| Parameter | Nilai |
|---|---|
| 2x 400V AC ... 500 V AC ±10% | |
| I/O | asymmetric |
| Keluar | asymmetric 2 kV (Test Severity 3) |
| Kedalaman | 132 mm |
| Lebar | 60 mm |
| Hasil | Typ. 94.53% (3x 400 V AC) |
| tegar | 0.2 mm² ... 4 mm² |
| Warna | Red, Yellow, Green (Multicolor LED) |
| Ketinggian | 135 mm |
| Ditanda | UL/C-UL Listed UL 61010-1 |
| Isyarat | asymmetric 1 kV (Test Severity 3) |
| LED mati | No supply voltage at Input AC (Off) |
| ketegangan | 10 V (Test Severity 3) |
| Penurunan | 60 °C ... 70 °C |
| Kedudukan | 3.x |
| pintu masuk | asymmetric 2 kV (Test Severity 3) |
| fleksibel | 0.2 mm² ... 2.5 mm² |
| fungsi | Visual indication of operating status |
| kekerapan | 50 Hz |
| EN 61010-1 | III (≤ 2000 m) |
| Masa Pendakian | ≤ 1 sec (UOut= 10% ... 90 %) |
| Kriteria A | Normal service behavior within the specified limits. |
| Kriteria B | Transient alteration of service behavior, which is corrected by the device itself. |
| Kriteria C | Temporary adverse effects on performance that are automatically corrected by the equipment or that can be reset by operating the control elements. |
| Pemerhatian | Criterion B |
| Panjang Kupas | 10 mm (rigid/flexible) |
| Tegar (AWG) | 24 ... 12 (Cu) |
| Faktor Puncak | Typ. 1.51 (3x 400 V AC) |
| Jenis Produk | Power supply |
| Menetapkan ketinggian | ≤ 5000 m (> 2000 m, Derating: 10%/1000 m) |
| Status Status | UOut> 21 V DC & IOutN (Closed Contact) |
| Ralat Voltan | 70 % |
| EN 61010-2-201 | III (≤ 2000 m) |
| Keluarga Produk | TRIO POWER |
| Teks Tambahan | Class 3 |
| Jenis sambungan | Push-in connection |
| Julat Frekuensi | 0 kHz ... 2 kHz |
| Riak sisa | Typ. 15 mVPP(with nominal values) |
| Jenis papan tanda | LED DC OK - Operating Signal Status (UN= 24 V DC, IOut= IN) |
| Kapasiti Semasa | max. 100 mA |
| Bilangan fasa | 3,00 |
| Indeks Perlindungan | IP20 |
| Peraturan/Peruntukan | DIN EN 61558-2-16 |
| Jenis pemasangan | Rail mounting |
| Pengosongan berterusan | Yes |
| Penyimpangan peredupan | < 1% (static load change 10% ... 90 %) |
| Fius Input Modul | 3.15 A internal (device protection) |
| Struktur Rangkaian | Star Network (TN, TT, IT (PE)) |
| Bilangan tempoh | 25 periods |
| Kuasa Keluaran (PN) | 480 W |
| Voltan pensuisan | MAX 30 V DC (SELV) |
| Penyerapan semasa | 3x 0.77 A (3x 400 V AC) |
| Jenis perlindungan | I |
| Litar Perlindungan | Protection against transients; Varistor |
| Perlindungan terbina dalam | No |
| Tahap pencemaran | 2 |
| Muat turun hubungi kami | 6 kV (Test Severity 3) |
| Julat Voltan Input | 3x 400V AC ... 500 V AC -20% ... +10% |
| Pengenalpastian Tiang | 3.1 (13), 3.2 (14) |
| Kemalangan (dalam perkhidmatan) | 18 ms, 30g, for each local address (IEC 60068-2-27) |
| Pelaksanaan penutup | Polycarbonate |
| Julat frekuensi (fN) | 50 Hz ... 60 Hz ±10% |
| LED Menyala (Merah), ISHORT | UOutOut > 0.9 x IN(on (red), ISHORTS) |
| Keamatan Medan Ujian | 10 V/m (Test Severity 3) |
| Pelepasan gangguan | Interference emission in accordance with EN 61000-6-3 (residential and commercial areas) and EN 61000-6-4 (industrial areas) |
| LED menyala (hijau), DC OK | UOut> 21 V DC & IOutN (on (green), DC OK) |
| Arahan Voltan Rendah | Compliance with the Low Voltage Directive 2014/35/EU |
| Kedudukan untuk pemasangan | Horizontal rail NS 35, EN 60715 |
| Pelepasan ke udara | 8 kV (Test Severity 3) |
| Pemadaman arus tambahan | < 13 A (25 °C) |
| Voltan Output Nominal | 24 V DC |
| Faktor Kuasa (cos phi) | 0.93 (3x 480 V AC) |
| Getaran (dalam perkhidmatan) | 10 Hz ... 50 Hz, amplitude ±0.2 mm (IEC 60068-2-6) |
| Rintangan gangguan | Immunity to interference according to EN 61000-6-1 (domestic use), EN 61000-6-2 (industrial use) |
| Tahan litar pintas | Yes |
| Denominasi piawai | Safety of power supplies up to 1100 V (isolation distances) |
| Rintangan Peredaran Semula | ≤ 35 V DC |
| Piawaian/Spesifikasi | EN 61000-3-2 |
| Arus Pintas Tanah (PE) | < 3.5 mA |
| Arahan pemasangan | Alignable: horizontal 0 mm, vertical 30 mm |
| LED Menyala (Merah Berkelip) OVP | UOUT> OVP (Over voltage protection) (on (flashing red)) |
| Jarak Pemasangan Atas/Bawah | 50 mm / 50 mm |
| Arus Output Terkadar (IN) | 20 A |
| Penggalak Dinamik (IDyn.Boost) | max. 30 A (5 sec) |
| MTBF (IEC 61709, SN 29500) | > 1100000 h (25 °C) |
| Kuasa Output (PDyn. Boost) | max. 720 W (5 sec) |
| LED Menyala (Kuning), IOut > 90% | UOut> 21 V DC & IOut> 0.9 x IN(on (yellow), IOut> 90%) |
| Julat Voltan Input Nominal | 3x 400V AC ... 500 V AC |
| Pelepasan palsu yang dipancarkan | EN 55016 |
| Jenis Voltan Bekalan | AC |
| Sambungan selari mungkin | Yes, to increase power and redundancy with diode |
| Jarak Pemasangan Kanan/Kiri | 0 mm / 0 mm |
| Voltan Grid Negara Biasa | 3x 400V AC |
| Suhu Ambien (Perkhidmatan) | -25 °C ... 70 °C (> 60 °C Derating: 2.5%/K) |
| Keserasian elektromagnetik | Compliance with EMC Directive 2014/30/EU |
| Kamiran arus masuk (I2t) | < 0.33 A2s |
| Masa Penghubung Kegagalan Rangkaian | Typ. 28 ms (3x 400 V AC) |
| Perlindungan Lonjakan Output (OVP) | ≤ 35 V DC |
| Pelaksanaan elemen sampingan | aluminium |
| Pelesapan Beban Nilai Maksimum | < 27.35 W (3x 480 V AC) |
| Voltan Penebat Input/Output | 4 kV AC (type test) |
| Pelesapan Litar Terbuka Maksimum | < 3.1 W (3x 480 V AC) |
| Kemungkinan sambungan siri | yes, to increase the tension (observe the SELV limit) |
| Pelepasan Gangguan Terjalan | EN 55016 |
| Arahan Perlindungan Alam Sekitar | RoHS Directive 2011/65/EU |
| Penutup jari kaki fleksibel dengan manset plastik | 0.25 mm² ... 1.5 mm² |
| Kelas mudah terbakar mengikut UL 94 | V0 (Housing, terminals) |
| Menukar kenalan (tanpa potensi) | OptoMOS |
| Julat Pelarasan Voltan Output (Uset) | 24 V DC ... 28 V DC (> 24 V DC, limited by power constant) |
| Kuasa Dilesapkan pada Beban Nilai Minimum | < 26.08 W (3x 400 V AC) |
| Suhu Ambien (Penyimpanan/Pengangkutan) | -40 °C ... 85 °C |
| Penutup jari kaki fleksibel tanpa sarung plastik | 0.25 mm² ... 2.5 mm² |
| Kelembapan udara maksimum yang dibenarkan (perkhidmatan) | ≤ 95% (at 25°C, non-condensing) |
| Kuasa minimum yang dilesapkan dalam mod vakum | < 3 W (3x 400 V AC) |
| Suhu ambien (Model yang diuji semasa permulaan) | -40 °C |
| Memilih Fius yang Tepat untuk Perlindungan Kemasukan | 3x 6 A ... 16 A (Characteristic B, C, D, K or comparable) |