| Parameter | Nilai |
|---|---|
| GTIN | 4046356142472 |
| Kunci Pesanan | 2810395 |
| (Data EMC) | Class I, Div. 2, Groups A, B, C, D T4 |
| Halaman katalog | Page 106 (C-7-2015) |
| Kedalaman (Nota) | 102.5 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 6.2 mm |
| (Data input) | 20 mA ... 4 mA |
| Ketinggian (Nota) | 93.1 mm |
| ATEX (data EMC) | II 3 G Ex nA IIC T4 Gc X |
| Negara asal | DE (Germany) |
| (Data sambungan) | Class I, Div. 2, Groups A, B, C, D T4 |
| Riak (Data input) | < 20 mVPP(at 500 Ω) |
| Nombor tarif tersuai | 85437090 |
| Jawatan (Umum) | Conducted interferences |
| ATEX (Data Sambungan) | II 3 G Ex nA IIC T4 Gc X |
| Pematuhan (data EMC) | CE-compliant |
| Penamaan (data EMC) | Conducted interferences |
| Warna (Data sambungan) | green |
| Penetapan (Data output) | Loop-powered |
| Pelepasan hingar (data EMC) | EN 61000-6-4 |
| UL, Amerika Syarikat/Kanada (data EMC) | UL 508 Recognized |
| (Piawaian dan Peraturan) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Pematuhan (Data Sambungan) | CE-compliant |
| Ketinggian maksimum (Dimensi) | ≤ 2000 m |
| Bilangan output (Data input) | 1 |
| Pengasingan elektrik (data EMC) | Basic insulation according to EN 61010 |
| Penggunaan kuasa (Data output) | < 150 mW (without signal current) |
| Piawaian/peraturan (Umum) | EN 61000-4-6 |
| Panjang pelucutan (Bekalan kuasa) | 8 mm |
| Kaedah sambungan (Bekalan kuasa) | Spring-cage connection |
| Arus output maksimum (Data input) | 23 mA (output limit) |
| Pelepasan hingar (Data sambungan) | EN 61000-6-4 |
| Kekebalan hingar (Data sambungan) | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Piawaian/peraturan (data EMC) | EN 61000-4-6 |
| UL, Amerika Syarikat/Kanada (Data sambungan) | UL 508 Recognized |
| Ralat lineariti (Data sambungan) | < 0.05 % (for full measuring range) |
| Isyarat output semasa (Data input) | 4 mA ... 20 mA |
| Bahan perumahan (Data sambungan) | PBT |
| Julat voltan bekalan (Data output) | 12 V DC ... 30 V DC |
| Kedudukan pemasangan (Data sambungan) | any |
| Berat setiap Keping (tidak termasuk pembungkusan) | 100.700 g |
| Tahap pencemaran (Data sambungan) | 2 |
| RoHS (Piawaian dan Peraturan) China | Environmentally Friendly Use Period = 50 |
| Boleh dikonfigurasikan/diprogramkan (Data input) | Yes, unconfigured |
| Pengasingan elektrik (Data sambungan) | Basic insulation according to EN 61010 |
| Penggunaan arus maksimum (Data output) | < 4.5 mA (without signal current) |
| Kategori voltan lampau (Data sambungan) | II |
| Keserasian elektromagnet (data EMC) | Conformance with EMC directive |
| Arus input sensor (Keadaan ambien) | 1 mA (constant) |
| Teknologi sambungan (Keadaan ambien) | 2, 3, 4-wire |
| Voltan penebat yang dinilai (Data sambungan) | 30 V AC |
| Sambungan dalam akaun dengan standard (data EMC) | CUL |
| Suhu ambien (operasi) (Dimensi) | -20 °C ... 65 °C |
| Arus beban beban/output output (Data input) | (Usupply- 12 V) / 22 mA |
| Sekatan penggunaan (Data Komersial Utama) | 1 |
| Boleh dikonfigurasikan/diprogramkan (Keadaan ambien) | Yes, unconfigured |
| Keratan rentas konduktor AWG maks. (Bekalan kuasa) | 12 |
| Keratan rentas konduktor AWG min. (Bekalan kuasa) | 24 |
| Keserasian elektromagnet (Data sambungan) | Conformance with EMC directive |
| Keratan rentas konduktor pepejal maks. (Bekalan kuasa) | 2.5 mm² |
| Keratan rentas konduktor min. pepejal (Bekalan kuasa) | 0.2 mm² |
| Pekali suhu maksimum (Data sambungan) | < 0.02 %/K |
| Voltan ujian, input/output/bekalan (Data sambungan) | 1.5 kV (50 Hz, 1 min.) |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 85 °C |
| Keratan rentas konduktor fleksibel maksimum (Bekalan kuasa) | 2.5 mm² |
| Keratan rentas konduktor min fleksibel (Bekalan kuasa) | 0.2 mm² |
| Jenis sensor (RTD) yang boleh digunakan (Keadaan ambien) | Pt 100 (IEC 60751/EN 60751) |
| Ralat penghantaran dalam julat pengukuran yang ditetapkan (Data sambungan) | ((90 K / set measuring range [K]) + 0.05)% |
| Ralat penghantaran dalam julat pengukuran penuh (Data Sambungan) | ≤ 0,25 % |
| Sisihan tipikal daripada nilai akhir julat pengukuran (Umum) | 5 % |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R22 (data EMC) | HL 1 - HL 2 |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R23 (data EMC) | HL 1 - HL 2 |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R24 (data EMC) | HL 1 - HL 2 |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R22 (Data sambungan) | HL 1 - HL 2 |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R23 (Data sambungan) | HL 1 - HL 2 |
| Perlindungan kebakaran untuk kenderaan rel (DIN EN 45545-2) R24 (Data sambungan) | HL 1 - HL 2 |
Spesifikasi teknikal dan data prestasi