| Parameter | Nilai |
|---|---|
| C2 | |
| ATEX | II 1G Ex ia IIC T4...T6 Ga |
| Nota | A2:2013 |
| Jenis | Male |
| Warna | blue (RAL 5015) |
| Kedalaman | 51.7 mm |
| IECEx | Ex ia IIC T4...T6 Ga |
| Lebar | 17.7 mm |
| Ketinggian | ≤ 2000 m (amsl) |
| Jenis produk | Surge protection for MCR technology |
| Benang skru | M3 |
| Jenis pemasangan | on base element |
| Arus yang dinilai | 500 mA (40 °C) |
| Keluarga produk | PLUGTRAB PT |
| Buka panel sisi | No |
| Semakan artikel | 26 |
| Padang mendatar | 1 Div. |
| Bahan perumahan | PA 6.6 |
| Tahap pencemaran | 2 |
| Kaedah sambungan | Screw connection (in connection with the base element) |
| Tork pengetatan | 0.5 Nm |
| Voltan nominal UN | 24 V DC |
| Lukisan dimensi | |
| Arah tindakan | Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground |
| Bilangan jawatan | 4 |
| Rintangan setiap laluan | 0 Ω |
| kuasa input maksimum Pi | 850.00 mW (T4 / ≤ 80°C) |
| Tahap perlindungan | IP20 |
| Kategori voltan lampau | III |
| IPE arus baki | ≤ 4 µA |
| Kedalaman modul lengkap | 65.5 mm |
| Lebar modul lengkap | 17.7 mm |
| Arus input maksimum II | 500 mA (T4 / ≤ 80°C) |
| Voltan input maksimum Ui | 30 V DC |
| Ketinggian modul lengkap | 90 mm |
| Pengelasan ujian IEC | C1 |
| Piawaian/spesifikasi | EN 61643-21 |
| Pelemahan input aE, sym. | typ. 0.1 dB (≤ 1 MHz / 50 Ω) |
| Fius sandaran maksimum yang diperlukan | 500 mA (T) |
| Keratan rentas konduktor AWG | 24 ... 12 |
| Induktans dalaman maksimum Li | 1 µH |
| Masa tindak balas tA (baris-baris) | ≤ 1 ns |
| Kapasitans dalaman maksimum Ci | 1.1 nF |
| Masa tindak balas tA (garis-bumi) | ≤ 100 ns |
| Keratan rentas konduktor tegar | 0.2 mm² ... 4 mm² |
| Voltan berterusan maksimum UC | 30 V DC |
| Ketahanan impuls (garis-garis) | C1 - 0.5 kV / 250 A |
| Mesej kerosakan perlindungan lonjakan | none |
| Suhu ambien (operasi) | -40 °C ... 80 °C (T4) |
| Ketahanan impuls (garis-bumi) | C1 - 1 kV / 500 A |
| Keratan rentas konduktor fleksibel | 0.2 mm² ... 2.5 mm² |
| Faktor masa dalaman maksimum (Ri/Li) | ≤ 10 µs |
| Arus berkesan operasi ICat UC | ≤ 5 µA |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Tahap perlindungan voltan Naik (talian-talian) | ≤ 60 V (C1 - 500 V / 250 A) |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 85 °C |
| Tahap perlindungan voltan Naik (line-earth) | ≤ 1 kV (C1 - 1 kV / 500 A) |
| Jumlah arus nyahcas Itotal(8/20) µs | 20 kA |
| Voltan baki pada In(konduktor-konduktor) | ≤ 70 V |
| Jumlah arus nyahcas Itotal(10/350) µs | 2 kA |
| Kapasiti daya tampung arus ulang-alik (garis-bumi) | 5 A - 1 s |
| Arus nyahcas nominal In(8/20) µs (garis-garis) | 308 A |
| Frekuensi potong fg (3 dB), simetri dalam sistem 50 Ω | typ. 7 MHz |
| Arus denyut nominal Ian (10/1000) µs (garis-garis) | 59 A |
| Voltan baki dengan Ian (10/1000) µs (garis-garis) | ≤ 65 V |
| Frekuensi potong fg (3 dB), sim. dalam sistem 150 Ω | typ. 2.5 MHz |
| Frekuensi potong fg (3 dB), sim. dalam sistem 600 Ω | typ. 600 kHz |
| Arus nyahcas nominal In(8/20) µs (line-ground) | 10 kA |
| Arus nyahcas denyut Iimp(10/350) µs (line-earth) | 1 kA |
| Had voltan output pada lonjakan 1 kV/µs (garisan-garisan) | ≤ 45 V |
| Had voltan output pada lonjakan 1 kV/µs (line-earth) | ≤ 1 kV |
| Had voltan output pada 1 kV/µs (garisan-garisan) statik | ≤ 45 V |
| Arus nyahcas maksimum Imax(8/20) µs maksimum (garis-garis) | 308 A |
| Had voltan output pada 1 kV/µs (line-earth) statik | ≤ 1 kV |
| Arus nyahcas maksimum Imax(8/20) µs maksimum (line-earth) | 20 kA (in total) |
| Penangkap boleh diuji dengan CHECKMASTER daripada versi perisian: | From SW rev. 1.00 |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi