| Parameter | Nilai |
|---|---|
| GTIN | 4046356952491 |
| Kunci Pesanan | 2702097 |
| Halaman katalog | Page 258 (C-6-2017) |
| Kedalaman (Nota) | 114.5 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 12.5 mm |
| Ketinggian (Nota) | 116.6 mm |
| (Bekalan kuasa) | Test pulse rate = 7 x Test pulse width |
| (Output penggera) | < 5 ms (when interrupted via A1; applicative deactivation via A1/A2 is not permitted) |
| (Input digital) | 4 A gL/gG (for low-demand applications) |
| Negara asal | DE (Germany) |
| (Data sambungan) | 1 |
| Berat bersih (Kali) | 126.45 g |
| Jenis geganti (Masa) | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
| boleh pasang (Umum) | Yes |
| Nombor tarif tersuai | 85371098 |
| (Keadaan ambien) | Protection against polarity reversal for rated control circuit supply voltage |
| Warna perumahan (Times) | yellow |
| Jenis pemasangan (Masa) | DIN rail mounting |
| Paparan status (Masa) | 5 x bi-color LED |
| Bahan perumahan (Times) | PBT |
| Kedudukan pemasangan (Masa) | vertical or horizontal |
| Kategori (Data sambungan) | 4 |
| Masa penapis (Bekalan kuasa) | max. 3 ms (at S12, S22, S34; test pulse width) |
| Panjang pelucutan (Umum) | 8 mm |
| Kaedah sambungan (Umum) | Spring-cage connection |
| (Piawaian dan Peraturan) | No hazardous substances above threshold values |
| Tahap perlindungan (Kali) | IP20 |
| Fius output (Input digital) | 6 A gL/gG (N/O contact) |
| Nama output (Input digital) | Enabling current path |
| Masa mula semula (Output penggera) | < 1 s (Boot time) |
| Arahan pemasangan (Masa) | See derating curve |
| Jenis kenalan (Input digital) | 2 enabling current paths |
| Penetapan (Data sambungan) | EN 62061 |
| Arus masuk (Bekalan kuasa) | < 11 mA (with Us/Ixto S12/S22) |
| Ketinggian maksimum (Dimensi) | ≤ 2000 m (Above sea level) |
| Mod operasi nominal (Kali) | 100% operating factor |
| Arus masuk (Input digital) | min. 3 mA |
| Kategori hentian (Data sambungan) | 0 |
| Julat masa kelewatan (Output penggera) | 0.2 s ... 60 s ±5 % (can be set for 27/28) |
| Masa penapis (Keadaan ambien) | 10 ms (For the logic. At A1 in the event of voltage dips at Us) |
| Bahan sentuh (Input digital) | AgSnO2 |
| Penggunaan semasa (Bekalan kuasa) | < 4.1 mA (with Us/Ixto S12/S22) |
| Bilangan output (Input digital) | 1 (undelayed) |
| Jumlah arus persegi (Input digital) | 72 A2(observe derating) |
| Voltan pensuisan (Input digital) | min. 12 V AC/DC |
| Arus masuk (Keadaan ambien) | typ. 25 A (Δt = 10 µs at Us) |
| Huraian output (Input digital) | safety-related N/O contacts |
| Kapasiti pensuisan (Input digital) | min. 60 mW |
| Input kesepadanan 1/2 (Bekalan kuasa) | ∞ |
| Frekuensi pensuisan (Input digital) | 1 Hz |
| Berat setiap Keping (tidak termasuk pembungkusan) | 126.450 g |
| (Data ciri berkaitan keselamatan) | 250 V AC |
| RoHS (Piawaian dan Peraturan) China | Environmentally friendly use period: unlimited = EFUP-e |
| Litar pelindung (Keadaan ambien) | Surge protection Suppressor diode |
| Jangka hayat perkhidmatan mekanikal (Input digital) | 10x 106cycles |
| Tahap prestasi (PL) (Data sambungan) | e |
| Keratan rentas konduktor AWG maks. (Umum) | 16 |
| Keratan rentas konduktor AWG min. (Umum) | 24 |
| Kejutan (Data ciri berkaitan keselamatan) | 15g |
| Masa pelepasan biasa di AS (Output penggera) | < 25 ms (when controlled via S12 (only for undelayed contact 13/14)) |
| Masa tindak balas biasa di AS (Output penggera) | < 35 ms (automatic start) |
| Suhu ambien (operasi) (Dimensi) | -35 °C ... 60 °C (observe derating) |
| Keratan rentas konduktor maks. pepejal (Umum) | 1.5 mm² |
| Keratan rentas konduktor min. pepejal (Umum) | 0.2 mm² |
| Mengehadkan arus berterusan (Input digital) | 6 A (observe derating) |
| Penggunaan kuasa di AS (Keadaan ambien) | typ. 1.44 W |
| Julat arus input isyarat "0" (Bekalan kuasa) | 0 mA ... 2 mA (for safe Off) |
| Isyarat julat voltan input "0" (Bekalan kuasa) | 0 V DC ... 5 V DC (for safe Off) |
| Sekatan penggunaan (Data Komersial Utama) | EMC: class A product, see manufacturer's declaration in the download area |
| Arus (Output relay: mendayakan laluan arus) | max. 100 mA |
| Tahap Integriti Keselamatan (SIL) (Data Sambungan) | 3 |
| Voltan (Output relay: mendayakan laluan arus) | 23 V DC (US- 1 V) |
| Keratan rentas konduktor fleksibel maksimum (Umum) | 1.5 mm² |
| Keratan rentas konduktor min fleksibel (Umum) | 0.2 mm² |
| Pematuhan (Data ciri berkaitan keselamatan) | CE-compliant |
| Penetapan (Data ciri berkaitan keselamatan) | Air clearances and creepage distances between the power circuits |
| Tahap perlindungan minimum lokasi institusi (Times) | IP54 |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 85 °C |
| Arus bekalan kawalan dinilai IS (Keadaan ambien) | typ. 60 mA |
| Tahap pencemaran (Data ciri berkaitan keselamatan) | 2 |
| Bilangan output (Output relay: mendayakan laluan semasa) | 1 (digital, PNP) |
| Huraian output (Output relay: mendayakan laluan semasa) | non-safety-related |
| Kategori voltan lampau (Data ciri berkaitan keselamatan) | III |
| Kelembapan maksimum yang dibenarkan (penyimpanan/pengangkutan) (Dimensi) | 75 % (on average, 85% infrequently, non-condensing) |
| Piawaian/peraturan (Data ciri berkaitan keselamatan) | DIN EN 50178 |
| Getaran (operasi) (Data ciri berkaitan keselamatan) | 10 Hz ...150 Hz, 2g |
| Voltan pada litar input/mula dan suap balik (Bekalan kuasa) | 24 V DC -20 % / +25 % |
| Kelembapan relatif maksimum yang dibenarkan (operasi) (Dimensi) | 75 % (on average, 85% infrequently, non-condensing) |
| Rintangan konduktor keseluruhan maksimum yang dibenarkan (Bekalan kuasa) | 150 Ω |
| Voltan bekalan litar kawalan terkadar AS (Keadaan ambien) | 24 V DC -20 % / +25 % |
| Arus masuk maksimum (Output relay: mendayakan laluan arus) | 500 mA (Δt = 1 ms at Us) |
| Voltan penebat yang dinilai (Data ciri berkaitan keselamatan) | 250 V AC |
| Had Tuntutan Tahap Integriti Keselamatan (SIL CL) (Data Sambungan) | 3 |
| Perlindungan litar pintas (Output relay: mendayakan laluan arus) | Yes |
| Voltan/penebat lonjakan yang dinilai (Data ciri berkaitan keselamatan) | Basic insulation 4 kV: between all current paths and housingSafe isolation, reinforced insulation 6 kV:between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14)between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (27/28)between enabling current paths |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi