Waktu Perkhidmatan: Isnin hingga Jumaat 9:00-18:00
PT-IQ-1X2-5DC-UT - PT-IQ-1X2-5DC-UT 2800791 PHOENIX CONTACT Surge protection device
Dalam Stok Produk Hangat

PT-IQ-1X2-5DC-UT

PT-IQ-1X2-5DC-UT 2800791 PHOENIX CONTACT Surge protection device

$0.00USD
4636 dalam stok
Spesifikasi Utama
:C2
Nota:Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Jenis:DIN rail module, two-section, divisible
Kedalaman:77.5 mm (incl. DIN rail 7.5 mm)
Maklumat Pembekal
Produk: 0
Biasanya dihantar dalam 2-3 hari bekerja
Kualiti Dijamin
Penghantaran Pantas
Sokongan Teknikal

Spesifikasi Teknikal

ParameterNilai
C2
NotaRemote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
JenisDIN rail module, two-section, divisible
Kedalaman77.5 mm (incl. DIN rail 7.5 mm)
Lebar17.7 mm
Ketinggian≤ 4000 m (amsl)
Jenis produkSurge protection for MCR technology
Benang skruM3
Jenis pemasanganDIN rail: 35 mm
Arus yang dinilai1000 mA (40 °C)
Keluarga produkPLUGTRAB IQ
Padang mendatar1 Div.
Bahan perumahanPA 6.6
Tahap pencemaran2
Kaedah sambunganScrew connection
Tork pengetatan0.5 Nm
Voltan nominal UN5 V DC
Lukisan dimensi
Arah tindakanLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Rintangan setiap laluan1.2 Ω ±5 %
Tahap perlindunganIP20
Kategori voltan lampauIII
IPE arus baki≤ 2 µA (per signal circuit)
Kapasiti (Teras-Bumi)typ. 7.5 nF
Pasangan wayar setiap modul1
Pengelasan ujian IECC1
Piawaian/spesifikasiIEC 61643-21
Pelemahan input aE, sym.typ. 0.3 dB (≤ 40 kHz/150 Ω)
Fius sandaran maksimum yang diperlukan1 A (FF)
Keratan rentas konduktor AWG24 ... 12
Masa tindak balas tA (baris-baris)≤ 1 ns
Masa penetapan semula denyutan (garisan-garisan)≤ 10 ms
Masa tindak balas tA (garis-bumi)≤ 100 ns
Keratan rentas konduktor tegar0.2 mm² ... 4 mm²
Voltan berterusan maksimum UC6 V DC
Masa penetapan semula denyut (line-earth)≤ 10 ms
Ketahanan impuls (garis-garis)C1 - 1 kV / 500 A
Mesej kerosakan perlindungan lonjakanOptical, multi-stage
Suhu ambien (operasi)-40 °C ... 70 °C
Ketahanan impuls (garis-bumi)C1 - 1 kV / 500 A
Keratan rentas konduktor fleksibel0.2 mm² ... 2.5 mm²
Arus berkesan operasi ICat UC≤ 2 mA (in the signal circuit)
Penarafan mudah terbakar mengikut UL 94V-0
Tahap perlindungan voltan Naik (talian-talian)≤ 85 V (C1 - 1 kV / 500 A)
Suhu ambien (penyimpanan/pengangkutan)-40 °C ... 85 °C
Tahap perlindungan voltan Naik (line-earth)≤ 600 V (C1 - 1 kV / 500 A)
Jumlah arus nyahcas Itotal(8/20) µs20 kA
Tahap perlindungan voltan Upstatic (line-line)≤ 26 V (C1 - 1 kV / 500 A)
Arus nyahcas nominal In(8/20) µs (garis-garis)10 kA
Frekuensi potong fg (3 dB), sim. dalam sistem 150 Ωtyp. 300 kHz
Arus nyahcas nominal In(8/20) µs (line-ground)10 kA
Arus nyahcas denyut Iimp(10/350) µs (line-earth)2.5 kA

Penerangan Produk

Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module, for a 2-wire floating signal circuit. Can be used in safety-related circui
Ciri-ciri Utama
  • Kualiti gred industri
  • Patuh RoHS
  • Sijil CE
  • Jaminan 1 tahun

Dokumen Produk

Lembaran Data

Spesifikasi teknikal dan data prestasi