| Parameter | Nilai |
|---|---|
| GTIN | 4055626463339 |
| Nota | Made to Order (non-returnable) |
| Kunci Pesanan | 2703021 |
| (Umum) | 42 V DC ... 57 V DC (With UL approval) |
| (Fungsi) | Class I, Div. 2, Groups A, B, C, D |
| Unit pembungkusan | 1 pc |
| (Dimensi) | 2000 m (ATEX approval) |
| ATEX (Fungsi) | II 3 G Ex nA nC IIC T4 Gc X |
| Negara asal | DE (Germany) |
| Isyarat (Fungsi) | ± 1 kV (Data line, asymmetrical) |
| UL, Amerika Syarikat (Fungsi) | UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
| Komen (Fungsi) | Criterion B |
| Nombor tarif tersuai | 85366990 |
| (Keadaan ambien) | Class I, Div. 2, Groups A, B, C, D |
| Altitud (Dimensi) | 5000 m (For restrictions see manufacturer's declaration) |
| Tork (Bekalan kuasa) | 0.22 Nm ... 0.25 Nm |
| UL, Kanada (Fungsi) | CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
| Pematuhan (Fungsi) | CE-compliant |
| Keputusan ujian (Fungsi) | 25g for 11 ms, three shocks in each direction |
| Jenis ujian (Fungsi) | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
| ATEX (Keadaan ambien) | II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
| MTTF (Keadaan ambien) | 3268 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| UL, Amerika Syarikat/Kanada (Fungsi) | Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 |
| Warna (Keadaan ambien) | gray |
| Julat frekuensi (Fungsi) | 0.15 MHz ... 80 MHz |
| Antara Muka 1 (Bekalan kuasa) | Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u |
| Antara Muka 2 (Bekalan kuasa) | Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u |
| Voltan (Antara muka bersiri) | ≤ 10 V |
| Kedalaman (Data Komersial Utama) | 86 mm |
| Ujian gas toksik (Fungsi) | ISA-S71.04-1985 G3 Harsh Group A |
| Lebar (Data Komersial Utama) | 23.8 mm |
| (Piawaian dan Peraturan) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Pelepasan sentuh (Fungsi) | ± 6 kV (Test Level 3) |
| Ketinggian (Data Komersial Utama) | 101.3 mm |
| Impedans (Antara muka bersiri) | ≤ 1 Ω |
| Ketepatan (Antara muka bersiri) | ± 5 % |
| UL, Amerika Syarikat (Keadaan ambien) | UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
| Pelepasan tidak langsung (Fungsi) | ± 6 kV |
| Penetapan pin (Bekalan kuasa) | 1:1 |
| Penamaan (Antara muka bersiri) | Shield current monitoring |
| Julat voltan bekalan (Umum) | 36 V DC ... 52 V DC 10 % (via PoE) |
| Berat bersih (Keadaan ambien) | 124.2 g |
| Panjang pelucutan (Bekalan kuasa) | 5 mm |
| UL, Kanada (Keadaan ambien) | CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
| Pematuhan (Keadaan ambien) | CE-compliant |
| Kaedah sambungan (Bekalan kuasa) | RJ45 CAT5e |
| Masa tindak balas (Antara muka bersiri) | 3 s |
| Piawaian/peraturan (Fungsi) | DIN EN 61643-21 |
| Tahap perlindungan (Dimensi) | IP20 (Manufacturer's declaration) |
| Pengelasan ujian IEC (Fungsi) | C2 |
| Panjang penghantaran (Bekalan kuasa) | 100 m (including patch cables) |
| Kuasa output maksimum (Bekalan kuasa) | 60 W |
| Voltan penebat yang dinilai (Fungsi) | 85 V DC |
| UL, Amerika Syarikat/Kanada (Keadaan ambien) | Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 |
| Diagnostik setempat (Antara muka bersiri) | Yellow LED |
| Penggunaan kuasa (Antara muka bersiri) | 270 mW (Shield current monitoring) |
| Berat setiap Keping (tidak termasuk pembungkusan) | 124.200 g |
| Bahan perumahan (Keadaan ambien) | Plastic |
| Arus keluaran maksimum (Bekalan kuasa) | 725 mA (PoE) |
| RoHS (Piawaian dan Peraturan) China | Environmentally Friendly Use Period = 50 |
| Ambang hidup (Antara muka bersiri) | ≥ 30 mA |
| Kapasiti bawaan arus (Bekalan kuasa) | ≤ 1.5 A (≤ 60 W (PoE+)) |
| Tahap pencemaran (Keadaan ambien) | 2 |
| Keserasian elektromagnet (Fungsi) | Conformance with EMC Directive 2014/30/EU |
| Kelajuan penghantaran bersiri (Bekalan kuasa) | 10/100/1000 Mbps |
| Lukisan dimensi (Data Komersial Utama) | |
| Pengasingan elektrik (Keadaan ambien) | FE // Ethernet |
| Kategori voltan lampau (Keadaan ambien) | II |
| Piawaian/peraturan (Keadaan ambien) | DIN EN 61643-21 |
| Suhu ambien (operasi) (Dimensi) | -40 °C ... 75 °C |
| Arus perisai berterusan (Antara muka bersiri) | ≤ 1.5 A |
| Kelembapan yang dibenarkan (operasi) (Dimensi) | 10 % ... 95 % (non-condensing) |
| Keratan rentas konduktor AWG maks. (Bekalan kuasa) | 16 |
| Keratan rentas konduktor AWG min. (Bekalan kuasa) | 28 |
| Keratan rentas konduktor pepejal maks. (Bekalan kuasa) | 1.5 mm² |
| Keratan rentas konduktor min. pepejal (Bekalan kuasa) | 0.14 mm² |
| Keserasian elektromagnet (Keadaan ambien) | Conformance with EMC Directive 2014/30/EU |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 85 °C |
| Keratan rentas konduktor fleksibel maksimum (Bekalan kuasa) | 1.5 mm² |
| Keratan rentas konduktor min fleksibel (Bekalan kuasa) | 0.14 mm² |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi