Waktu Perkhidmatan: Isnin hingga Jumaat 9:00-18:00
S8VM-10024 - S8VM-10024 196139 OMRON Power & 100W / 24V / 4.5A Open
Dalam Stok Produk Hangat

S8VM-10024

S8VM-10024 196139 OMRON Power & 100W / 24V / 4.5A Open

$0.00USD
3855 dalam stok
Maklumat Pembekal
OMRON
OMRON
Produk: 41472
Biasanya dihantar dalam 2-3 hari bekerja
Kualiti Dijamin
Penghantaran Pantas
Sokongan Teknikal

Penerangan Produk

More details
Ciri-ciri Utama
  • Kualiti gred industri
  • Patuh RoHS
  • Sijil CE
  • Jaminan 1 tahun

Butiran Teknikal

CJ-Series Analog I/O UnitCJ1W-AD/DA/MADConsistent Microsecond Throughput: Models with Direct Conversion Join the Lineup• Analog Input Units for converting analog input signals into binary data• Analog Output Units for converting binary data into analogoutput signalsCSM_CJ1W-AD_DA_MAD_DS_E_4_1CJ1W-AD042CJ1W-DA042VFeaturesAnalog Input Units• Input up to eight analog signals with one Unit.• Functions include line disconnection detection, averaging, peak value holding, offset/gain adjustment, and scaling. (Offset/gain adjustment is not supported by the CJ1W-AD042. Scaling is supported only by the CJ1W-AD042.)• High-speed A/D conversion in 20 μs/point with direct conversion function * (CJ1W-AD042 only).Analog Output Units• Output up to eight analog signals with one Unit.• Functions include output holding, offset/gain adjustment, and scaling. (Offset/gain adjustment is not supported by the CJ1W-DA042V. Scaling is supported only by the CJ1W-DA08V/DA08C/DA042V.)• High-speed D/A conversion in 20 μs/point with direct conversion function * (CJ1W-DA042V only).Analog I/O Units• Input up to four analog signals and output up to two analog signals with one Unit.• Functions include line disconnection detection, input averaging, scaling, input peak value holding, output holding, ratio conversion, and offset/gain adjustment.* Direct Conversion Instructions for High-speed type can be used to create a consistent response time from input through data processing and output. With the Machine Automation Controller NJ-series, the direct conversion function cannot be used. This function is supported only by the CJ-series CPU Unit.System ConfigurationCPU Unit Analog Input UnitAnalog Output UnitSYSMACRUNAD081-V1DA041CJ1G-CPU44 ERR/ALMRUNRUNPROGRAMMABLE CONTROLLERINH PRPHL COMMERC ERH ADJB1 A1ERC ERH ADJB1 A1OPENMCPWR BUSYMACH No. x10 1x10 0MACH No. x10 1x10 0PERIHERALMODEMODEPORTTemperatureSensorRegulatorPressureSpeedFlow rateVoltagePreampServo- controllerVariable speed controller(Temperature control) M(Position control)MCurrentPowerPower factorTransducerChart recorder(Speed control)SensorNote: The above diagram is an installation example for the CJ1W-AD081-V1 Analog Input Units and CJ1W-DA041 Analog Output Units.1

Dokumen Produk

Lembaran Data

Spesifikasi teknikal dan data prestasi

Manual Pengguna

Panduan pemasangan dan operasi

Top