| Parameter | Nilai |
|---|---|
| 230 V AC | |
| Keluar | 2 kV (Test Severity 3, Asymmetric) |
| AC OK | AcIn> 0.45 x ACN(ACN= 108 V AC) |
| Kemalangan | 18 ms, 30g, per direction in space (according to IEC 60068-2-27) |
| DC OK | UOUT> 0.9 x UN(UN= 24 V DC) |
| Kedalaman | 53 mm |
| Lebar | 136 mm |
| Hasil | Typ. 90% (120 V AC) |
| Warna | green |
| Ketinggian | 240 mm |
| Ditanda | UL/C-UL Listed UL 61010-1 |
| Isyarat | 2 kV (Test Severity 3, Asymmetric) |
| Lalai | closed |
| Digital | 30 V AC 30 V DC 100 mA |
| ketegangan | 10 V (Test Severity 3) |
| Penurunan | > 40 °C ... 50 °C (1%/K) |
| Diameter | 5.6 mm |
| pintu masuk | 4 kV (Test Severity 3, Asymmetric) |
| Jenis Kunci | M12 Screw Lock |
| kekerapan | 50 Hz |
| EN 61010-1 | III (≤ 2000 m) |
| Fius masuk | 6.3 A (internal (device protection)) |
| Masa Pendakian | ≤ 12 ms (UOUT(10 % ... 90 %)) |
| Kriteria A | Normal service behavior within the specified limits. |
| Kriteria B | Transient alteration of service behavior, which is corrected by the device itself. |
| Kriteria C | Temporary adverse effects on performance that are automatically corrected by the equipment or that can be reset by operating the control elements. |
| Pemerhatian | Criterion A |
| Kodifikasi | s |
| Input/Output | asymmetric |
| Kuasa output | 240 W |
| Jenis Produk | Power supply |
| Menetapkan ketinggian | ≤ 4000 m (> 2000 m, Derating: 10%/1000 m) |
| Ralat Voltan | 70 % |
| Kelas Cuaca | 4K26 (EN 60721-3-4) |
| Keluarga Produk | TRIO POWER |
| Masa Sambungan | < 1 sec |
| Jenis sambungan | M12 Cylindrical Connector |
| Julat Frekuensi | 80 MHz ... 1 GHz |
| Bilangan tiang | 3 |
| Riak sisa | ≤ 10 mVPP |
| Jenis papan tanda | LED |
| Bahan Perumahan | Metal |
| Bilangan fasa | 1,00 |
| Indeks Perlindungan | IP67 |
| Peraturan/Peruntukan | IEC 61010-1 |
| Jenis pemasangan | Wall Mounting |
| Penyimpangan peredupan | < 1% (static load change 10% ... 90 %) |
| Struktur Rangkaian | Star Network (TN, TT, IT (PE)) |
| Bilangan tempoh | 25 periods |
| Voltan Operasi | > 85 V AC |
| Petunjuk Status | 2 x Green LED |
| Julat Frekuensi AC | 50 Hz ... 60 Hz ±10% |
| Penyerapan semasa | 2.3 A (120 V AC) |
| Putuskan voltan | < 85 V AC |
| Jenis perlindungan | I |
| Litar Perlindungan | Protection against transient overvoltages; Varistor |
| Tahap pencemaran | 3 |
| Papan Tanda Penetapan | AC OK |
| Muat turun hubungi kami | 6 kV (Test Severity 3) |
| Julat Voltan Input | 120 V AC ... 240 V AC ±10% |
| Input kuasa nominal | 285 VA |
| Getaran (perkhidmatan) | < 15 Hz, width ±2.5 mm (according to IEC 60068-2-6) |
| Julat frekuensi (fN) | 50 Hz ... 60 Hz ±10% |
| Keamatan Medan Ujian | 10 V/m (Test Severity 3) |
| Pelepasan gangguan | Interference emission in accordance with EN 61000-6-3 (residential and commercial areas) and EN 61000-6-4 (industrial areas) |
| Arahan Voltan Rendah | Compliance with the Low Voltage Directive 2014/35/EU |
| Pengurangan rangsangan statik | > 40 °C ... 50 °C 1 %/K> 50 ... 60 °C 0.22 %/K (UN 230 V AC, PStat.Boost= PNx 1:25) |
| Dengan cat pelindung | No |
| Pemadaman arus tambahan | ≤ 25 A (typical) |
| Voltan Output Nominal | 24 V DC ±1% |
| Rintangan gangguan | Immunity to interference according to EN 61000-6-1 (domestic use), EN 61000-6-2 (industrial use) |
| Tahan litar pintas | Yes |
| Denominasi piawai | Electrical Safety |
| Rintangan Peredaran Semula | ≤ 35 V DC |
| Piawaian/Spesifikasi | EN 61000-3-2 |
| Pelaksanaan perumahan | Aluminum (AlMg3) |
| Arus Pintas Tanah (PE) | < 3.5 mA |
| Arahan pemasangan | Stackable: horizontal 20 mm, vertical up 50 mm, vertical down 100 mm |
| Jarak Pemasangan Atas/Bawah | 50 mm / 100 mm |
| Arus Output Terkadar (IN) | 10 A |
| Penggalak Dinamik (IDyn.Boost) | 15 A (5 sec) |
| MTBF (IEC 61709, SN 29500) | > 850000 h (25 °C) |
| Penggalak Statik (anggaran IBoost) | 12.5 A (UN 230 V AC) |
| Kekuatan dielektrik maksimum | ≤ 300 V AC 15 sec |
| Julat Voltan Input Nominal | 120 V AC ... 240 V AC |
| Pelepasan palsu yang dipancarkan | EN 55016 |
| Jenis Voltan Bekalan | AC |
| Sambungan selari mungkin | Yes, for redundancy and power boost |
| Jarak Pemasangan Kanan/Kiri | 20 mm / 20 mm |
| Voltan Grid Negara Biasa | 120 V AC |
| Suhu Ambien (Perkhidmatan) | -25 °C ... 60 °C |
| Keserasian elektromagnetik | Compliance with EMC Directive 2014/30/EU |
| Kamiran arus masuk (I2t) | < 0.5 A2s |
| Masa Penghubung Kegagalan Rangkaian | > 17 ms (120 V AC) |
| Perlindungan Lonjakan Output (OVP) | ≤ 30 V DC |
| Pelesapan Beban Nilai Maksimum | < 25 W (120 V AC) |
| Voltan Penebat Input/Output | 3 kV AC (type test) |
| Pelesapan Litar Terbuka Maksimum | < 2 W (120 V AC) |
| Kemungkinan sambungan siri | Yes |
| Pelepasan Gangguan Terjalan | EN 55016 |
| Kelembapan udara yang dibenarkan (perkhidmatan) | ≤ 100% (at 25°C, non-condensing) |
| Had voltan arus mati | Typ. 25 A (after 1 ms) |
| Suhu Ambien (Penyimpanan/Pengangkutan) | -40 °C ... 85 °C |
| Kelembapan udara maksimum yang dibenarkan (perkhidmatan) | ≤ 100% (at 25°C, non-condensing) |
| Gangguan radio mengikut EN 55011 | EN 55011 (EN 55022) Class B Application in industry and residential |
| Suhu ambien (Model yang diuji semasa permulaan) | -40 °C |
| Memilih Fius yang Tepat untuk Perlindungan Kemasukan | 6 A ... 16 A (US/CAN: branch circuit protection |
| Voltan gangguan radio mengikut EN 55011 | EN 55011 (EN 55022) Class B Application in industry and residential |
| Kelas mudah terbakar mengikut UL 94 (perumahan/terminal) | V0 |
Spesifikasi teknikal dan data prestasi