| Parameter | Nilai |
|---|---|
| Uagn≥ 600 V | |
| Nota | The VAL-SEC-T2-GDT-800DC-P protective plug (Item No..: 1052649) is only to be used in series connection with a VAL-SEC-T2-220DC-P (Item No..: 2907879) or VAL-SEC-T2- 380DC-P (Item No..: 2907880). It is not designed for direct use on mains voltage. |
| Jenis | Male |
| Warna | light gray (RAL 7035) |
| Kedalaman | 59.4 mm |
| Lebar | 11.7 mm |
| Ketinggian | ≤ 6000 m (amsl) |
| Jenis EN | T2 |
| Jenis produk | Replacement plug |
| Jenis pemasangan | on base element |
| Kumpulan bahan | I |
| Keluarga produk | SEC Family |
| Semakan artikel | 01 |
| Padang mendatar | 0.6 Div. |
| Bahan perumahan | PA 6.6-FR 20 % GF |
| Tahap pencemaran | 2 |
| Masa tindak balas tA | ≤ 100 ns |
| Kaedah sambungan | pluggable |
| Kejutan (pembedahan) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Cara perlindungan | (DC+/DC-) - PE |
| Lukisan dimensi | |
| Bahan penebat | PA6.6-FR 20% GF |
| Bilangan jawatan | 1 |
| Tahap perlindungan | IP20 |
| Kategori voltan lampau | III |
| IPE arus baki | ≤ 5 µA |
| Nilai CTI bahan | 600 |
| Voltan baki Ures | ≤ 0.5 kV (at In) |
| Getaran (operasi) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
| Sistem bekalan kuasa IEC | DC |
| Pengelasan ujian IEC | II |
| Piawaian/spesifikasi | IEC 61643-11 |
| Tahap perlindungan voltan Naik | ≤ 1.5 kV |
| Mesej kerosakan perlindungan lonjakan | optical |
| Suhu ambien (operasi) | -40 °C ... 80 °C |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Arus nyahcas nominal In(8/20) µs | 20 kA |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 80 °C |
| Arus nyahcas maksimum Imax(8/20) µs | 40 kA |
| Voltan percikan hadapan gelombang pada 6 kV (1.2/50) µs | ≤ 1.5 kV |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi