| Parameter | Nilai |
|---|---|
| T2 | |
| Nota | 2011 |
| Jenis | DIN rail module, two-section, divisible |
| Warna | light gray (RAL 7035) |
| Kedalaman | 76 mm |
| Lebar | 131.5 mm |
| Ketinggian | ≤ 2000 m (amsl) |
| Jenis EN | T2 |
| Jenis produk | Surge arrester |
| Benang skru | M5 |
| Jenis pemasangan | DIN rail: 35 mm |
| Kumpulan bahan | I |
| Keluarga produk | SEC Family |
| Nama sambungan | Remote fault indicator contact |
| Semakan artikel | 12 |
| Padang mendatar | 7.5 Div. |
| Bahan perumahan | PBT-FR |
| Tahap pencemaran | 2 |
| Panjang pelucutan | 14 mm |
| Kaedah sambungan | Screw connection |
| Arus operasi | 1 mA AC ... 2 A AC |
| Voltan operasi | 250 V AC |
| Tork pengetatan | 3.5 Nm |
| Cara perlindungan | L-N |
| Voltan nominal UN | 240/415 V AC (TN-S) |
| Fungsi pensuisan | Changeover contact |
| Lukisan dimensi | |
| Arah tindakan | 3L-N & N-PE |
| Bahan penebat | PBT-FR |
| Bilangan jawatan | 4 |
| Tahap perlindungan | IP20 |
| Frekuensi nominal fN | 50 Hz (60 Hz) |
| Kategori voltan lampau | III |
| IPE arus baki | ≤ 1 µA |
| Nilai CTI bahan | 600 |
| Masa tindak balas tA(LN) | ≤ 25 ns |
| Masa tindak balas tA(L-PE) | ≤ 100 ns |
| Masa tindak balas tA(N-PE) | ≤ 100 ns |
| Sistem bekalan kuasa IEC | TN-S |
| Pengelasan ujian IEC | II |
| Tingkah laku TOV di UT(LN) | 415 V AC (5 s / withstand mode) |
| Piawaian/spesifikasi | IEC 61643-11 |
| Tingkah laku TOV di UT(N-PE) | 1200 V AC (200 ms / withstand mode) |
| Voltan baki Ures(LN) | ≤ 2.3 kV (at In) |
| Keratan rentas konduktor AWG | 18 ... 2 |
| Voltan baki Ures (L-PE) | ≤ 2.5 kV (at In) |
| Voltan baki Ures (N-PE) | ≤ 1.2 kV (at 10 kA) |
| Keratan rentas konduktor tegar | 4 mm² ... 35 mm² |
| Mesej kerosakan perlindungan lonjakan | Optical, remote indicator contact |
| Suhu ambien (operasi) | -25 °C ... 60 °C |
| Keratan rentas konduktor fleksibel | 4 mm² ... 25 mm² |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % |
| Tahap perlindungan voltan Naik (LN) | ≤ 2.5 kV |
| Tahap perlindungan voltan Naik (N-PE) | ≤ 1.7 kV |
| Penarafan arus litar pintas ISCCR | 25 kA |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 80 °C |
| Arus nyahcas maksimum Imax(8/20) µs | 30 kA |
| Ikut penarafan gangguan semasa Ifi(N-PE) | 100 A |
| Fius sandaran maksimum dengan pendawaian jenis-V | 40 A (gG) |
| Voltan operasi berterusan maksimum UC(LN) | 350 V AC |
| Arus nyahcas nominal In(8/20) µs (LN) | 15 kA |
| Voltan operasi berterusan maksimum UC(L-PE) | 350 V AC |
| Voltan operasi berterusan maksimum UC(N-PE) | 264 V AC |
| Arus nyahcas nominal In(8/20) µs (L-PE) | 15 kA |
| Arus nyahcas nominal In(8/20) µs (N-PE) | 20 kA |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi