Masuk | 20 kA |
| Keratan rentas konduktor tegar | 1.5 mm² ... 35 mm² |
| Mesej kerosakan perlindungan lonjakan | Optical, remote indicator contact |
| Suhu ambien (operasi) | -40 °C ... 80 °C |
| Arus Lonjakan Maksimum setiap Fasa | 40 kA |
| Keratan rentas konduktor fleksibel | 1.5 mm² ... 25 mm² |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % |
| Tahap perlindungan voltan Naik (LN) | ≤ 1.8 kV |
| Tahap perlindungan voltan Naik (L-PE) | ≤ 2.2 kV |
| Tahap perlindungan voltan Naik (N-PE) | ≤ 1.5 kV |
| Penarafan arus litar pintas ISCCR | 25 kA |
| Fius sandaran maksimum dengan pendawaian cabang | 125 A (gG) |
| Kadaran arus litar pintas (SCCR) | 200 kA |
| Penarafan perlindungan voltan VPR (LG) | 2000 V |
| Penarafan perlindungan voltan VPR (LL) | 2500 V |
| Penarafan perlindungan voltan VPR (LN) | 1500 V |
| Penarafan perlindungan voltan VPR (NG) | 1200 V |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Arus nyahcas nominal In(8/20) µs | 20 kA |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 80 °C |
| Arus nyahcas maksimum Imax(8/20) µs | 40 kA |
| Ikut penarafan gangguan semasa Ifi(N-PE) | 100 A (305 V AC) |
| Voltan operasi berterusan maksimum UC(LN) | 385 V AC |
| Voltan operasi berterusan maksimum UC(L-PE) | 385 V AC |
| Voltan operasi berterusan maksimum UC(N-PE) | 305 V AC |
| Voltan operasi berterusan maksimum MCOV (LG) | 385 V AC |
| Voltan operasi berterusan maksimum MCOV (LL) | 750 V AC |
| Voltan operasi berterusan maksimum MCOV (LN) | 385 V AC |
| Voltan operasi berterusan maksimum MCOV (NG) | 305 V AC |
Spesifikasi teknikal dan data prestasi