| Parameter | Nilai |
|---|---|
| GTIN | 4055626133225 |
| Kunci Pesanan | 2702357 |
| (Lukisan) | |
| Halaman katalog | Page 243 (C-6-2019) |
| Kedalaman (Nota) | 114.5 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 22.5 mm |
| Ketinggian (Nota) | 112.2 mm |
| (Bekalan kuasa) | 2.5 s (MI1, MI2) |
| (Output penggera) | < 150 ms (For Usmanual, monitored start) |
| Tork (Umum) | 0.5 Nm ... 0.6 Nm |
| UNSPSC 11 (ETIM) | 39121501 |
| (Input digital) | 2.5 V DC ... 5 V DC (High) |
| Negara asal | DE (Germany) |
| ETIM 3.0 (eCl@ss) | EC001449 |
| ETIM 4.0 (eCl@ss) | EC001449 |
| ETIM 5.0 (eCl@ss) | EC001448 |
| ETIM 6.0 (eCl@ss) | EC001448 |
| ETIM 7.0 (eCl@ss) | EC001448 |
| Berat bersih (Kali) | 196.3 g |
| Jenis geganti (Masa) | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
| UNSPSC 13.2 (ETIM) | 39122331 |
| UNSPSC 18.0 (ETIM) | 39122331 |
| UNSPSC 19.0 (ETIM) | 39122331 |
| UNSPSC 20.0 (ETIM) | 39122331 |
| UNSPSC 21.0 (ETIM) | 39122331 |
| UNSPSC 6.01 (ETIM) | 30211901 |
| (Input pengukuran) | 5 A (250 V (AC15)) |
| UNSPSC 12.01 (ETIM) | 39121501 |
| boleh pasang (Umum) | Yes |
| Nombor tarif tersuai | 90328900 |
| UNSPSC 7.0901 (ETIM) | 39121501 |
| Warna perumahan (Times) | yellow |
| Jenis pemasangan (Masa) | DIN rail mounting |
| Benang skru (Umum) | M3 |
| Paparan status (Masa) | 2x LED green (OUT1, OUT2) |
| Bahan perumahan (Times) | PBT |
| Nama input (Bekalan kuasa) | Operating mode and monitoring inputs |
| Kedudukan pemasangan (Masa) | vertical or horizontal |
| Kategori (Data sambungan) | 4 |
| Masa penapis (Bekalan kuasa) | max. 2 ms (Test pulse width; low test pulses for operating mode and monitoring inputs) |
| Ketepatan (Input digital) | ± 2 % (in reference to the parameterized limit value) |
| Panjang pelucutan (Umum) | 7 mm |
| Kaedah sambungan (Umum) | Screw connection |
| Nama input (Input digital) | Encoder input |
| (Piawaian dan Peraturan) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Tahap perlindungan (Kali) | IP20 |
| Masa mula semula (Output penggera) | < 1 s (Boot time) |
| eCl@ss 4.0 (Pengelasan) | 27371102 |
| eCl@ss 4.1 (Pengelasan) | 27371102 |
| eCl@ss 5.0 (Pengelasan) | 27371901 |
| eCl@ss 5.1 (Pengelasan) | 27371901 |
| eCl@ss 6.0 (Pengelasan) | 27371800 |
| eCl@ss 7.0 (Pengelasan) | 27371811 |
| eCl@ss 8.0 (Pengelasan) | 27371811 |
| eCl@ss 9.0 (Pengelasan) | 27371811 |
| Arahan pemasangan (Masa) | See derating curve |
| Penetapan (Data sambungan) | EN 62061 |
| Arus masuk (Bekalan kuasa) | < 5 mA |
| Ketinggian maksimum (Dimensi) | ≤ 2000 m (Above sea level) |
| Masa pemulihan (Output penggera) | < 1 s |
| Mod operasi nominal (Kali) | 100% operating factor |
| Fius output (Input pengukur) | 6 A gL/gG |
| Nama output (Input pengukur) | Enabling current path |
| Jenis sentuhan (Input pengukur) | 2 enabling current paths |
| Masa percanggahan (Bekalan kuasa) | 2 s (I1, I2, I3) |
| Arus masuk (Input digital) | < 12 mA |
| Bilangan input (Bekalan kuasa) | 1 (Non-safety-related start input: S34) |
| Kategori hentian (Data sambungan) | 0 |
| Julat masa kelewatan (Output penggera) | 0 s ... 10 s ±10 % (Adjustable switch-on delay for downtime contacts 23/24) |
| Penetapan (Keadaan ambien) | A1/A2 |
| Masa penapis (Keadaan ambien) | 2 ms (at A1 in the event of voltage dips at Us) |
| Bentuk isyarat HTL (Input digital) | 0 V DC ... 3 V DC (Low) |
| Had frekuensi (Input digital) | max. 400 kHz |
| Bentuk isyarat TTL (Input digital) | 0 V DC ... 0.9 V DC (Low) |
| Arus masuk (Input pengukur) | min. 3 mA |
| Bilangan input (Input digital) | 1 (Safety-related encoder input, RJ45) |
| Paparan voltan operasi (Waktu) | 1 x green LED (PWR) |
| Penggunaan semasa (Bekalan kuasa) | typ. 4 mA (at US) |
| Sekatan penggunaan (Lukisan) | EMC: class A product, see manufacturer's declaration in the download area |
| Bahan sentuh (Input pengukur) | AgSnO2 |
| Arus masuk (Keadaan ambien) | < 18 A (Δt = 500 µs at Us) |
| Litar pelindung (Input digital) | 33 V suppressor diode |
| Penggunaan semasa (Input digital) | < 3 mA (Per track for US) |
| Bilangan output (Input pengukur) | 2 (safety-related N/O contacts: 13/14, 23/24) |
| Arus keseluruhan persegi (Input pengukur) | 72 A2(observe derating) |
| Voltan pensuisan (Input pengukur) | min. 12 V AC/DC |
| Berat setiap Keping (tidak termasuk pembungkusan) | 200.000 g |
| (Data ciri berkaitan keselamatan) | Safe isolation, reinforced insulation 6 kV between input circuit (A1/A2, I1, I2, I3, MI1, MI2, IN1, IN2, S34, MO1, MO2, RJ45, USB) and the enabling current paths (13/14, 23/24) |
| Huraian output (Input pengukuran) | 2 NO contacts each in series, without delay, floating |
| Kapasiti pensuisan (Input pengukur) | min. 60 mW |
| RoHS (Piawaian dan Peraturan) China | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Piawaian dan Peraturan) | Lead 7439-92-1 |
| Frekuensi pensuisan (Input pengukuran) | max. 0.5 Hz |
| Penerangan input (Bekalan kuasa) | NPN, IEC 61131-2, type 1 |
| Litar pelindung (Keadaan ambien) | Serial protection against polarity reversal 33 V suppressor diode |
| Tahap prestasi (PL) (Data sambungan) | e (6 A DC1, 17520 switching cycles/year) |
| Bentuk isyarat sinus/kosinus (Input digital) | 2 V DC ... 3 V DC (1 Vppdifferential signal) |
| Penerangan input (Input digital) | TTL, HTL, Sin/Cos |
| Keratan rentas konduktor AWG maks. (Umum) | 12 |
| Keratan rentas konduktor AWG min. (Umum) | 24 |
| Jangka hayat mekanikal (Input pengukur) | 10x 106cycles |
| Kejutan (Data ciri berkaitan keselamatan) | 15g |
| Litar/komponen pelindung (Bekalan kuasa) | 33 V suppressor diode |
| Masa tindak balas biasa di AS (Output penggera) | < 200 ms (For Usautostart) |
| Suhu ambien (operasi) (Dimensi) | -40 °C ... 55 °C (observe derating) |
| Keratan rentas konduktor maks. pepejal (Umum) | 2.5 mm² |
| Keratan rentas konduktor min. pepejal (Umum) | 0.2 mm² |
| Penggunaan kuasa di AS (Keadaan ambien) | typ. 1.78 W |
| Julat arus input isyarat "0" (Bekalan kuasa) | 0 mA ... 1.5 mA |
| Isyarat julat voltan input "0" (Bekalan kuasa) | 0 V DC ... 5 V DC |
| Julat voltan input isyarat "1" (Bekalan kuasa) | 15 V DC ... 30 V DC |
| Arus (Output relay: mendayakan laluan arus) | max. 100 mA |
| Mengehadkan arus berterusan (Mengukur input) | 6 A |
| Tahap Integriti Keselamatan (SIL) (Data Sambungan) | 3 |
| Voltan (Output relay: mendayakan laluan arus) | approx. 22 V DC (Us- 2 V) |
| Keratan rentas konduktor fleksibel maksimum (Umum) | 2.5 mm² |
| Keratan rentas konduktor min fleksibel (Umum) | 0.2 mm² |
| Julat arus input isyarat "0" (Input digital) | 0 mA ... 1.5 mA |
| Isyarat julat voltan input "0" (Input digital) | 0 V DC ... 5 V DC |
| Julat voltan input isyarat "1" (Input digital) | 15 V DC ... 30 V DC |
| Penetapan (Data ciri berkaitan keselamatan) | Air clearances and creepage distances between the power circuits |
| Tahap perlindungan minimum lokasi institusi (Times) | IP54 |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 70 °C |
| Arus bekalan kawalan dinilai IS (Keadaan ambien) | typ. 74 mA |
| Tahap pencemaran (Data ciri berkaitan keselamatan) | 2 |
| Bilangan output (Output relay: mendayakan laluan semasa) | 2 (Non-safety-related signal outputs: MO1, MO2) |
| Huraian output (Output relay: mendayakan laluan semasa) | PNP |
| Kategori voltan lampau (Data ciri berkaitan keselamatan) | III |
| Kelembapan maksimum yang dibenarkan (penyimpanan/pengangkutan) (Dimensi) | 75 % (on average, 85% infrequently, non-condensing) |
| Piawaian/peraturan (Data ciri berkaitan keselamatan) | DIN EN 50178, EN 60947-5-1 |
| Getaran (operasi) (Data ciri berkaitan keselamatan) | 10 Hz ... 150 Hz, 2g |
| Kelembapan relatif maksimum yang dibenarkan (operasi) (Dimensi) | 75 % (on average, 85% infrequently, non-condensing) |
| Rintangan konduktor keseluruhan maksimum yang dibenarkan (Bekalan kuasa) | 150 Ω |
| Voltan bekalan litar kawalan terkadar AS (Keadaan ambien) | 24 V DC -15 % / +10 % (provide external protection) |
| Arus masuk maksimum (Output relay: mendayakan laluan arus) | 500 mA (Δt = 1 ms at Us) |
| Voltan penebat yang dinilai (Data ciri berkaitan keselamatan) | 250 V AC |
| Had Tuntutan Tahap Integriti Keselamatan (SIL CL) (Data Sambungan) | 3 |
| Rintangan konduktor keseluruhan maksimum yang dibenarkan (Input digital) | 150 Ω |
| Perlindungan litar pintas (Output relay: mendayakan laluan arus) | no |
| Kapasiti pensuisan mengikut IEC 60947-5-1 (Input pengukur) | 4 A (24 V (DC13)) |
| Litar/komponen pelindung (Output relay: mendayakan laluan arus) | 33 V suppressor diode |
| Voltan/penebat lonjakan yang dinilai (Data ciri berkaitan keselamatan) | Basic insulation 4 kV between all current paths and housing |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi