| Parameter | Nilai |
|---|---|
| C2 | |
| Nota | Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector. |
| Jenis | DIN rail module, two-section, divisible |
| Warna | black (RAL 9005) |
| Kedalaman | 77.5 mm (incl. DIN rail 7.5 mm) |
| Lebar | 17.7 mm |
| Ketinggian | ≤ 4000 m (amsl) |
| Jenis produk | Surge protection for MCR technology |
| Benang skru | M3 |
| Jenis pemasangan | DIN rail: 35 mm |
| Arus yang dinilai | 700 mA (50 °C) |
| Keluarga produk | PLUGTRAB IQ |
| Buka panel sisi | No |
| Semakan artikel | 08 |
| Padang mendatar | 1 Div. |
| Bahan perumahan | PA 6.6 |
| Tahap pencemaran | 2 |
| Kaedah sambungan | Screw connection |
| Tork pengetatan | 0.5 Nm |
| Voltan nominal UN | 24 V DC |
| Lukisan dimensi | |
| Arah tindakan | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
| Rintangan setiap laluan | 1.2 Ω ±5 % |
| Tahap perlindungan | IP20 |
| Kategori voltan lampau | III |
| IPE arus baki | ≤ 1 µA |
| Kapasiti (Teras-Bumi) | typ. 2 nF |
| Pengelasan ujian IEC | C1 |
| Piawaian/spesifikasi | IEC 61643-21 |
| Fius sandaran maksimum yang diperlukan | 800 mA (FF) |
| Keratan rentas konduktor AWG | 24 ... 12 |
| Pelemahan input aE, asim. | typ. 0.3 dB (≤ 300 kHz / 150 Ω) |
| Masa tindak balas tA (garis-bumi) | ≤ 100 ns |
| Keratan rentas konduktor tegar | 0.2 mm² ... 4 mm² |
| Voltan berterusan maksimum UC | 30 V DC |
| Masa penetapan semula denyut (line-earth) | ≤ 30 ms |
| Mesej kerosakan perlindungan lonjakan | Optical, multi-stage |
| Suhu ambien (operasi) | -40 °C ... 70 °C |
| Ketahanan impuls (garis-bumi) | C1 - 1 kV / 500 A |
| Keratan rentas konduktor fleksibel | 0.2 mm² ... 2.5 mm² |
| Arus berkesan operasi ICat UC | ≤ 1 mA (per path) |
| Masa tindak balas tA (garis isyarat tanah) | ≤ 1 ns |
| Masa penetapan semula denyutan (garisan isyarat tanah) | ≤ 350 ms |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Ketahanan impuls (garis isyarat tanah) | C1 - 1 kV / 500 A |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 85 °C |
| Tahap perlindungan voltan Naik (line-earth) | ≤ 800 V (C1 - 1 kV / 500 A) |
| Jumlah arus nyahcas Itotal(8/20) µs | 20 kA |
| Tahap perlindungan voltan Naik (garis isyarat tanah) | ≤ 75 V (C1 - 1 kV / 500 A) |
| Tahap perlindungan voltan Upstatic (line-earth) | ≤ 80 V (C2 - 10 kV / 5 kA) |
| Arus nyahcas nominal In(8/20) µs (line-ground) | 10 kA |
| Arus nyahcas denyut Iimp(10/350) µs (line-earth) | 2.5 kA |
| Frekuensi potong fg (3 dB), asimetri (pembumian isyarat) dalam sistem 150 Ω | typ. 1.1 MHz |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi