


| Parameter | Nilai |
|---|---|
| Barang | Specifications |
| PFHD | 3.9 × 10-9(Note) Probability of dangerous failure per hour. |
| Kabel | 0.15 mm2(power line: 0.2 mm2) 8-core heat-resistant PVC cable, 5 m16.404 ftlong |
| MTTFD | 100 years or more(Note) Mean time to dangerous failure. |
| Butiran | Min. sensing object ø45 mmø1.772 in(40 mm1.575 inbeam pitch) |
| Produk | Compact Safety Light Curtain[Type4 PLe SIL3] |
| Bahan | Enclosure: Polycarbonate |
| Padang rasuk | 40 mm1.575 in |
| Aksesori | - |
| Nombor Bahagian | SF4B-A44C |
| Nama produk | Compact Safety Light Curtain[Type4 PLe SIL3] SF4B-C |
| Fungsi ELCA | Incorporated (reducing mutual interference automatically) |
| Voltan kuasa | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Masa tindak balas | OFF response: 14 ms or lessON response: 80 to 90 ms |
| Nombor Produk | SF4B-A44C |
| Sambungan kabel | Extension up to total 50 m164.042 ftis possible for 0.2 mm2or more, cable(Note) When the synchronization+ wire (orange) and synchronization- wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2or more shielded twisted pair cable. |
| Fungsi meredam | - |
| Julat operasi | 0.3 to 7m0.984 to 22.966 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| Unsur pemancar | Infrared LED (Peak emission wavelength: 850 nm0.033 mil) |
| Tahap pencemaran | 3 |
| Fungsi ganti | - |
| Ketinggian pelindung | 1,783.4 mm70.212 in |
| Fungsi saling kunci | Incorporated [Manual reset / Auto reset](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
| Ketinggian operasi | 2,000 m6,561.68 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Fungsi pilihan | Fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing(Note) In case of using optional function, the handy-controller SFB-HC is required. |
| Pencahayaan ambien | Incandescent light: 3,500 liter x or less at the light-receiving face |
| Penggunaan semasa | Emitter: 80 mA or lessReceiver: 100 mA or less |
| Objek pengesan minimum | ø 45 mmø 1.772 inopaque object(Note) In case the blanking function is valid, the operation mode is changed. |
| Bilangan saluran pancaran | 44 |
| Fungsi hentian pelepasan | Incorporated |
| Membisukan output tambahan | - |
| Sudut apertur berkesan | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
| Piawaian yang berkenaan: Jepun | JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3 (SIL3) |
| Piawaian yang berkenaan: Eropah | EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| Output kawalan (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 200 mA• Applied voltage: Same as supply voltage (between the control output and +V)• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3 Ω or less• Maximum sink current: 200 mA• Applied voltage: Same as supply voltage (between the control output and 0 V)• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: : 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3 Ω or less |
| Piawaian yang berkenaan: Amerika Utara | ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
| Fungsi pemantauan peranti luaran | Incorporated |
| Output tambahan (Output bukan keselamatan) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and +V)• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m65.617 ftlength cable)• Maximum sink current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m65.617 ftlength cable) |
| Fungsi penunjuk pelbagai guna yang besar | - |
| Membisukan output tambahan: Mod operasi | - |
| Peraturan dan pensijilan yang berkenaan | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
| Rintangan alam sekitar: Kelembapan ambien | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Rintangan alam sekitar: Rintangan kejutan | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions for three times each |
| Meredamkan output tambahan: Litar perlindungan | - |
| Berat bersih (Jumlah pemancar dan penerima) | approx. 2,100 g |
| Piawaian yang berkenaan: Piawaian antarabangsa | IEC 61496-1 / 2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3) |
| Rintangan alam sekitar: Suhu ambien | -10 to +55℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃–3 to +140 ℉ |
| Rintangan alam sekitar: Tahap perlindungan | IP65 (IEC) |
| Rintangan alam sekitar: Rintangan getaran | 10 to 55 Hz frequency, 0.75 mm0.030 inamplitude in X, Y and Z directions for two hours each |
| Rintangan alam sekitar: Rintangan penebat | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Output kawalan (OSSD 1, OSSD 2): Mod operasi | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note) During muting, control output will not turn off even if the beams are interrupted.(Note) When the blanking function is enabled, the operating mode will change. |
| Output kawalan (OSSD1, OSSD2): Litar perlindungan | Incorporated |
| Rintangan alam sekitar: Ketahanan voltan | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Output tambahan (Output bukan keselamatan): Mod operasi | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.) |
| Output tambahan (Output bukan keselamatan): Litar perlindungan | Incorporated |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi