| Parameter | Nilai |
|---|---|
| GTIN | 4017918996833 |
| Kunci Pesanan | 2981541 |
| Halaman katalog | Page 275 (C-6-2017) |
| Kedalaman (Nota) | 114.5 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 45 mm |
| (Data input) | 68 MW (220 V DC, τ = 0 ms) |
| Ketinggian (Nota) | 112 mm |
| (Data keluaran) | IP54 |
| Negara asal | DE (Germany) |
| boleh pasang (Umum) | Yes |
| Nombor tarif tersuai | 90328900 |
| (Keadaan ambien) | 400 kHz (RJ45) |
| Berat bersih (Data output) | 369.9 g |
| Fius output (Data input) | 6 A gL |
| Jenis geganti (Data output) | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
| Jenis kenalan (Data input) | 4 enabling current paths |
| Kategori (Data sambungan) | 4 |
| Panjang pelucutan (Umum) | 8 mm |
| Kaedah sambungan (Umum) | Spring-cage connection |
| Warna perumah (Data output) | yellow |
| Jenis pemasangan (Data output) | DIN rail mounting |
| (Piawaian dan Peraturan) | No hazardous substances above threshold values |
| Bahan sentuh (Data input) | AgNi10, + 5 µm Au |
| Penetapan (Data sambungan) | EN 62061 |
| Ketinggian maksimum (Dimensi) | max. 2000 m (Above sea level) |
| Jumlah arus persegi (Data input) | 42.25 A2(ITH2= I12+ I22+ I32+ I42) |
| Kedudukan pemasangan (Data output) | any |
| Kategori hentian (Data sambungan) | 0 |
| Tahap perlindungan (Data output) | IP20 |
| Masa pemulihan (Keadaan ambien) | 1 s |
| Arahan pemasangan (Data output) | In rows with zero spacing |
| Arus masuk maksimum (Data input) | 6 A |
| Paparan status (Keadaan ambien) | Green LED |
| Arus masuk, minimum (Data input) | 1 mA |
| Hadkan kekerapan (Keadaan ambien) | 2 kHz (IN1, IN2) |
| Jangka hayat mekanikal (Data input) | > 50x 106cycles |
| Mod operasi nominal (Data output) | 100% operating factor |
| Kapasiti pensuisan minimum (Data input) | 1 mW |
| Berat setiap Keping (tidak termasuk pembungkusan) | 369.900 g |
| RoHS (Piawaian dan Peraturan) China | Environmentally friendly use period: unlimited = EFUP-e |
| Voltan pensuisan maksimum (Data input) | 250 V AC/DC (when the gold layer is destroyed) |
| Voltan pensuisan minimum (Data input) | 100 mV AC/DC |
| Mengehadkan arus berterusan (Data input) | 5 A |
| Tahap prestasi (PL) (Data sambungan) | e |
| Masa pelepasan biasa (Keadaan ambien) | 12 ms |
| Keratan rentas konduktor AWG maks. (Umum) | 16 |
| Keratan rentas konduktor AWG min. (Umum) | 24 |
| Masa tindak balas biasa (Keadaan ambien) | 15 ms |
| Suhu ambien (operasi) (Dimensi) | -20 °C ... 55 °C |
| Keratan rentas konduktor maks. pepejal (Umum) | 1.5 mm² |
| Keratan rentas konduktor min. pepejal (Umum) | 0.2 mm² |
| Voltan input nominal UN (Keadaan ambien) | 24 V DC |
| Sekatan penggunaan (Data Komersial Utama) | EMC: class A product, see manufacturer's declaration in the download area |
| Tahap Integriti Keselamatan (SIL) (Data Sambungan) | 3 |
| Keratan rentas konduktor fleksibel maksimum (Umum) | 1.5 mm² |
| Keratan rentas konduktor min fleksibel (Umum) | 0.2 mm² |
| Penetapan (Data ciri berkaitan keselamatan) | Air clearances and creepage distances between the power circuits |
| Arus input tipikal di UN (Keadaan ambien) | 100 mA |
| Kadaran gangguan (beban ohm) maks. (Data input) | 67 W (24 V DC, τ = 0 ms) |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 70 °C |
| Tahap pencemaran (Data ciri berkaitan keselamatan) | 2 |
| Tahap perlindungan minimum lokasi permulaan (Data output) | IP54 |
| Kategori voltan lampau (Data ciri berkaitan keselamatan) | III |
| Kelembapan maksimum yang dibenarkan (penyimpanan/pengangkutan) (Dimensi) | 75 % (on average, 85% infrequently, non-condensing) |
| Piawaian/peraturan (Data ciri berkaitan keselamatan) | EN 60664/VDE 0110 |
| Julat voltan input merujuk kepada UN (keadaan ambien) | 0.85 ... 1.1 |
| Kelembapan relatif maksimum yang dibenarkan (operasi) (Dimensi) | 75 % (on average, 85% infrequently, non-condensing) |
| Voltan bekalan litar kawalan terkadar AS (Keadaan ambien) | |
| Voltan penebat yang dinilai (Data ciri berkaitan keselamatan) | 250 V |
| Had Tuntutan Tahap Integriti Keselamatan (SIL CL) (Data Sambungan) | 3 |
| Voltan pada litar input/mula dan maklum balas (Keadaan ambien) | 24 V DC |
| Voltan/penebat lonjakan yang dinilai (Data ciri berkaitan keselamatan) | 4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.) |
Spesifikasi teknikal dan data prestasi