| Parameter | Nilai |
|---|---|
| GTIN | 4055626133218 |
| Kunci Pesanan | 2702356 |
| Halaman katalog | Page 276 (C-6-2017) |
| Kedalaman (Nota) | 114.5 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 12.5 mm |
| Ketinggian (Nota) | 116.6 mm |
| Negara asal | DE (Germany) |
| Berat bersih (Kali) | 146.7 g |
| (Input pengukuran) | max. 5 A |
| boleh pasang (Umum) | Yes |
| Nombor tarif tersuai | 85389091 |
| (Keadaan ambien) | Protection against polarity reversal for rated control circuit supply voltage |
| Warna perumahan (Times) | yellow |
| Jenis pemasangan (Masa) | DIN rail mounting |
| Paparan status (Masa) | 4 x LED Bi-Colour |
| Bahan perumahan (Times) | PBT |
| Kedudukan pemasangan (Masa) | vertical or horizontal |
| Kategori (Data sambungan) | 3 |
| Panjang pelucutan (Umum) | 8 mm |
| Kaedah sambungan (Umum) | Spring-cage connection |
| (Piawaian dan Peraturan) | No hazardous substances above threshold values |
| Tahap perlindungan (Kali) | IP20 |
| Arahan pemasangan (Masa) | See derating curve |
| Penetapan (Data sambungan) | EN 62061 |
| Ketinggian maksimum (Dimensi) | max. 2000 m (Above sea level) |
| Masa tindak balas (Output penggera) | typ. 20 ms (at 50 Hz input frequency) |
| Had frekuensi (Bekalan kuasa) | max. 3 kHz (At voltages > 2 VRMS) |
| Mod operasi nominal (Kali) | 100% operating factor |
| Fius output (Input pengukur) | 5 A gL/gG |
| Nama output (Input pengukur) | Enabling current path |
| Jenis sentuhan (Input pengukur) | 1 enabling current path |
| Kategori hentian (Data sambungan) | 0 |
| Julat masa kelewatan (Output penggera) | 0.5 s ... 20 s ±1 % (K1, K2 can be parameterized) |
| Masa penapis (Keadaan ambien) | 1 ms (at A1 in the event of voltage dips at Us) |
| Arus masuk (Input pengukur) | min. 3 mA |
| Penggunaan semasa (Bekalan kuasa) | max. 0.35 mA (at L1/L2/L3) |
| Bahan sentuh (Input pengukur) | AgSnO2 |
| Arus masuk (Keadaan ambien) | 5.6 A (Δt = 400 µs at Us) |
| Isyarat input voltan (Bekalan kuasa) | max. 690 V AC/DC (at L1/L2/L3) |
| Bilangan output (Input pengukur) | 1 (undelayed) |
| Arus keseluruhan persegi (Input pengukur) | 25 A2(observe derating) |
| Voltan pensuisan (Input pengukur) | min. 24 V AC/DC |
| Berat setiap Keping (tidak termasuk pembungkusan) | 146.700 g |
| (Data ciri berkaitan keselamatan) | Safe isolation, reinforced insulation 6 kV:between A1/A2 and 13/14between MO/FO and 13/14Safe isolation, reinforced insulation 8 kV:between L1/L2/L3 and A1/A2between L1/L2/L3 and MO/FObetween L1/L2/L3 and 13/14 |
| Huraian output (Input pengukuran) | safety-related N/O contacts |
| Kapasiti pensuisan (Input pengukur) | min. 72 mW |
| RoHS (Piawaian dan Peraturan) China | Environmentally friendly use period: unlimited = EFUP-e |
| Frekuensi pensuisan (Input pengukuran) | max. 0.5 Hz |
| Litar pelindung (Keadaan ambien) | Surge protection Suppressor diode |
| Tahap prestasi (PL) (Data sambungan) | e (4 A DC13; 5 A AC15; 17520 switching cycles/year) |
| Masa pengambilan biasa di AS (Output penggera) | < 1 s |
| Keratan rentas konduktor AWG maks. (Umum) | 16 |
| Keratan rentas konduktor AWG min. (Umum) | 24 |
| Jangka hayat mekanikal (Input pengukur) | 10x 106cycles |
| Kejutan (Data ciri berkaitan keselamatan) | 15g |
| Suhu ambien (operasi) (Dimensi) | -20 °C ... 55 °C (observe derating) |
| Keratan rentas konduktor maks. pepejal (Umum) | 1.5 mm² |
| Keratan rentas konduktor min. pepejal (Umum) | 0.2 mm² |
| Penggunaan kuasa di AS (Keadaan ambien) | typ. 1.2 W |
| Sekatan penggunaan (Data Komersial Utama) | EMC: class A product, see manufacturer's declaration in the download area |
| Arus (Output relay: mendayakan laluan arus) | max. 100 mA |
| Mengehadkan arus berterusan (Mengukur input) | 5 A (observe derating) |
| Tahap Integriti Keselamatan (SIL) (Data Sambungan) | 3 (4 A DC13; 5 A AC15; 17520 switching cycles/year) |
| Voltan (Output relay: mendayakan laluan arus) | 23 V DC (US- 1 V) |
| Keratan rentas konduktor fleksibel maksimum (Umum) | 1.5 mm² |
| Keratan rentas konduktor min fleksibel (Umum) | 0.2 mm² |
| Pematuhan (Data ciri berkaitan keselamatan) | CE-compliant |
| Penetapan (Data ciri berkaitan keselamatan) | Air clearances and creepage distances between the power circuits |
| Tahap perlindungan minimum lokasi institusi (Times) | IP54 |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 85 °C |
| Arus bekalan kawalan dinilai IS (Keadaan ambien) | typ. 50 mA |
| Tahap pencemaran (Data ciri berkaitan keselamatan) | 2 |
| Bilangan output (Output relay: mendayakan laluan semasa) | 2 (digital, PNP) |
| Kategori voltan lampau (Data ciri berkaitan keselamatan) | III |
| Kelembapan maksimum yang dibenarkan (penyimpanan/pengangkutan) (Dimensi) | 75 % (on average, 85% infrequently, non-condensing) |
| Piawaian/peraturan (Data ciri berkaitan keselamatan) | DIN EN 50178 |
| Getaran (operasi) (Data ciri berkaitan keselamatan) | 10 Hz ...150 Hz, 2g |
| Kelembapan relatif maksimum yang dibenarkan (operasi) (Dimensi) | 75 % (on average, 85% infrequently, non-condensing) |
| Voltan bekalan litar kawalan terkadar AS (Keadaan ambien) | 24 V DC -15 % / +10 % |
| Arus masuk maksimum (Output relay: mendayakan laluan arus) | 500 mA |
| Voltan penebat yang dinilai (Data ciri berkaitan keselamatan) | 250 V AC |
| Had Tuntutan Tahap Integriti Keselamatan (SIL CL) (Data Sambungan) | 3 (4 A DC13; 5 A AC15; 17520 switching cycles/year) |
| Perlindungan litar pintas (Output relay: mendayakan laluan arus) | Yes |
| Voltan/penebat lonjakan yang dinilai (Data ciri berkaitan keselamatan) | Basic insulation 4 kV:between all current paths and housingBasic insulation 8 kV:between L1 and L2between L1 and L3between L2 and L3 |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi