| Parameter | Nilai |
|---|---|
| Barang | Specifications |
| PFHD | Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.) |
| MTTFD | More than 100 years (Note:Mean time to dangerous failure (in years)) |
| Berat | Net weight: 180 g approxGross weight: 390 g approx |
| Butiran | Controller |
| Produk | Compact Type 4 Safety Beam Sensor |
| Bahan | Enclosure: ABS |
| Nombor Bahagian | ST4-C11 |
| Nama produk | Compact Type 4 Safety Beam Sensor ST4 |
| Kabel pendawaian | Terminal block connector: 0.2 to 1.5 mm2 |
| Voltan kuasa | 24 V DC +10-15 % Ripple P-P 10 % or less |
| Masa tindak balas | OFF response: 25 ms or lessON response: 90 ms or less (auto reset) / 140 ms or less (manual reset) |
| Nombor Produk | ST4-C11 |
| Output tambahan | PNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch)ST4-C11: one outputST4-C12EX: four outputs[PNP output]Maximum source current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and +V)Residual voltage: 2.5 V or less (at 100 mA source current)[NPN output]Maximum sink current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and 0 V)Residual voltage: 2.0 V or less (at 100 mA sink current)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
| Output lampu yang meredam | -(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
| Terminal sambungan | Detachable spring-cage terminal |
| Penggunaan semasa | 100 mA or less (excluding sensor head ST4-Ax) |
| Piawaian yang berkenaan | IEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x. |
| Kepala sensor yang berkenaan | ST4-Ax |
| Pematuhan arahan penandaan CE | Machinery Directive, EMC Directive, RoHS Directive |
| Output tambahan: Mod operasi | OFF when all beams of the connected ST4-Axs are receivedON when one or more beams of the connected ST4-Axs are interrupted |
| Output kawalan (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch)[PNP output]Maximum source current: 200 mAApplied voltage: same as the supply voltage (between control output and +V)Residual voltage: 2.5 V or less (at 200 mA source current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. source current)Load wiring resistance: 3 Ohm or less (between control output and load)[NPN output]Maximum sink current: 200 mAApplied voltage: same as the supply voltage (between control output and 0 V)Residual voltage: 2.0 V or less (at 200 mA sink current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. sink current)Load wiring resistance: 3 Ohm or less (between control output and load)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
| Output tambahan: Litar perlindungan | Incorporated |
| Output lampu yang meredam: Litar perlindungan | Incorporated |
| Rintangan alam sekitar: Kelembapan ambien | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Rintangan alam sekitar: Rintangan kejutan | 300 m/s2acceleration in X, Y and Z directions three times each |
| Rintangan alam sekitar: Suhu ambien | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| Rintangan alam sekitar: Tahap perlindungan | Enclosure: IP40 (IEC)Terminal: IP20 (IEC) |
| Rintangan alam sekitar: Rintangan getaran | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each< |
| Rintangan alam sekitar: Rintangan penebat | 20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure |
| Output kawalan (OSSD 1, OSSD 2): Mod operasi | ON when all beams of the connected ST4-Axs are receivedOFF when one or more beams of the connected ST4-Axs are interruptedOFF during lockout |
| Kepala sensor yang berkenaan: Bilangan sambungan siri | Interference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets) |
| Output kawalan (OSSD1, OSSD2): Litar perlindungan | Incorporated |
| Rintangan alam sekitar: Ketahanan voltan | 1,000 V AC for one min. between all supply terminals connected together and enclosure |