| Parameter | Nilai |
|---|---|
| T2 | |
| Nota | 2011 |
| Jenis | Male |
| Kedalaman | 67.3 mm |
| Lebar | 17.7 mm |
| Ketinggian | ≤ 2000 m (amsl) |
| Jenis EN | T2 |
| Jenis produk | Replacement plug |
| Jenis pemasangan | on base element |
| Kumpulan bahan | I |
| Keluarga produk | VALVETRAB MS |
| Padang mendatar | 1 Div. |
| Bahan perumahan | PA 6.6 |
| Tahap pencemaran | 2 |
| Masa tindak balas tA | ≤ 25 ns |
| Kejutan (pembedahan) | 30g |
| Cara perlindungan | L-N |
| Voltan nominal UN | 240/415 V AC (TN) |
| Tingkah laku TOV di UT | 480 V AC (5 s / withstand mode) |
| Lukisan dimensi | |
| Arah tindakan | 1L-N/PE |
| Bahan penebat | PA 6.6/PBT |
| Tahap perlindungan | IP20 |
| Frekuensi nominal fN | 50 Hz (60 Hz) |
| Kategori voltan lampau | III |
| IPE arus baki | ≤ 600 µA |
| Nilai CTI bahan | 600 |
| Voltan baki Ures | ≤ 1.8 kV (at In) |
| Piawaian/peraturan | DIN EN 60664-1 / EN 61643-1 |
| Getaran (operasi) | 7.5g |
| Sistem bekalan kuasa IEC | TN |
| Pengelasan ujian IEC | II |
| Piawaian/spesifikasi | IEC 61643-11 |
| Tahap perlindungan voltan Naik | ≤ 1.8 kV |
| Penggunaan kuasa siap sedia PC | ≤ 230 mVA |
| Voltan berterusan maksimum UC | 385 V AC |
| Mesej kerosakan perlindungan lonjakan | optical |
| Suhu ambien (operasi) | -40 °C ... 80 °C |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % |
| Penarafan arus litar pintas ISCCR | 25 kA |
| Fius sandaran maksimum dengan pendawaian cabang | 250 A AC (gG) |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Arus nyahcas nominal In(8/20) µs | 30 kA |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 80 °C |
| Arus nyahcas maksimum Imax(8/20) µs | 65 kA |
| Arus nyahcas impuls (10/350) µs, cas | 1.25 As |
| Arus nyahcas impuls (10/350) µs, nilai puncak tempang | 2.5 kA |
| Arus nyahcas impuls (10/350) µs, tenaga tentu | 1.56 kJ/Ω |