| Parameter | Nilai |
|---|---|
| Machine building | |
| Nota | The rated insulation voltage applies to insulated cable lugs acc. to DIN 46237:1970-07 with or without path extension and for uninsulated cable lugs acc. to DIN 46234:1980-03 with path extension. |
| Warna | gray (RAL 7042) |
| Lebar | 10 mm |
| Ketinggian | 66 mm |
| Keputusan | Test passed |
| keluaran | (Permanent) |
| Jeneral | Note: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories). |
| Spektrum | Service life test category 1, class B, body mounted |
| Tahap ASD | 1.857 (m/s²)²/Hz |
| Kekerapan | f1= 5 Hz to f2= 150 Hz |
| Potensi | 1 |
| Data jambatan | 41 A / 6 mm² |
| Bentuk denyutan nadi | Half-sine |
| Pecutan | 0.8g |
| Jenis produk | Bolt connection terminal block |
| Benang skru | M5 |
| Julat tork | 2.5 Nm ... 3 Nm |
| Diameter bolt | 5 mm |
| Keratan rentas | 0.5 mm² ... 6 mm² |
| Diameter lubang | 5.3 mm |
| Jenis pemasangan | NS 35/7,5 |
| Arus yang dinilai | 41 A |
| Voltan yang dinilai | 550 V |
| Spesifikasi | DIN EN 50155 (VDE 0115-200):2008-03 |
| Pengenalpastian | II 2 G Ex eb IIC Gb |
| Bilangan baris | 1 |
| Keluarga produk | RT |
| Tempoh kejutan | 30 ms |
| Lebar penutup hujung | 2.2 mm |
| Senarai jambatan | Plug-in bridge / FBS 2-8 / 3030284 |
| Arus nominal | 41 A |
| Voltan nominal | 1000 V |
| Buka panel sisi | Yes |
| Arahan ujian | X-, Y- and Z-axis |
| Semakan artikel | 09 |
| Panjang pelucutan | The stripping length depends on the specification provided by the cable lug manufacturer. |
| Masa pendedahan | 30 s |
| Tork pengetatan | 2.5 ... 3 Nm |
| Rintangan sentuhan | 0.41 mΩ |
| Kedalaman pada NS 35/15 | 58.5 mm |
| Kawasan aplikasi | Railway industry |
| Tahap pencemaran | 3 |
| Kedalaman pada NS 35/7,5 | 51 mm |
| Bahan penebat | PA |
| Voltan lonjakan yang dinilai | 8 kV |
| Arus beban maksimum | 41 A (with 6 mm² conductor cross section) |
| Kategori voltan lampau | III |
| Keratan rentas nominal | 6 mm² |
| Bilangan sambungan | 2 |
| Titik set voltan ujian | 9.8 kV |
| Tempoh ujian setiap paksi | 5 h |
| Kapasiti sambungan AWG | 26 ... 10 |
| Julat keratan rentas AWG | 20 ... 10 (converted acc. to IEC) |
| Rel DIN/sokongan penetapan | NS 35 |
| Peningkatan suhu bekas | 40 K (41 A at 6 mm²) |
| Keratan rentas dinilai AWG | 10 |
| Aksesori yang telah diperakui | 3049097 D-RT 3/5 |
| Voltan penebat yang dinilai | 500 V |
| untuk merapatkan dengan jambatan | 550 V |
| Kapasiti sambungan tegar | 0.1 mm² ... 6 mm² |
| Kumpulan bahan penebat | I |
| Julat suhu operasi | -60 °C ... 110 °C |
| Kapasiti sambungan fleksibel | 0.1 mm² ... 6 mm² |
| Suhu ambien (pemasangan) | -5 °C ... 70 °C |
| Bilangan kejutan setiap arah | 3 |
| Suhu ambien (pengaktifan) | -5 °C ... 70 °C |
| Suhu ambien (operasi) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Bilangan sambungan setiap tahap | 2 |
| Sambungan dalam akaun dengan standard | IEC 60947-7-1 |
| Kelembapan yang dibenarkan (operasi) | 20 % ... 90 % |
| Ujian kenaikan suhu keperluan | Increase in temperature ≤ 45 K |
| Arus tahan masa pendek 6 mm² | 0.72 kA |
| - Pada pemotongan-ke-panjang yang menghubungkan dengan penutup | 220 V |
| Penarafan mudah terbakar mengikut UL 94 | V0 |
| Ketoksikan gas asap NFPA 130 (SMP 800C) | passed |
| Suhu ambien (penyimpanan/pengangkutan) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Kelembapan yang dibenarkan (penyimpanan/pengangkutan) | 30 % ... 70 % |
| Kemudahbakaran permukaan NFPA 130 (ASTM E 162) | passed |
| Warna pengenalan lug kabel cincin: merah | 1 mm² |
| Warna pengenalan lug kabel cincin: biru | 2.5 mm² |
| Penggunaan bahan penebat statik dalam keadaan sejuk | -60 °C |
| Pelesapan kuasa maksimum untuk keadaan nominal | 1.31 W |
| - Pada penyambungan potongan-ke-panjang dengan plat pembahagi | 550 V |
| Pelepasan haba kalorimetrik NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Warna pengenalan lug kabel cincin: kuning | 6 mm² |
| - Pada penghubung antara blok terminal yang tidak bersebelahan | 220 V |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Ketumpatan optik spesifik asap NFPA 130 (ASTM E 662) | passed |
| Indeks suhu bahan penebat relatif (Elec., UL 746 B) | 130 °C |
| Indeks suhu bahan penebat (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi