| Parameter | Nilai |
|---|---|
| GTIN | 4046356073462 |
| Kunci Pesanan | 2882394 |
| Halaman katalog | Page 74 (C-4-2017) |
| Unit pembungkusan | 1 pc |
| Negara asal | DE (Germany) |
| Jenis EN (Umum) | T3 |
| Nombor tarif tersuai | 85363010 |
| Jenis (Keadaan ambien) | Attachment plug |
| Warna (Keadaan ambien) | pure white RAL 9010 |
| Kedalaman (Data Komersial Utama) | 78 mm |
| Lebar (Data Komersial Utama) | 63 mm |
| Ketinggian (Data Komersial Utama) | 103 mm |
| Voltan nominal PBB (Umum) | 230 V AC |
| Masa tindak balas (LN) (Umum) | ≤ 25 ns |
| Gelombang gabungan UOC (Umum) | 4 kV |
| Frekuensi nominal fN (Umum) | 50 Hz (60 Hz) |
| Arus baki IPE (Umum) | ≤ 5 µA |
| Masa tindak balas (L-PE) (Umum) | ≤ 100 ns |
| Masa tindak balas (N-PE) (Umum) | ≤ 100 ns |
| Arus beban dinilai IL (Umum) | 16 A (30 °C) |
| Jenis pemasangan (Keadaan ambien) | Plugging into the mains socket |
| Fius sandaran maksimum yang diperlukan (Umum) | 16 A (gG / B / C) |
| Berat setiap Keping (tidak termasuk pembungkusan) | 195.300 g |
| Bahan perumahan (Keadaan ambien) | PA 6 |
| Penggunaan kuasa siap sedia PC (Umum) | ≤ 1 VA |
| Voltan penangkap undian UC(LN) (Umum) | 275 V AC |
| Arah tindakan (Keadaan ambien) | L/N-PE & Signal Line-Earth Ground |
| Mesej kerosakan perlindungan lonjakan (Umum) | optical |
| Voltan penangkap undian UC(L-PE) (Umum) | 360 V AC |
| Voltan penangkap undian UC(N-PE) (Umum) | 360 V AC |
| Kaedah sambungan (Bekalan kuasa, umum) | Via protective contact plug |
| Tahap perlindungan voltan Naik (LN) (Umum) | ≤ 1.2 kV |
| Tahap perlindungan voltan Naik (L-PE) (Umum) | ≤ 1.5 kV |
| Tahap perlindungan voltan Naik (N-PE) (Umum) | ≤ 1.5 kV |
| Suhu ambien (operasi) (Dimensi) | -25 °C ... 75 °C |
| (Sambungan (litar pelindung, bekalan kuasa)) | D1 - 500 A |
| Untuk kegunaan khusus negara dalam (Keadaan ambien) | D |
| Arus nyahcas nominal In(8/20) µs (Umum) | 3 kA (> 5x) |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -25 °C ... 75 °C |
| Kaedah sambungan (Litar pelindung, bekalan kuasa) | Grounding plug/socket |
| Kaedah sambungan IN (Litar pelindung, bekalan kuasa) | Grounding plug |
| Kaedah sambungan OUT (Litar pelindung, bekalan kuasa) | Grounding socket |
| Penarafan mudah terbakar mengikut UL 94 (Keadaan ambien) | V-0 |
| (Sambungan, ikatan saksama keupayaan, teknologi maklumat) | D1 |
| Arus yang dinilai (Sambungan (litar pelindung, bekalan kuasa)) | 150 mA (25 °C) |
| Kaedah sambungan (Litar pelindung, teknologi maklumat) | RJ12-/TAE 6 |
| Kaedah sambungan IN (Litar pelindung, teknologi maklumat) | RJ12 female connector |
| Kaedah sambungan OUT (Litar pelindung, teknologi maklumat) | TAE 6 socket |
| Kapasiti (talian-talian) (Sambungan (litar pelindung, bekalan kuasa)) | typ. 1 nF |
| Arus baki IPE (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 2 µA |
| Kapasiti (line-earth) (Sambungan (litar pelindung, bekalan kuasa)) | typ. 5 pF |
| Voltan penangkap undian UC (Sambungan (litar pelindung, bekalan kuasa)) | 200 V DC |
| Rintangan penebat Riso (Sambungan (litar pelindung, bekalan kuasa)) | ≥ 1 MΩ |
| Masa tindak balas tA (talian-talian) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 25 ns |
| Masa penetapan semula denyut (talian-talian) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 15 ms |
| Masa tindak balas tA (line-earth) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 100 ns |
| Ketahanan impuls (talian-talian) (Sambungan (litar pelindung, bekalan kuasa)) | C2 - 2 kV / 1 kA |
| Ketahanan impuls (line-earth) (Sambungan (litar pelindung, bekalan kuasa)) | C2 - 4 kV/2 kA |
| Voltan baki pada In (line-line) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 500 V |
| Voltan baki pada In(line-earth) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 30 V |
| Pengelasan ujian IEC (Sambungan, ikatan sama upaya, teknologi maklumat) | C1 |
| Arus berkesan operasi ICat UC (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 150 µA |
| Arus nyahcas maksimum Imax(8/20) µs (Sambungan (litar pelindung, bekalan kuasa)) | 2.5 kA |
| Tahap perlindungan voltan Naik (talian-talian) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 460 V (C2 - 1 kA) |
| Tahap perlindungan voltan Naik (line-earth) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 900 V (C2 - 2 kA) |
| Kapasiti bawaan arus ulang-alik (talian-talian) (Sambungan (litar pelindung, bekalan kuasa)) | 250 mA - 1 s |
| Had voltan output pada 1 kV/µs (wayar-wayar) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 360 V |
| Kapasiti daya bawa arus ulang-alik (line-earth) (Sambungan (litar pelindung, bekalan kuasa)) | 10 A - 1 s |
| Arus nyahcas nominal In(8/20) µs (talian-talian) (Sambungan (litar pelindung, bekalan kuasa)) | 1 kA |
| Frekuensi potong fg (3 dB), sim. dalam sistem 100 Ohm (Sambungan (litar pelindung, bekalan kuasa)) | typ. 4 MHz |
| Frekuensi potong fg (3 dB), sim. dalam sistem 150 Ohm (Sambungan (litar pelindung, bekalan kuasa)) | typ. 3 MHz |
| Frekuensi potong fg (3 dB), sim. dalam sistem 600 Ohm (Sambungan (litar pelindung, bekalan kuasa)) | typ. 700 kHz |
| Arus nyahcas nominal In(8/20) µs (line-earth) (Sambungan (litar pelindung, bekalan kuasa)) | 2.5 kA |
| Voltan baki dengan Ian (10/1000) µs (talian-talian) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 35 V |
| Voltan baki dengan Ian (10/1000) µs (line-earth) (Sambungan (litar pelindung, bekalan kuasa)) | ≤ 35 V |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi