| Parameter | Nilai |
|---|---|
| T1 / T2 | |
| Nota | 2011 |
| Jenis | DIN rail module, two-section, divisible |
| Kedalaman | 76.6 mm (incl. DIN rail 7.5 mm) |
| Lebar | 71.2 mm |
| Ketinggian | ≤ 2000 m (amsl) |
| Jenis EN | T1 / T2 |
| Jenis produk | Arrester combination |
| Jenis pemasangan | DIN rail: 35 mm |
| Kumpulan bahan | I |
| Keluarga produk | VALVETRAB MS |
| Buka panel sisi | No |
| Padang mendatar | 4 Div. |
| Bahan perumahan | PA 6.6 |
| Tahap pencemaran | 2 |
| Panjang pelucutan | 10 mm ... 12 mm |
| Kaedah sambungan | Push-in connection |
| Keratan rentas AWG | (converted acc. to IEC) |
| Kejutan (pembedahan) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Cara perlindungan | L-N |
| Voltan nominal UN | 240/415 V AC (TN-S) |
| Lukisan dimensi | |
| Arah tindakan | 3L-N & N-PE |
| Bahan penebat | PA 6.6/PBT |
| Bilangan jawatan | 4 |
| Tahap perlindungan | IP20 (only when all terminal points are used) |
| Frekuensi nominal fN | 50 Hz (60 Hz) |
| Kategori voltan lampau | III |
| IPE arus baki | ≤ 5 µA |
| Nilai CTI bahan | 600 |
| Arus beban dinilai IL | 32 A (at 6 mm²) |
| Masa tindak balas tA(LN) | ≤ 25 ns |
| Getaran (operasi) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
| Masa tindak balas tA(L-PE) | ≤ 100 ns |
| Masa tindak balas tA(N-PE) | ≤ 100 ns |
| Sistem bekalan kuasa IEC | TT |
| Pengelasan ujian IEC | I / II |
| Tingkah laku TOV di UT(LN) | 415 V AC (5 s / withstand mode) |
| Piawaian/spesifikasi | IEC 61643-11 |
| Tingkah laku TOV di UT(L-PE) | 415 V AC (5 s / withstand mode) |
| Tingkah laku TOV di UT(N-PE) | 1200 V AC (200 ms / withstand mode) |
| Voltan baki Ures(LN) | ≤ 1.2 kV (at In) |
| Keratan rentas konduktor AWG | 20 ... 8 |
| Voltan baki Ures (L-PE) | ≤ 2 kV (at In) |
| Voltan baki Ures (N-PE) | ≤ 0.6 kV (at In) |
| Penggunaan kuasa siap sedia PC | ≤ 810 mVA |
| Keratan rentas konduktor tegar | 0.5 mm² ... 10 mm² |
| Mesej kerosakan perlindungan lonjakan | optical |
| Suhu ambien (operasi) | -40 °C ... 85 °C |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % |
| Tahap perlindungan voltan Naik (LN) | ≤ 1.2 kV |
| Tahap perlindungan voltan Naik (L-PE) | ≤ 2 kV |
| Tahap perlindungan voltan Naik (N-PE) | ≤ 1.7 kV |
| Penarafan arus litar pintas ISCCR | 25 kA |
| Fius sandaran maksimum dengan pendawaian cabang | 160 A (gG) |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 85 °C |
| Arus nyahcas maksimum Imax(8/20) µs | 50 kA |
| Ikut penarafan gangguan semasa Ifi(N-PE) | 100 A |
| Jumlah arus nyahcas Itotal(8/20) µs | 50 kA |
| Fius sandaran maksimum dengan pendawaian jenis-V | 32 A (gG - 6 mm²) |
| Jumlah arus nyahcas Itotal(10/350) µs | 50 kA |
| Voltan operasi berterusan maksimum UC(LN) | 335 V AC |
| Arus nyahcas nominal In(8/20) µs (LN) | 12.5 kA |
| Voltan operasi berterusan maksimum UC(L-PE) | 335 V AC |
| Voltan operasi berterusan maksimum UC(N-PE) | 264 V AC |
| Arus nyahcas nominal In(8/20) µs (L-PE) | 12.5 kA |
| Arus nyahcas nominal In(8/20) µs (N-PE) | 50 kA |
| Arus nyahcas impuls (10/350) µs (L-PE), cas | 6.25 As |
| Arus nyahcas impuls (10/350) µs (N-PE), cas | 25 As |
| Arus nyahcas impuls (10/350) µs (LN), cas | 6.25 As |
| Arus nyahcas impuls (10/350) µs (LN), tenaga tentu | 39 kJ/Ω |
| Arus nyahcas impuls (10/350) µs (N-PE), tenaga tentu | 625 kJ/Ω |
| Arus nyahcas impuls (10/350) µs (L-PE), tenaga tentu | 39 kJ/Ω |
| Keratan rentas konduktor, fleksibel, dengan ferrule, dengan sarung plastik | 0.5 mm² ... 6 mm² |
| Keratan rentas konduktor fleksibel, dengan ferrule tanpa sarung plastik | 0.5 mm² ... 10 mm² |
| Arus nyahcas impuls (10/350) µs (L-PE), nilai arus puncak Iimp | 12.5 kA |
| Arus nyahcas impuls (10/350) µs (N-PE), nilai arus puncak Iimp | 50 kA |
| Arus nyahcas impuls (10/350) µs (LN), nilai arus puncak Iimp | 12.5 kA |
Spesifikasi teknikal dan data prestasi