| Parameter | Nilai |
|---|---|
| 20 V AC | |
| Jenis | Single-level terminal block |
| Lebar | 6.2 mm |
| Ketinggian | 47 mm |
| Panjang | 42.5 mm |
| Jenis produk | Surge protection for MCR technology |
| Benang skru | M3 |
| Jenis pemasangan | DIN rail: 35 mm |
| Arus yang dinilai | 32 A (50 °C) |
| Buka panel sisi | Yes |
| Bahan perumahan | PA |
| Kaedah sambungan | Screw connection |
| Tork pengetatan | 0.8 Nm |
| Voltan nominal UN | 24 V DC |
| Arah tindakan | Line-Earth Ground |
| Bilangan jawatan | 1 |
| Tahap perlindungan | IP20 |
| IPE arus baki | ≤ 5 µA |
| Kapasiti (Teras-Bumi) | ≤ 1.35 nF |
| Piawaian/peraturan | IEC 61643-21 |
| Kelas keperluan VDE | C3 |
| Pengelasan ujian IEC | C3 |
| Keratan rentas konduktor AWG | 24 ... 12 |
| Masa tindak balas tA (garis-bumi) | ≤ 1 ns |
| Keratan rentas konduktor tegar | 0.2 mm² ... 4 mm² |
| Voltan berterusan maksimum UC | 28 V DC |
| Mesej kerosakan perlindungan lonjakan | none |
| Jumlah arus lonjakan (8/20) µs | 169 A |
| Suhu ambien (operasi) | -40 °C ... 85 °C |
| Ketahanan impuls (garis-bumi) | C3 - 25 A |
| Keratan rentas konduktor fleksibel | 0.2 mm² ... 4 mm² |
| Penarafan mudah terbakar mengikut UL 94 | V-2 |
| Voltan baki pada In (konduktor-tanah) | ≤ 55 V |
| Arus nyahcas nominal In(8/20) µs (line-ground) | 169 A (per path) |
| Arus denyut nominal Ian (10/1000) µs (garis-bumi) | 33 A |
| Had voltan output pada lonjakan 1 kV/µs (line-earth) | ≤ 40 V |
| Had voltan output pada 1 kV/µs (line-earth) statik | ≤ 40 V |
| Frekuensi potong fg (3 dB), asimetri (PE) dalam sistem 150 Ω | typ. 1.2 MHz |
| Arus nyahcas maksimum Imax(8/20) µs maksimum (line-earth) | 169 A |