| Parameter | Nilai |
|---|---|
| IP20 (only when all terminal points are used) | |
| Jenis | DIN rail module, two-section, divisible |
| Warna | black |
| Kedalaman | 77.5 mm |
| Lebar | 53.4 mm |
| Ketinggian | ≤ 2000 m (amsl (above mean sea level)) |
| Jenis EN | T2 |
| Benang skru | M5 |
| Jenis pemasangan | DIN rail: 35 mm |
| UT (kalis TOV) | 480 V AC (5 s / L-N) |
| Nama sambungan | Remote fault indicator contact |
| Padang mendatar | 3 Div. |
| Bahan perumahan | PA 6.6 |
| Panjang pelucutan | 16 mm |
| Kaedah sambungan | Screw connection |
| Kejutan (pembedahan) | 30g |
| Tork pengetatan | 4.5 Nm |
| Jenis sambungan IN | Biconnect screw terminal block |
| Voltan nominal UN | 240/415 V AC (TN-C) |
| Fungsi pensuisan | PDT contact |
| Jenis sambungan OUT | Biconnect screw terminal block |
| Arah tindakan | 3L-PEN |
| Tahap perlindungan | IP20 |
| Frekuensi nominal fN | 50 Hz (60 Hz) |
| IPE arus baki | ≤ 1800 µA |
| Arus beban dinilai IL | 80 A |
| Piawaian/peraturan | IEC 61643-11 2011 |
| Getaran (operasi) | 7.5g |
| Masa tindak balas tA(L-PE) | ≤ 25 ns |
| Sistem bekalan kuasa IEC | TN-C |
| Pengelasan ujian IEC | II |
| Voltan baki (L-PEN) | ≤ 1.3 kV |
| Keratan rentas konduktor AWG | 15 ... 2 |
| Arus operasi maksimum Imax | 1.5 A AC (250 V AC) |
| Penggunaan kuasa siap sedia PC | ≤ 690 mVA |
| Mesej kerosakan perlindungan lonjakan | Optical, remote indicator contact |
| Suhu ambien (operasi) | -40 °C ... 80 °C |
| Keratan rentas konduktor AWG maks. | 2 |
| Keratan rentas konduktor AWG min. | 15 |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % |
| Voltan operasi maksimum Umax.AC | 250 V AC |
| Keratan rentas konduktor pepejal maks. | 35 mm² |
| Keratan rentas konduktor pepejal min. | 1.5 mm² |
| Penarafan arus litar pintas ISCCR | 25 kA |
| Tahap perlindungan voltan Naik (L-PEN) | ≤ 1.8 kV |
| Fius sandaran maksimum dengan pendawaian cabang | 250 A AC (gG) |
| Keratan rentas konduktor fleksibel maks. | 25 mm² |
| Keratan rentas konduktor min fleksibel. | 1.5 mm² |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 80 °C |
| Fius sandaran maksimum dengan pendawaian jenis-V | 80 A AC (gG - 16 mm²) |
| Arus nyahcas nominal Dalam(8/20) µs (L-PEN) | 30 kA |
| Voltan operasi berterusan maksimum UC(L-PEN) | 385 V AC |
| Piawaian untuk jarak rambat dan jarak cerapan | EN 60664-1 |
| Arus nyahcas maksimum Imax(8/20) µs maksimum (L-PEN) | 65 kA |
| IP rintangan litar pintas dengan fius sandaran maksimum (berkesan) | 25 kA |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi