| Parameter | Nilai |
|---|---|
| T3 | |
| Nota | 2012 |
| Jenis | DIN rail module, two-section, divisible |
| Kedalaman | 74.5 mm (incl. DIN rail 7.5 mm) |
| Lebar | 17.7 mm |
| Ketinggian | ≤ 2000 m (amsl) |
| Jenis EN | T3 |
| Jenis SPD | 4CA |
| Jenis produk | Device protection |
| Benang skru | M3 |
| Jenis pemasangan | DIN rail: 35 mm |
| Kumpulan bahan | I |
| Keluarga produk | SEC Family |
| Nama sambungan | Remote fault indicator contact |
| Voltan nominal | 120 V DC |
| Bilangan port | One |
| Padang mendatar | 1 Div. |
| Bahan perumahan | PA 6.6-FR 20 % GF |
| Tahap pencemaran | 2 |
| Kaedah sambungan | Screw connection |
| Kekerapan nominal | 50/60 Hz |
| Arus operasi | 3 A AC |
| Voltan operasi | 250 V AC |
| Kejutan (pembedahan) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Tork pengetatan | 0.8 Nm |
| Cara perlindungan | L-N |
| Voltan nominal UN | 120 V AC (TN-S) |
| Fungsi pensuisan | N/C contact |
| Lukisan dimensi | |
| Arah tindakan | 1L-N & N-PE |
| Bahan penebat | PA 6.6-FR 20% GF |
| Bilangan jawatan | 2 |
| Gelombang gabungan UOC | 6 kV |
| Tahap perlindungan | IP20 |
| Frekuensi nominal fN | 50 Hz (60 Hz) |
| Kategori voltan lampau | III |
| IPE arus baki | ≤ 5 µA |
| Nilai CTI bahan | 600 |
| Arus beban dinilai IL | 26 A (30 °C) |
| Masa tindak balas tA(LN) | ≤ 25 ns |
| Getaran (operasi) | 5g (10 ... 150 Hz/20 cycles/axis/X, Y, Z) |
| Masa tindak balas tA(L-PE) | ≤ 100 ns |
| Masa tindak balas tA(N-PE) | ≤ 100 ns |
| Pengelasan ujian IEC | III |
| Tingkah laku TOV di UT(LN) | 240 V AC (5 s / withstand mode) |
| Piawaian/spesifikasi | EN 61643-11 |
| Tingkah laku TOV di UT(L-PE) | 240 V AC (5 s / withstand mode) |
| Tingkah laku TOV di UT(N-PE) | 1200 V AC (200 ms / safe failure mode) |
| Sistem pengagihan kuasa | Single phase |
| Keratan rentas konduktor AWG | 24 ... 12 |
| Voltan ujian rujukan UREF | 132 V AC |
| Arus nyahcas nominal Masuk | 3 kA |
| Penggunaan kuasa siap sedia PC | ≤ 150 mVA (at UREF) |
| Keratan rentas konduktor tegar | 0.2 mm² ... 4 mm² |
| Voltan berterusan maksimum UC | 150 V AC |
| Mesej kerosakan perlindungan lonjakan | Optical, remote indicator contact |
| Suhu ambien (operasi) | -40 °C ... 70 °C |
| Keratan rentas konduktor fleksibel | 0.2 mm² ... 2.5 mm² |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % |
| Tahap perlindungan voltan Naik (LN) | ≤ 0.85 kV |
| Tahap perlindungan voltan Naik (L-PE) | ≤ 0.95 kV |
| Tahap perlindungan voltan Naik (N-PE) | ≤ 0.95 kV |
| Penarafan arus litar pintas ISCCR | 1.5 kA AC |
| Fius sandaran maksimum dengan pendawaian cabang | not required |
| Voltan pengehad yang diukur MLV (LG) | 760 V |
| Voltan pengehad yang diukur MLV (LN) | 780 V |
| MLV (NG) voltan pengehad terukur | 760 V |
| Penarafan mudah terbakar mengikut UL 94 | V-0 |
| Voltan pengehad yang diukur MLV (L+) - G | 760 V |
| Voltan pengehad yang diukur MLV (L-) - G | 760 V |
| Arus nyahcas nominal In(8/20) µs | 3 kA |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 70 °C |
| Voltan operasi berterusan maksimum MCOV | 150 V AC |
| Voltan pengehad yang diukur MLV (L+) - (L-) | 780 V |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi