| Parameter | Nilai |
|---|---|
| max. 10 s (Boot time) | |
| Nota | G3 |
| Kedalaman | 113.6 mm |
| Kejutan | 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction) |
| Lebar | 22.61 mm |
| Ketinggian | 107.74 mm |
| Semasa | max. 30 mA (Sensor current recording per channel) |
| Kekerapan | 20 Hz (max. recommended sensor signal frequency, as current input) |
| Ketepatan | typ. ± 2 % (as current input, relative to the measuring range final value) |
| boleh pasang | yes |
| Nama input | IN S1, IN S2, IN S3, IN S4 |
| Antaramuka | DIN rail TBUS for connection to the master module, supplied as standard |
| Permohonan | Analog IN |
| Penerangan | Sensor supply voltage per analog input |
| Penamaan | A1/A2 |
| Masa penapis | typ. 5 ms (in the event of voltage dips at Us) |
| Jenis produk | Safety device |
| Masa mula semula | min. 5 s (Boot time) |
| Jenis pemasangan | DIN rail mounting |
| Masa tindak balas | see user manual |
| Kadar pengimbasan | 2.5/5/10/16.6/20/50/60/100/200/400/800/1000/2000/4000 Hz |
| Kategori berhenti | 0 |
| Pengenalpastian | CE-compliant |
| Arus masuk | max. 14 A (Δt = 1 ms at Us) |
| Paparan status | 4x LED (yellow, red) |
| Voltan bekalan | 24 V DC ±3 % |
| Bahan perumahan | Polyamide PA non-reinforced |
| Ketinggian maksimum | ≤ 2000 m (Above sea level) |
| Bilangan input | 4 |
| Kelas perlindungan | III |
| Panjang pelucutan | 10 mm |
| Kaedah sambungan | Push-in connection |
| Kedudukan pemasangan | vertical or horizontal |
| Litar pelindung | Serial protection against polarity reversal |
| Voltan yang dibenarkan | max. 24 V (as current input) |
| Kalis litar pintas | yes |
| Isyarat input semasa | 0 mA ... 25 mA (Measuring range) |
| Tahap perlindungan | IP20 |
| Resolusi (semasa) | 381 nA |
| Resolusi (voltan) | 152 µV |
| Isyarat input voltan | 0 V ... 12 V (Measuring range) |
| Arahan pemasangan | Observe derating |
| Teknologi sambungan | 2-conductor, 3-conductor or 4-conductor (2-conductor sensor signal + 2-conductor sensor supply) |
| Getaran (operasi) | 10 Hz ... 150 Hz, 2g |
| Had frekuensi (3 dB) | 160 Hz (RC low pass, 1st order, as current input) |
| Mod operasi nominal | 100% operating factor |
| Tahap prestasi (PL) | e (2-channel wiring) |
| Penggunaan kuasa di AS | typ. 1.96 W (without sensor supply) |
| Resolusi penukar A/D | 16 bit |
| Penerangan tentang input | Safety-oriented analog inputs, configurable as current or voltage inputs, galvanically isolated |
| Arus maksimum yang dibenarkan | max. 35 mA (as current input) |
| Panjang kabel yang dibenarkan | max. 100 m (per input) |
| Voltan penebat yang dinilai | 250 V AC |
| Pekali suhu | typ. ± 0.07 %/K |
| Paparan voltan operasi | 1 x green LED |
| Keratan rentas konduktor AWG | 24 ... 16 |
| Tahap Integriti Keselamatan (SIL) | 3 |
| Keratan rentas konduktor tegar | 0.2 mm² ... 2.5 mm² |
| Arus input rintangan input | 290 Ω ±25 % (incl. internal protective circuit) |
| Voltan/penebat lonjakan yang dinilai | Basic insulation 4 kV between all current paths and housing |
| Suhu ambien (operasi) | -10 °C ... 70 °C (observe derating) |
| Arus bekalan kawalan dinilai IS | typ. 82 mA (without sensor supply) |
| Keratan rentas konduktor fleksibel | 0.2 mm² ... 2.5 mm² |
| Rintangan input voltan input | 185 kΩ ±25 % |
| Suhu ambien (penyimpanan/pengangkutan) | -20 °C ... 85 °C |
| Voltan bekalan litar kawalan dinilai AS | 19.2 V DC ... 28.8 V DC |
| Nota mengenai teknologi sambungan | shielded |
| Tahap perlindungan minimum lokasi tetap | IP54 |
| Kelembapan maksimum yang dibenarkan (penyimpanan/pengangkutan) | 95 % (non-condensing) |
| Kelembapan relatif maksimum yang dibenarkan (operasi) | 95 % (non-condensing) |
| Pelesapan kuasa maksimum untuk keadaan nominal | 2.76 W (with max. permissible load) |
Spesifikasi teknikal dan data prestasi