

| Parameter | Nilai |
|---|---|
| PV T2 | |
| Nota | The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area. |
| Jenis | DIN rail module, two-section, divisible |
| Warna | jet black RAL 9005 |
| Kedalaman | 65.5 mm |
| Lebar | 53.4 mm |
| Ketinggian | ≤ 2000 m (amsl (above mean sea level)) |
| Jenis SPD | 4 (for Type 2 photovoltaic applications) |
| Reka bentuk SPD | Voltage-limiting type |
| Voltan nominal | 670 V AC |
| Benang skru | M2 |
| Kebolehcapaian | Accessible |
| Jenis pemasangan | DIN rail: 35 mm |
| Nama sambungan | Remote fault indicator contact |
| Bilangan port | One |
| Padang mendatar | 3 Div. |
| Bahan perumahan | PA 6.6-FR |
| Tahap pencemaran | 2 |
| Panjang pelucutan | 7 mm |
| Kaedah sambungan | Screw connection |
| Arus operasi | 5 mA AC ... 1.5 A AC |
| Voltan operasi | 5 V AC ... 250 V AC |
| Kejutan (pembedahan) | 60g (Half sine/11 ms/3x XYZ) |
| Tork pengetatan | 0.25 Nm |
| Cara perlindungan | (L+) - (L-) |
| Fungsi pensuisan | PDT contact |
| Tahap perlindungan | IP20 (only when all terminal points are used) |
| IPE arus baki | ≤ 20 µA DC |
| Tingkah laku kegagalan SPD | OCM (Open-circuit mode) |
| Lokasi pemasangan | Inside |
| Arus beban dinilai IL | 80 A |
| Getaran (operasi) | 7.5g (5-500 Hz/2.5 h/XYZ) |
| Pengelasan ujian IEC | PV T2 |
| Konfigurasi sambungan | Y configuration |
| Masa tindak balas tA(L-)-PE | ≤ 25 ns |
| Piawaian/spesifikasi | EN 50539-11 2013 |
| Sistem pengagihan kuasa | 1 |
| Masa tindak balas tA(L+) - PE | ≤ 25 ns |
| Rintangan penebat Riso | > 5 GΩ (at 500 V DC) |
| Keratan rentas konduktor AWG | 28 ... 16 |
| Voltan litar terbuka UOCSTC | ≤ 670 V DC |
| Masa tindak balas tA(L+) - (L-) | ≤ 25 ns |
| Penggunaan kuasa siap sedia PC | ≤ 20 mVA |
| Voltan baki Ures(L+) - PE | ≤ 2.7 kV (at In) |
| Voltan baki Ures(L-) - PE | ≤ 2.7 kV (at In) |
| Mesej kerosakan perlindungan lonjakan | Optical, remote indicator contact |
| Suhu ambien (operasi) | -40 °C ... 80 °C |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % |
| Voltan baki Ures(L+) - (L-) | ≤ 2.7 kV (at In) |
| Arus operasi berterusan ICPV | 20 µA |
| Keratan rentas konduktor pepejal maks. | 1.5 mm² |
| Keratan rentas konduktor pepejal min. | 0.14 mm² |
| Penarafan arus litar pintas ISCPV | 1000 A |
| Arus nyahcas nominal (8/20) µs | 15 kA |
| Arus nyahcas nominal In(L+) - G | 20 kA |
| Arus nyahcas nominal In(L-) - G | 20 kA |
| Tahap perlindungan voltan Naik (L+) - PE | ≤ 2.7 kV |
| Tahap perlindungan voltan Naik (L-) - PE | ≤ 2.7 kV |
| Keratan rentas konduktor fleksibel maks. | 1.5 mm² |
| Keratan rentas konduktor min fleksibel. | 0.14 mm² |
| Penarafan perlindungan voltan VPR (L-) -G | 2.5 kV |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Tahap perlindungan voltan Naik (L+) - (L-) | ≤ 2.7 kV |
| Penarafan perlindungan voltan VPR (L+) - G | 2.5 kV |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 80 °C |
| Arus nyahcas nominal In(L+) - (L-) | 20 kA |
| Jarak antara bahagian hidup dan bahagian yang dibumikan | 8 mm |
| Arus nyahcas maksimum Imax(8/20) µs | 40 kA |
| Voltan operasi berterusan maksimum UCPV | 800 V DC |
| Jumlah arus nyahcas Jumlah (8/20) µs | 40 kA |
| Penarafan perlindungan voltan VPR (L+) - (L-) | 2.5 kV |
| Lokasi pemasangan peranti pemutus sambungan | Internal |
| Arus nyahcas nominal In(8/20) µs (L+) - PE | 15 kA |
| Arus nyahcas nominal In(8/20) µs (L-) - PE | 15 kA |
| Voltan operasi berterusan maksimum MCOV (L+) - G | 800 V DC |
| Voltan operasi berterusan maksimum MCOV (L-) - G | 800 V DC |
| Arus nyahcas maksimum Imax(8/20) µs (L+) - PE | 40 kA |
| Arus nyahcas maksimum Imax(8/20) µs (L-) - PE | 40 kA |
| Arus nyahcas nominal In(8/20) µs (L+) - (L-) | 15 kA |
| Arus nyahcas maksimum Imax(8/20) µs (L+) - (L-) | 40 kA |
| Voltan operasi berterusan maksimum MCOV (L+) - (L-) | 800 V DC |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi