| Parameter | Nilai |
|---|---|
| Barang | Specifications |
| PFHD | 3.25×10-9 |
| MTTFD | 363 years or more |
| Catatan | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years). |
| Butiran | Min. sensing object ø14 mmø0.551 in(10 mm0.394 inbeam pitch) |
| Produk | Safety Light Curtain [Type 4 PLe SIL3] |
| Bahan | Enclosure : Aluminum, Detection surface : Polycarbonate resin and stainless steel (SUS304), Upper cap / lower cap : Nylon |
| Aksesori | SF4B-TR14 (test rod) : 1 pc. |
| Nombor Bahagian | SF4D-F71 |
| Nama produk | Compact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D |
| Keadaan keselamatan | Control output (OSSD 1 / 2) OFF state |
| Voltan kuasa | 24 V DC+20-30 %Ripple P-P 10 % or less (excluding voltage drop due to cable)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline. |
| Nombor Produk | SF4D-F71 |
| Jenis subsistem | Type B (IEC 61508-2) |
| Sambungan kabel | Total length of emitter / receiver can be extended up to 70 m229.659 fteach using optional mating cable (including the lengthof series mating cables)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline. |
| Fungsi meredam | Incorporated (12-core cable) |
| Julat operasi | Short mode : 0.2 to 7 m0.656 to 22.966 ftLong mode : 0.8 to 12 m2.625 to 39.370 ft(selectable by DIP switch)(Note): The operating range is the possible setting distance between the emitter and the receiver. |
| Unsur pemancar | Infrared LED (peak emission wavelength : 850 nm0.0335 mil) |
| Tahap pencemaran | 3 |
| Kaedah penyambungan | By connector |
| Fungsi ganti | Incorporated (12-core cable) |
| Ketinggian pelindung | 710 mm27.953 in(Note): When using as a safety device for a press machine in China, the length from the center of the first beam channel to the center of the last beam channel become to be protective height. |
| Fungsi saling kunci | Incorporated [Manual reset / auto reset (selectable by wiring)] (8-core cable or 12-core cable) |
| Ketinggian operasi | 2,000 m6,561.68 ftor less(Note): Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Fungsi pilihan | Fixed blanking function, floating blanking function, interlock setting function, external device monitoring setting function, auxiliary output settingfunction, application indicator setting function, muting setting function, override setting function, protect function, cable switching function(Note): To use optional functions, the SF4D-TM1 (optional) and Configurator Light Curtain setting software are required. |
| Pencahayaan ambien | Incandescent light : 5,000 ℓx or less at the light-receiving surface |
| Penggunaan semasa | Emitter : 120 mA or lessReceiver : 150 mA or less |
| Objek pengesan minimum | ø14 mmø0.551 inopaque object(Note): When the floating blanking function is used, the size of the minimum sensing object varies. For the detail, refer to the section on Safety distance. |
| Fungsi penjimatan kuasa | Incorporated |
| Fungsi input ujian | Incorporated |
| Bilangan saluran pancaran | 71 |
| Masa tindak balas kegagalan | Within response time (OFF response) |
| Kaedah penyegerakan | Line synchronization / optical synchronization (selectable by DIP switch) |
| Sudut apertur berkesan | ±2.5° or less at a sensing range of 3 m9.843 ftor longer (based on IEC 61496-2) |
| Fungsi pelepas penguncian | Incorporated |
| T1 (selang ujian bukti) | 20 years |
| Piawaian yang berkenaan: China | GB/T 4584 |
| Piawaian yang berkenaan: Jepun | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3 (SIL3) |
| Piawaian yang berkenaan: Eropah | EN ISO 13849-1:2015 (Category 4, PLe), EN 55011, EN 61000-6-2, EN IEC 63000 |
| SFF (Pecahan Kegagalan Selamat) | 99% |
| Fungsi penunjuk aplikasi | Incorporated (only the receiver lights up when optical synchronization is used) |
| HFT (Toleransi Kerosakan Perkakasan) | 1 |
| Output kawalan (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 350 mA・Applied voltage : Same as supply voltage(between control output and +V)・Residual voltage : 2 V or less (source current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less<NPN output selected>・Maximum sink current : 350 mA・Applied voltage : Same as supply voltage(between control output and 0 V)・Residual voltage : 2 V or less (sink current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less |
| Fungsi pencegahan gangguan | <Not connected in series/parallel>・Line synchronization : 2 units or less (auto)・Optical synchronization : 2 units or less (selectable by DIP switch)<Connected in series/parallel>・Series connection : 5 units or less (total number of beam channels 256 or less)・Parallel connection : 3 units or less (total number of beam channels 192 or less)(Note)・Series / parallel connection mixed : 5 units or less (total number of beam channels 144 or less)(Note)(Note): The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. |
| Piawaian yang berkenaan: Amerika Utara | ANSI/UL 61496-1/2 (Type 4),CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2 |
| Fungsi pemantauan peranti luaran | Incorporated (8-core cable or 12-core cable) |
| Berat (Jumlah pemancar dan penerima) | 1,700g approx. |
| Peraturan dan pensijilan yang berkenaan | CE Marking (Machinery Directive, EMC Directive, RoHS Directive) , UKCA Marking (Machinery Regulations, EMC Regulations, RoHS Regulations), TÜV SÜD certification (U.S.A., Canada), OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06, Korea KCs mark |
| Output tambahan (AUX) (Output bukan keselamatan) | PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and +V)・Residual voltage : 2 V or less (source current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)<NPN output selected>・Maximum sink current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and 0 V)・Residual voltage : 2 V or less (sink current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state) |
| Rintangan alam sekitar: Kelembapan ambien | 30 to 85 % RH, Storage : 30 to 95 % RH |
| Rintangan alam sekitar: Rintangan kejutan | 300 m/s2acceleration (30 G approx.) in X, Y, and Z directions three times eachMalfunction resistance 100 m/s2acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each |
| Piawaian yang berkenaan: Piawaian antarabangsa | IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3) |
| Output kawalan (OSSD 1, OSSD 2): Masa tindak balas | OFF response : 10 ms or less (Not connected in series / parallel), 18 ms or less (Connected in series / parallel)(Note 1)ON response : 50 ms or less (Note 2)(Note 3)(Note 1): For response times by number of beams, refer to the Control output (OSSD 1, OSSD 2) OFF response times.(Note 2): Because the control output (OSSD 1, OSSD 2) must be OFF for at least 80 ms, the ON response will be delayed more than 50 ms when the light blocked time is less than 30 ms.(Note 3): When optical synchronization is selected, if the beam axes of both the top end and bottom end are blocked, the ON response speed decreases by as much as 1 sec. |
| Rintangan alam sekitar: Suhu ambien | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage : -25 to +60 ℃-13 to +140 ℉ |
| Rintangan alam sekitar: Tahap perlindungan | IP67, IP65 (IEC), NEMA Type 13 (NEMA 250) |
| Rintangan alam sekitar: Rintangan getaran | 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions for two hours eachMalfunction resistance 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions twenty times each |
| Rintangan alam sekitar: Rintangan penebat | 20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure |
| Output kawalan (OSSD 1, OSSD 2): Mod operasi | ON when all beams are received, OFF when one or more beams are blocked(Also OFF when internal sensor error or synchronization signal error occurs)(Note): The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. |
| Output kawalan (OSSD1, OSSD2): Litar perlindungan | Incorporated |
| Rintangan alam sekitar: Ketahanan voltan | 1,000 V AC for one minute, between all supply terminals connected together and enclosure |
| Output tambahan (AUX) (Output bukan keselamatan): Masa tindak balas | OFF response : 60 ms or less, ON response : 60 ms or less |
| Output tambahan (AUX) (Output bukan keselamatan): Mod operasi | Control output ON : OFF, Control output OFF : ON(Note): The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. |
| Output tambahan (AUX) (Output bukan keselamatan): Litar perlindungan | Incorporated |
| Ketinggian perlindungan: Apabila digunakan sebagai peralatan keselamatan untuk mesin akhbar Cina | 700 mm27.559 in(Note): When using as a safety device for a press machine in China, the length from the center of the first beam channel to the center of the last beam channel become to be protective height. |
Spesifikasi teknikal dan data prestasi