| Parameter | Nilai |
|---|---|
| Repeated strong short circuits can reduce the melting integral of the integrated safety fuse. | |
| EMC | to |
| Fius | electronic |
| Kedalaman | 55.6 mm (With 7.5 mm rail) |
| Lebar | 6.2 mm |
| Hasil | > 98.5% |
| Ketinggian | ≤ 3000 m up to 52 °C (amsl) |
| Ditanda | UL/C-UL Listed UL 508 |
| ketegangan | < 5V DC (Low State) |
| Kelembapan | B |
| Bahan | PBT |
| Kandang | to |
| Jenis Tembakan | E (electronic) |
| Getaran | B |
| Pemerhatian | Connection for the signal line tested according to EN 61000-4-4 with 1 kV; If applicable, protective measures should be provided on the client's side |
| Suhu | to |
| Pembinaan | Rail-mounted, one-piece module |
| Jenis Produk | Appliance Protection Switches, Electronic |
| Panjang Nadi | ≥ 50 ms (High) |
| Penurunan voltan | 0.28 V (with 0.5 A) |
| Pemeriksaan kelembapan | 96 h, 95% RH, 40 °C |
| Arus keluaran | max. 0.015 A (Short Circuit Resistant) |
| Voltan keluaran | 24 V DC (Error) |
| Keluarga Produk | PTCB |
| Jenis sambungan | Push-in connection |
| Saluran LED Dimatikan | Off (Channel Off) |
| Voltan nominal | 24 V DC |
| Bilangan tiang | 1 |
| Saluran LED Merah | Ignition (Channel Off, Overvoltage, or Active Undervoltage) |
| Skim Dimensi | |
| Kuasa yang Lesap | Typ. 0.1W (no load) |
| Indeks Perlindungan | IP20 |
| Arus Terkadar IN | 15 A DC (Total Input Current) |
| Peraturan/Peruntukan | EN 61000-6-2 |
| Putuskan Sambungan Lonjakan | ≥ 30.5 V DC (active) |
| Jenis pemasangan | Symmetrical rail: 35 mm |
| Elemen Selamat Gagal | 4 A DC |
| Saluran LED Hijau | On (Channel Connected) |
| Voltan operasi | 10 V DC ... 30 V DC |
| Pra-fius diperlukan | It is only necessary if IMaxof the power supply is > the ability to short circuit. Built-in safety feature. |
| Penyerapan semasa | Typ. 0.4 mA (with 24 V DC) |
| Masa Pemotongan Sambungan | ≤ 600 ms |
| Jenis perlindungan | Iii |
| Bilangan saluran | 1 |
| Arus Rehat I0 | Typ. 3.8 mA |
| Saluran LED Kuning | flashes (Programming Mode On) |
| Tahap pencemaran | 2 |
| Kekuatan Dielektrik | max. 35 V DC (Charging circuit) |
| Julat Voltan Input | 7 V DC ... 30 V DC (Downside Reset) |
| Kemalangan (dalam perkhidmatan) | 30g (IEC 60068-2-27, Ea test) |
| Beban kapasitif maksimum | 5.7 mF (Depending on current setting and available short-circuit current) |
| Penurunan suhu | 15 A (Total current at 60°C) |
| Seksyen Konduktor AWG | 24 ... 12 |
| Arus yang dinilai (pratetap) | 0.5 A |
| Getaran (dalam perkhidmatan) | 10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; according to IEC 60068-2-6, Fc test) |
| Penghad Arus Aktif | Typ. 1.1 x IN |
| Toleransi Pengukuran I | ± 7% |
| Bahagian konduktor tegar | 0.2 mm² ... 2.5 mm² |
| Putuskan voltan bawah | ≤ 9.2 V DC (active) |
| Rintangan Peredaran Semula | max. 35 V DC |
| Panjang untuk dinyahtebat | 8 mm |
| Bahagian konduktor fleksibel | 0.2 mm² ... 2.5 mm² |
| MTBF (IEC 61709, SN 29500) | 27129679 h (at 25°C at 21% load) |
| Masa Permulaan Modul | 40 ms |
| Suhu Ambien (Perkhidmatan) | -30 °C ... 60 °C |
| Voltan Sementara Pengukuran Dimensi | 0.5 kV |
| Keupayaan kerosakan litar pintas | 300 A |
| Kelas mudah terbakar mengikut UL 94 | V-0 |
| Tamat masa selepas memutuskan sambungan saluran | 5 sec (in overload/short circuit) |
| Suhu Ambien (Penyimpanan/Pengangkutan) | -40 °C ... 70 °C |
| Bahagian konduktor fleksibel dengan penutup jari kaki, dengan sarung plastik | 0.25 mm² ... 2.5 mm² |
| Bahagian konduktor fleksibel dengan penutup jari kaki, tanpa sarung plastik | 0.25 mm² ... 2.5 mm² |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi