| Parameter | Nilai |
|---|---|
| PV T2 | |
| Nota | 2011 |
| Jenis | Installation housing |
| Kedalaman | 122 mm |
| Lebar | 250 mm |
| Ketinggian | 370 mm |
| Benang skru | M2 |
| Jenis pemasangan | Surface/Wall mounting |
| Set terdiri daripada | 1774674 PV-CF-S 2,5-6 (+) |
| Bahan penutup | Polycarbonate, transparent |
| Kekuatan impak | IK08 |
| Bahan perumahan | Polycarbonate, glass-fiber-reinforced |
| Tahap pencemaran | 2 |
| Kelas perlindungan | II |
| Arus dinilai IN | 0.5 A |
| Masa tindak balas tA | ≤ 25 ns |
| Panjang pelucutan | 7 mm |
| Kaedah sambungan | MC 1,5/3 |
| Tork pengetatan | 2 lbf-in. ... 4 lbf-in. |
| Keadaan ambien | A, B |
| Arus nominal IN | 24 A DC (total) |
| Voltan nominal UN | 1000 V DC |
| Fungsi pensuisan | Changeover contact, 1-pos. |
| Arah tindakan | (L+)-PE & (L-)-PE & (L+)-(L-) |
| Tahap perlindungan | IP65 |
| Kategori voltan lampau | III |
| IPE arus baki | ≤ 20 µA DC |
| Arus beban dinilai IL | 24 A DC |
| Piawaian/peraturan | EN 50539-11 |
| Tork pengetatan, min | 0.25 Nm |
| Pengelasan ujian IEC | PV T1 |
| Piawaian/spesifikasi | IEC 61439-2 |
| Voltan operasi dinilai Ue | 230 V AC |
| Keratan rentas konduktor AWG | 30 ... 14 (UL) |
| Arus operasi maksimum Imax | 1.5 A AC (250 V AC) |
| Voltan litar terbuka UOCSTC | 830 V DC (Solar generator) |
| Masa tindak balas tA(L+) - (L-) | ≤ 25 ns |
| Masa tindak balas tA(L+/L-) - PE | ≤ 25 ns |
| Arus litar pintas ISCSTC | 8 A DC (per string) |
| Penggunaan kuasa siap sedia PC | ≤ 25 mVA |
| Mesej kerosakan perlindungan lonjakan | Optical, remote indicator contact |
| Suhu ambien (operasi) | -20 °C ... 45 °C |
| Maksimum fius sandaran yang disyorkan | not required |
| Voltan operasi maksimum UmaxDC | 30 V DC |
| Voltan operasi maksimum Umax.AC | 250 V AC |
| Keratan rentas konduktor, tegar maks. | 1.5 mm² |
| Keratan rentas konduktor, min tegar. | 0.14 mm² |
| Fius sandaran maksimum dengan pendawaian cabang | not required |
| Rintangan voltan lonjakan dinilai Uimp | 8 kV |
| Keratan rentas konduktor fleksibel maks. | 1.5 mm² |
| Keratan rentas konduktor min fleksibel. | 0.14 mm² |
| Penarafan mudah terbakar mengikut UL 94 | V2 Gehäuse |
| Arus nyahcas nominal In(8/20) µs | 15 kA |
| Tahap perlindungan voltan Naik (L+) - (L-) | ≤ 3.5 kV |
| Tahap perlindungan voltan Naik (L+/L-) - PE | ≤ 3.5 kV |
| Arus nyahcas maksimum Imax(8/20) µs | 40 kA |
| Voltan operasi berterusan maksimum UCPV | 1000 V DC |
| Jumlah arus nyahcas Itotal(8/20) µs | 40 kA |
| Jumlah arus nyahcas Itotal(10/350) µs | 5 kA |
| Arus nyahcas impuls (10/350) µs, nilai puncak tempang | 5 kA |