| Parameter | Nilai |
|---|---|
| GTIN | 4046356945516 |
| Nota | Made to Order (non-returnable) |
| Kunci Pesanan | 2702077 |
| Halaman katalog | Page 361 (C-6-2017) |
| Kedalaman (Nota) | 330 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 438 mm |
| Ketinggian (Nota) | 178 mm |
| Kapsyen (Nota) | Dimensional drawing |
| (Bekalan kuasa) | 2-wire operation: 32 kbps ... 15.3 Mbps |
| Negara asal | DE (Germany) |
| Nombor tarif tersuai | 85176200 |
| (Keadaan ambien) | 16 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) |
| (Litar pelindung) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Pematuhan (Fungsi) | CE-compliant |
| Antara Muka (Bekalan kuasa) | Ethernet |
| MTTF (Keadaan ambien) | 34 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| Kekebalan hingar (Fungsi) | EN 61000-6-2 |
| Lukisan dimensi (Nota) | |
| Antara Muka 1 (Bekalan kuasa) | Ethernet interface, 10/100Base-T(X) in acc. with IEEE 802.3u |
| Antara Muka 2 (Bekalan kuasa) | SHDSL interface according to ITU-T G.991.2.bis |
| Antara Muka 3 (Bekalan kuasa) | USB 2.0 |
| Bilangan port (Bekalan kuasa) | 12 (2-wire operation) |
| Kekebalan hingar (Dimensi) | EN 61000-6-2 |
| (Piawaian dan Peraturan) | D1 - 1 kA |
| Pengurusan (Antara muka bersiri) | Plug and Play, diagnostics via PSI-CONF software or web-based management (only with managed Ethernet extenders) |
| Julat voltan bekalan (Umum) | 100 V AC ... 240 V AC |
| RoHS China (Litar Pelindung) | Environmentally Friendly Use Period = 50 |
| Berat bersih (Keadaan ambien) | 10900 g |
| REACh SVHC (Litar Pelindung) | Lead 7439-92-1 |
| Pematuhan (Keadaan ambien) | CE-compliant |
| Kaedah sambungan (Bekalan kuasa) | USB Type B |
| Voltan bekalan nominal (Umum) | 230 V AC (50 Hz ... 60 Hz) |
| Getaran (operasi) (Fungsi) | DIN EN 60068-2-6 |
| Tahap perlindungan (Dimensi) | IP20 |
| Protokol yang disokong (Bekalan kuasa) | Transparent protocol for IPv4 and IPv6 |
| Panjang penghantaran (Bekalan kuasa) | < 5 m (only for configuration and diagnostics) |
| Berat setiap Keping (tidak termasuk pembungkusan) | 10,900.000 g |
| Bahan perumahan (Keadaan ambien) | Steel, powder-coated |
| Penggunaan arus biasa (Umum) | < 300 mA (220 V AC) |
| Keserasian elektromagnet (Fungsi) | Conformance with EMC Directive 2014/30/EU |
| Kelajuan penghantaran bersiri (Bekalan kuasa) | 4-wire operation: 64 kbps ... 30 Mbps |
| Pengasingan elektrik (Keadaan ambien) | VCC // Ethernet // DSL (A) // DSL (B) // FE |
| Arus yang dinilai (Piawaian dan Peraturan) | ≤ 380 mA (25 °C) |
| Suhu ambien (operasi) (Dimensi) | 5 °C ... 35 °C (Cabinet temperature) |
| Kelembapan yang dibenarkan (operasi) (Dimensi) | 10 % ... 95 % (non-condensing) |
| Sekatan penggunaan (Data Komersial Utama) | EMC: class A product, see manufacturer's declaration in the download area |
| Kapasiti (garisan-garisan) (Piawaian dan Peraturan) | 55 pF |
| IPE arus baki (Piawaian dan Peraturan) | ≤ 4 µA |
| Rintangan dalam siri (Piawaian dan Peraturan) | 3.3 Ω 20 % |
| Kapasiti (garis-bumi) (Piawaian dan Peraturan) | 7 pF |
| Kelas keperluan VDE (Piawaian dan Peraturan) | B2 |
| Keserasian elektromagnet (Keadaan ambien) | Conformance with EMC Directive 2014/30/EU |
| Pengelasan ujian IEC (Piawaian dan Peraturan) | B2 |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | 0 °C ... 50 °C |
| Pelemahan input aE, sym. (Piawaian dan Peraturan) | |
| Masa tindak balas tA (garisan-garisan) (Piawaian dan Peraturan) | ≤ 100 ns |
| Masa tindak balas tA(line-earth) (Standard dan Peraturan) | ≤ 100 ns |
| Voltan berterusan maksimum UC (Piawaian dan Peraturan) | 185 V DC |
| Ketahanan impuls (garis-garis) (Piawaian dan Peraturan) | C1 - 1 kV/500 A |
| Mesej kerosakan perlindungan lonjakan (Piawaian dan Peraturan) | none |
| Ketahanan impuls (line-earth) (Standard dan Peraturan) | B2 - 4 kV/100 A |
| Antara muka data voltan ujian/bekalan kuasa (Keadaan ambien) | 1.5 kVrms(50 Hz, 1 min.) |
| Semasa operasi ICat UC (Standard dan Peraturan) | ≤ 6 µA |
| Tahap perlindungan voltan Naik (talian-talian) (Piawaian dan Peraturan) | 250 V (B2 - 100 A) |
| Tahap perlindungan voltan Naik (line-earth) (Standard dan Peraturan) | ≤ 580 V (B2 - 100 A) |
| Arus nyahcas denyut Iimp(10/350) µs (Piawaian dan Peraturan) | 2.5 kA (Number of pulses category D1) |
| Jumlah arus nyahcas Itotal(8/20) µs (Piawaian dan Peraturan) | 10 kA |
| Arus nyahcas nominal In(8/20) µs (garis-garis) (Piawaian dan Peraturan) | ≤ 5 kA |
| Arus denyut nominal Ian (10/700) µs (garis-garis) (Piawaian dan Peraturan) | 150 A |
| Frekuensi potong fg (3 dB), sim. dalam sistem 100 Ohm (Piawaian dan Peraturan) | 25 MHz |
| Arus nyahcas nominal In(8/20) µs (line-earth) (Piawaian dan Peraturan) | ≤ 5 kA |
| Arus denyut nominal Ian (10/1000) µs (garis-garis) (Piawaian dan Peraturan) | 100 A |
| Arus denyut nominal Ian (10/700) µs (garis-bumi) (Piawaian dan Peraturan) | 150 A |
| Arus denyut nominal Ian (10/1000) µs (garis-bumi) (Piawaian dan Peraturan) | 100 A |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi