| Parameter | Nilai |
|---|---|
| C2 | |
| Nota | 2018 |
| Jenis | DIN rail module, two-section, divisible |
| Warna | blue (RAL 5015) |
| Kedalaman | 100 mm (incl. DIN rail 7.5 mm) |
| Lebar | 6.2 mm +0.1 mm |
| Ketinggian | ≤ 2000 m (amsl) |
| Jenis produk | Surge protection for MCR technology |
| Benang skru | M3 |
| Jenis pemasangan | DIN rail: TH 35 - 7.5 mm |
| Arus yang dinilai | 600 mA (40 °C) |
| Keluarga produk | TERMITRAB complete |
| Buka panel sisi | No |
| Semakan artikel | 10 |
| Bahan perumahan | PBT |
| Tahap pencemaran | 2 |
| UL, Amerika Syarikat / Kanada | Class I, Div. 2, Groups A, B, C, D T4A |
| Kaedah sambungan | Screw connection |
| Tork pengetatan | 0.5 Nm ... 0.6 Nm |
| Voltan nominal UN | 24 V DC |
| Lukisan dimensi | |
| Arah tindakan | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
| Bahan penebat | PBT |
| Rintangan setiap laluan | 1.65 Ω ±20 % |
| Kapasiti (Teras-Teras) | typ. 2 nF |
| Tahap perlindungan | IP20 |
| Kategori voltan lampau | III |
| IPE arus baki | ≤ 1 µA |
| Arus input maksimum II | 400 mA (T4 / -40 °C ... +50 °C) |
| Voltan input maksimum Ui | 30 V DC |
| Pasangan wayar setiap modul | 1 |
| Pengelasan ujian IEC | C1 |
| Piawaian/spesifikasi | EN 60079-0 |
| Pelemahan input aE, sym. | typ. 0.3 dB (≤ 250 kHz / 150 Ω) |
| Fius sandaran maksimum yang diperlukan | 630 mA (FF) |
| Keratan rentas konduktor AWG | 24 ... 12 |
| Induktans dalaman maksimum Li | negligible |
| Masa tindak balas tA (baris-baris) | ≤ 1 ns |
| Voltan penebat ke bumi | > 180 V DC |
| Kapasitans dalaman maksimum Ci | negligible |
| Masa penetapan semula denyutan (garisan-garisan) | ≤ 700 ms |
| Masa tindak balas tA (garis-bumi) | ≤ 100 ns |
| Keratan rentas konduktor tegar | 0.2 mm² ... 4 mm² |
| Voltan berterusan maksimum UC | 30 V DC |
| Masa penetapan semula denyut (line-earth) | ≤ 30 ms |
| Ketahanan impuls (garis-garis) | C1 - 1 kV / 500 A |
| Mesej kerosakan perlindungan lonjakan | optical |
| Suhu ambien (operasi) | -40 °C ... 70 °C (with current derating) |
| Ketahanan impuls (garis-bumi) | C1 - 1 kV / 500 A |
| Keratan rentas konduktor fleksibel | 0.2 mm² ... 2.5 mm² |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % |
| Arus berkesan operasi ICat UC | ≤ 5 µA |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Tahap perlindungan voltan Naik (talian-talian) | ≤ 55 V (C1 - 1 kV / 500 A) |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 85 °C |
| Tahap perlindungan voltan Naik (line-earth) | ≤ 900 V (C1 - 1 kV / 500 A) |
| Jumlah arus nyahcas Itotal(8/20) µs | 10 kA |
| Tahap perlindungan voltan Upstatic (line-line) | ≤ 50 V (C1 - 1 kV / 500 A) |
| Tahap perlindungan voltan Upstatic (line-earth) | ≤ 900 V (C1 - 1 kV / 500 A) |
| Arus nyahcas nominal In(8/20) µs (garis-garis) | 5 kA |
| Frekuensi potong fg (3 dB), sim. dalam sistem 150 Ω | typ. 940 kHz |
| Arus nyahcas nominal In(8/20) µs (line-ground) | 5 kA |
| Arus nyahcas denyut Iimp(10/350) µs (garis-garis) | 0.5 kA |
| Arus nyahcas denyut Iimp(10/350) µs (line-earth) | 0.5 kA |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi