| Parameter | Nilai |
|---|---|
| Repeated hard short circuits can reduce the melting integral of the integrated backup fuse. | |
| EMC | A |
| Fius | electronic |
| Nota | Connection for signal line tested in accordance with EN 61000-4-4 with 1 kV; if necessary, customer must provide appropriate protective measures |
| Jenis | DIN rail module, one-piece |
| Kedalaman | 55.6 mm (incl. DIN rail 7.5 mm) |
| Lebar | 6.2 mm |
| Ketinggian | ≤ 3000 m up to 52 °C (amsl) |
| Voltan | < 5 V DC (Low state) |
| Kelembapan | B |
| Bahan | PBT |
| Kandang | A |
| Getaran | B |
| Kecekapan | > 98.5 % |
| Suhu | A |
| Jenis produk | Device circuit breakers |
| Panjang denyutan nadi | ≥ 50 ms (High) |
| Penurunan voltan | 0.058 V (at 0.1 A) |
| Ujian kelembapan | 96 h, 95 % RH, 40 °C |
| Jenis pemasangan | DIN rail: 35 mm |
| Voltan yang dinilai | 24 V DC |
| Masa penutupan | ≤ 600 ms |
| Pengenalpastian | UL/C-UL Listed UL 508 |
| Arus keluaran | max. 0.015 A (Short-circuit-proof) |
| Voltan keluaran | 24 V DC (Error) |
| Keluarga produk | PTCB |
| LED saluran dimatikan | off (Channel switched off) |
| LED saluran merah | lit (Channel switched off, over- or undervoltage active) |
| Bilangan saluran | 1 |
| Kaedah tersandung | E (electronic) |
| Tahap pencemaran | 2 |
| Kelas perlindungan | III |
| Arus dinilai IN | 15 A DC (Total current input) |
| Panjang pelucutan | 8 mm |
| LED saluran hijau | lit (Channel switched on) |
| Kaedah sambungan | Push-in connection |
| Keratan rentas AWG | (converted acc. to IEC) |
| Elemen selamat gagal | 4 A DC |
| Voltan operasi | 10 V DC ... 30 V DC |
| Pelesapan kuasa | typ. 0.1 W (No-load operation) |
| Kejutan (pembedahan) | 30g (IEC 60068-2-27, Test Ea) |
| LED saluran kuning | flashing (Programming mode active) |
| Penggunaan semasa | typ. 0.4 mA (at 24 V DC) |
| Kekuatan dielektrik | max. 35 V DC (Load circuit) |
| Lukisan dimensi | |
| Rintangan maklum balas | max. 35 V DC |
| Julat voltan input | 7 V DC ... 30 V DC (Reset with falling edge) |
| Bilangan jawatan | 1 |
| Voltan lonjakan yang dinilai | 0.5 kV |
| Tahap perlindungan | IP20 |
| Beban kapasitif maksimum | 2.35 mF (Depending on the current setting and the short-circuit current available) |
| Fius sandaran yang diperlukan | Only required if Imaxof the power supply > the short-circuit switching capacity. Integrated failsafe element. |
| Penurunan suhu | 15 A (Total current at 60°C) |
| Mengukur toleransi I | ± 17 % |
| Getaran (operasi) | 10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc) |
| Pemadaman voltan lampau | ≥ 30.5 V DC (active) |
| Pemadaman voltan bawah | ≤ 9.2 V DC (active) |
| Piawaian/spesifikasi | EN 61000-6-2 |
| Had arus aktif | typ. 1,2 x IN |
| Arus litar tertutup I0 | typ. 3.8 mA |
| MTBF (IEC 61709, SN 29500) | 28256569 h (at 25 °C with 21 % load) |
| Masa permulaan modul | 40 ms |
| Keratan rentas konduktor AWG | 24 ... 12 |
| Arus yang dinilai (pra-dilaraskan) | 0.1 A |
| Keratan rentas konduktor tegar | 0.2 mm² ... 2.5 mm² |
| Suhu ambien (operasi) | -30 °C ... 60 °C |
| Keratan rentas konduktor fleksibel | 0.2 mm² ... 2.5 mm² |
| Kapasiti pensuisan litar pintas | 300 A |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 70 °C |
| Masa menunggu selepas mematikan saluran | 5 s (at overload / short circuit) |
| Keratan rentas konduktor, fleksibel, dengan ferrule, dengan sarung plastik | 0.25 mm² ... 2.5 mm² |
| Keratan rentas konduktor fleksibel, dengan ferrule tanpa sarung plastik | 0.25 mm² ... 2.5 mm² |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi