Waktu Perkhidmatan: Isnin hingga Jumaat 9:00-18:00
PLC-RPT-48DC/21HC - PLC-RPT- 48DC/21HC 2900294 PHOENIX CONTACT PLC-INTERFACE for high continuous currents, consisting of PLC-BPT..
Dalam Stok Produk Hangat

PLC-RPT-48DC/21HC

PLC-RPT- 48DC/21HC 2900294 PHOENIX CONTACT PLC-INTERFACE for high continuous currents, consisting of PLC-BPT..

$0.00USD
4965 dalam stok
Spesifikasi Utama
:Surge protection; Freewheeling diode
EMC:B
Warna:gray (RAL 7042)
Kedalaman:94 mm
Maklumat Pembekal
Produk: 0
Biasanya dihantar dalam 2-3 hari bekerja
Kualiti Dijamin
Penghantaran Pantas
Sokongan Teknikal

Spesifikasi Teknikal

ParameterNilai
Surge protection; Freewheeling diode
EMCB
Warnagray (RAL 7042)
Kedalaman94 mm
Lebar14 mm
Ketinggian80 mm
KelembapanA
KandangRequired protection according to the Rules shall be provided upon installation on board
GetaranB/C
PenebatSafe isolation, reinforced insulation
PermohonanHigh continuous currents
SijilCE-compliant
SuhuD
Jenis produkRelay Module
Nota perhimpunanin rows with zero spacing
Jenis pemasanganDIN rail mounting
PengenalpastianISA-S71.04. G3 Harsh Group
Mod operasi100% operating factor
Keluarga produkPLC-INTERFACE
Semakan artikel08
Bahan sentuhAgNi
Pemacu (kekutuban)polarized
Tahap pencemaran3
Panjang pelucutan10 mm
Kaedah sambunganPush-in connection
Kedudukan pemasanganany
Pemacu dan fungsimonostable
Litar pelindungReverse polarity protection; Polarity protection diode
Kapasiti pensuisan2 A (at 24 V, DC13)
Julat voltan input40.3 V DC ... 60 V DC (20 °C)
Voltan lonjakan yang dinilai6 kV
Kategori voltan lampauIII
Masa pelepasan biasa10 ms
Arahan Voltan RendahConformance with Low Voltage Directive
Piawaian/peraturanIEC 60947-5-1
Masa tindak balas biasa8 ms
Jenis pensuisan kenalan1 changeover contact
Arus masuk maksimum30 A (300 ms)
Arus pensuisan minimum10 mA (12 V)
Jenis kenalan suisSingle contact
Hayat perkhidmatan mekanikal3x 107cycles
Voltan input nominal UN48 V DC
Voltan pensuisan maksimum250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Voltan pensuisan minimum12 V (10 mA)
Paparan voltan operasiYellow LED
Keratan rentas konduktor AWG26 ... 14
Mengehadkan arus berterusan10 A
Arus input tipikal di UN20 mA
Tarikh pengurusan data terakhir01.07.2024
Tahap perlindungan (Relay)RT II (Relay)
Keratan rentas konduktor tegar0.14 mm² ... 2.5 mm²
Keserasian elektromagnetikConformance with EMC directive
Suhu ambien (operasi)-40 °C ... 60 °C
Keratan rentas konduktor fleksibel0.14 mm² ... 2.5 mm²
Tahap perlindungan (Tapak geganti)IP20 (Relay base)
Kadaran gangguan (beban ohm) maks.240 W (at 24 V DC)
Penarafan mudah terbakar mengikut UL 94V0 (Housing)
Suhu ambien (penyimpanan/pengangkutan)-40 °C ... 85 °C
Kadaran gangguan (beban ohm) maksimum yang dijambatani144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Pelesapan kuasa maksimum untuk keadaan nominal0.96 W
Voltan nominal (geganti elektromekanikal yang dipasang)24 V DC

Penerangan Produk

PLC-INTERFACE for high constant currents, consisting of PLC-BPT.../21 HC base terminal block with push-in connection and plug-in miniature relay, for mounting on NS 35/7.5 rail, constant current limit
Ciri-ciri Utama
  • Kualiti gred industri
  • Patuh RoHS
  • Sijil CE
  • Jaminan 1 tahun

Dokumen Produk

Lembaran Data

Spesifikasi teknikal dan data prestasi

Manual Pengguna

Panduan pemasangan dan operasi

Top