Spesifikasi Utama
:PV T2
Nota:The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Jenis:DIN rail module, two-section, divisible
Warna:jet black RAL 9005
Maklumat Pembekal
Produk: 0
Biasanya dihantar dalam 2-3 hari bekerja
Kualiti Dijamin
Penghantaran Pantas
Sokongan Teknikal

Spesifikasi Teknikal

ParameterNilai
PV T2
NotaThe device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
JenisDIN rail module, two-section, divisible
Warnajet black RAL 9005
Kedalaman65.5 mm
Lebar53.4 mm
Ketinggian≤ 2000 m (amsl (above mean sea level))
Jenis ENT1
Jenis SPD4 (for Type 2 photovoltaic applications)
Reka bentuk SPDCombination type
Voltan nominal875 V AC
Benang skruM2
KebolehcapaianAccessible
Jenis pemasanganDIN rail: 35 mm
Nama sambunganRemote fault indicator contact
Bilangan portOne
Padang mendatar3 Div.
Bahan perumahanPA 6.6-FR
Tahap pencemaran2
Panjang pelucutan7 mm
Kaedah sambunganScrew connection
Arus operasi5 mA AC ... 1.5 A AC
Voltan operasi5 V AC ... 250 V AC
Kejutan (pembedahan)60g (Half sine/11 ms/3x XYZ)
Tork pengetatan0.25 Nm
Cara perlindungan(L+) - (L-)
Fungsi pensuisanPDT contact
Tahap perlindunganIP20 (only when all terminal points are used)
IPE arus baki≤ 20 µA DC
Tingkah laku kegagalan SPDOCM (Open-circuit mode)
Lokasi pemasanganInside
Arus beban dinilai IL80 A
Getaran (operasi)7.5g (5-500 Hz/2.5 h/XYZ)
Pengelasan ujian IECPV T1
Konfigurasi sambunganY configuration
Masa tindak balas tA(L-)-PE≤ 25 ns
Piawaian/spesifikasiEN 50539-11 2013
Sistem pengagihan kuasa1
Masa tindak balas tA(L+) - PE≤ 25 ns
Rintangan penebat Riso> 5 GΩ (at 500 V DC)
Keratan rentas konduktor AWG28 ... 16
Voltan litar terbuka UOCSTC≤ 875 V DC
Masa tindak balas tA(L+) - (L-)≤ 25 ns
Penggunaan kuasa siap sedia PC≤ 25 mVA
Voltan baki Ures(L+) - PE≤ 3.5 kV (at In)
Voltan baki Ures(L-) - PE≤ 3.5 kV (at In)
Mesej kerosakan perlindungan lonjakanOptical, remote indicator contact
Suhu ambien (operasi)-40 °C ... 80 °C
Kelembapan yang dibenarkan (operasi)5 % ... 95 %
Voltan baki Ures(L+) - (L-)≤ 3.5 kV (at In)
Arus operasi berterusan ICPV< 20 µA
Keratan rentas konduktor pepejal maks.1.5 mm²
Keratan rentas konduktor pepejal min.0.14 mm²
Penarafan arus litar pintas ISCPV1000 A
Arus nyahcas nominal (8/20) µs15 kA
Arus nyahcas nominal In(L+) - G20 kA
Arus nyahcas nominal In(L-) - G20 kA
Tahap perlindungan voltan Naik (L+) - PE≤ 3.5 kV
Tahap perlindungan voltan Naik (L-) - PE≤ 3.5 kV
Keratan rentas konduktor fleksibel maks.1.5 mm²
Keratan rentas konduktor min fleksibel.0.14 mm²
Penarafan perlindungan voltan VPR (L-) -G3 kV
Penarafan mudah terbakar mengikut UL 94V-0
Tahap perlindungan voltan Naik (L+) - (L-)≤ 3.5 kV
Penarafan perlindungan voltan VPR (L+) - G3 kV
Suhu ambien (penyimpanan/pengangkutan)-40 °C ... 80 °C
Arus nyahcas nominal In(L+) - (L-)20 kA
Jarak antara bahagian hidup dan bahagian yang dibumikan8 mm
Arus nyahcas maksimum Imax(8/20) µs40 kA
Voltan operasi berterusan maksimum UCPV1050 V DC
Jumlah arus nyahcas Jumlah (8/20) µs40 kA
Penarafan perlindungan voltan VPR (L+) - (L-)3 kV
Jumlah arus nyahcas Jumlah (10/350) µs5 kA
Lokasi pemasangan peranti pemutus sambunganInternal
Arus nyahcas impuls (10/350)˽µs, cas2.5 As
Arus nyahcas nominal In(8/20) µs (L+) - PE15 kA
Arus nyahcas nominal In(8/20) µs (L-) - PE15 kA
Voltan operasi berterusan maksimum MCOV (L+) - G1050 V DC
Voltan operasi berterusan maksimum MCOV (L-) - G1050 V DC
Arus nyahcas maksimum Imax(8/20) µs (L+) - PE40 kA
Arus nyahcas maksimum Imax(8/20) µs (L-) - PE40 kA
Arus nyahcas nominal In(8/20) µs (L+) - (L-)15 kA
Arus nyahcas maksimum Imax(8/20) µs (L+) - (L-)40 kA
Voltan operasi berterusan maksimum MCOV (L+) - (L-)1050 V DC
Arus nyahcas impuls (10/350) µs, nilai puncak tempang5 kA
Arus nyahcas impuls (10/350)˽µs, tenaga tentu6.25 kJ/Ω

Penerangan Produk

Lightning surge / current protection device for isolated and grounded 2-pole photovoltaic 1000V DC direct current systems, for rail mounting, 3-pole base element with remote indication contact, three
Ciri-ciri Utama
  • Kualiti gred industri
  • Patuh RoHS
  • Sijil CE
  • Jaminan 1 tahun

Dokumen Produk

Lembaran Data

Spesifikasi teknikal dan data prestasi