| Parameter | Nilai |
|---|---|
| (Umum) | IEC 62103 |
| Kedalaman (Nota) | 86 mm |
| Lebar (Nota) | 6.2 mm |
| (Data input) | Surge protection |
| Ketinggian (Nota) | 80 mm |
| UNSPSC 11 (ETIM) | 39121542 |
| ETIM 4.0 (eCl@ss) | EC000196 |
| ETIM 5.0 (eCl@ss) | EC001504 |
| UNSPSC 13.2 (ETIM) | 39121542 |
| UNSPSC 6.01 (ETIM) | 30211916 |
| UNSPSC 12.01 (ETIM) | 39121542 |
| Kipas keluar (Data input) | 1 |
| UNSPSC 7.0901 (ETIM) | 39121542 |
| (Keadaan ambien) | Surge protection |
| Jawatan (Umum) | Air clearances and creepage distances between the power circuits |
| Sekatan penggunaan | EMC: class A product, see manufacturer's declaration in the download area |
| Jawatan (Data input) | Output data |
| Litar output (Data input) | 3-conductor, ground-referenced |
| Nama sambungan (Data output) | Input side |
| Tahap pencemaran (Umum) | 2 |
| Kategori voltan lampau (Umum) | III |
| Panjang pelucutan (Data output) | 8 mm |
| (Data sambungan, bahagian output) | IEC 62103 |
| Kaedah sambungan (Data output) | Push-in connection |
| Piawaian/peraturan (Umum) | IEC 60664 |
| Jenis perlindungan (Data input) | Reverse polarity protection |
| Tahap perlindungan (Dimensi) | IP20 |
| Voltan penebat yang dinilai (Umum) | 250 V DC |
| Voltan nominal output (Data input) | 5 V DC -10 % ... +20 % |
| Perlindungan voltan lonjakan (Data input) | > 8 V |
| eCl@ss 4.0 (Piawaian dan Peraturan) | 27371001 |
| eCl@ss 4.1 (Piawaian dan Peraturan) | 27371001 |
| eCl@ss 5.0 (Piawaian dan Peraturan) | 27371001 |
| eCl@ss 5.1 (Piawaian dan Peraturan) | 27371001 |
| eCl@ss 6.0 (Piawaian dan Peraturan) | 27371001 |
| eCl@ss 7.0 (Piawaian dan Peraturan) | 27371001 |
| eCl@ss 8.0 (Piawaian dan Peraturan) | 27371604 |
| eCl@ss 9.0 (Piawaian dan Peraturan) | 27371604 |
| Jenis perlindungan (Keadaan ambien) | Reverse polarity protection |
| Mengehadkan arus berterusan (Data input) | A TTL load (Fan out = 1)/50 mA for switching mode |
| Voltan/penebat lonjakan yang dinilai (Umum) | 4 kV / basic insulation |
| Keratan rentas konduktor AWG (Data output) | 26 ... 14 |
| Litar/komponen pelindung (Data input) | Parallel polarity protection diode |
| Sambungan dalam akaun dengan standard (Umum) | CUL |
| Penetapan (Data sambungan, bahagian output) | Air clearances and creepage distances between the power circuits |
| Masa tindak balas biasa (Keadaan ambien) | 35 µs |
| Masa pemadaman biasa (Keadaan ambien) | 35 µs |
| Pepejal keratan rentas konduktor (Data output) | 0.14 mm² ... 2.5 mm² |
| Frekuensi penghantaran (Keadaan ambien) | 1 kHz |
| Suhu ambien (operasi) (Dimensi) | -25 °C ... 60 °C |
| Nama sambungan (Data sambungan, bahagian input) | Output side |
| Voltan input nominal UN (Keadaan ambien) | 24 V DC |
| Mod operasi (Data sambungan, bahagian output) | 100% operating factor |
| Perlindungan voltan lonjakan (Keadaan ambien) | > 33 V |
| Keratan rentas konduktor fleksibel (Data output) | 0.14 mm² ... 2.5 mm² |
| Paparan voltan operasi (Keadaan ambien) | Yellow LED |
| Panjang pelucutan (Data sambungan, bahagian input) | 8 mm |
| Kaedah sambungan (Data sambungan, bahagian input) | Push-in connection |
| Penarafan mudah terbakar mengikut UL 94 (Umum) | V0 |
| Kedudukan pemasangan (Data sambungan, bahagian output) | any |
| Arus input tipikal di UN (Keadaan ambien) | 3.4 mA |
| Litar/komponen pelindung (Keadaan ambien) | Parallel polarity protection diode |
| Tahap pencemaran (Data sambungan, bahagian output) | 2 |
| Kategori voltan lampau (Data sambungan, bahagian output) | III |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 85 °C |
| Arahan pemasangan (Data sambungan, bahagian output) | In rows with zero spacing |
| Piawaian/peraturan (Data sambungan, bahagian output) | IEC 60664 |
| Voltan penebat yang dinilai (Data sambungan, bahagian output) | 250 V DC |
| Input/output voltan ujian (Data sambungan, bahagian output) | 2.5 kVrms(50 Hz, 1 min.) |
| Keratan rentas konduktor AWG (Data sambungan, sisi input) | 26 ... 14 |
| Keratan rentas konduktor pepejal (Data sambungan, sisi input) | 0.14 mm² ... 2.5 mm² |
| Julat voltan input merujuk kepada UN (keadaan ambien) | 0.8 ... 1.2 |
| Voltan/penebat lonjakan yang dinilai (Data sambungan, bahagian output) | 4 kV / basic insulation |
| Susut voltan pada arus berterusan pengehad maksimum (Data input) | < 80 mV |
| Keratan rentas konduktor fleksibel (Data sambungan, sisi input) | 0.14 mm² ... 2.5 mm² |
| Penarafan mudah terbakar mengikut UL 94 (Data sambungan, bahagian output) | V0 |
| Isyarat ambang penukaran "0" merujuk kepada UN (Keadaan ambien) | < 0.4 |
| Isyarat ambang penukaran "1" merujuk kepada UN (Keadaan ambien) | > 0.8 |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi