| Parameter | Nilai |
|---|---|
| GTIN | 4046356629119 |
| Kunci Pesanan | 2811860 |
| (Umum) | Class I, Zone 2, Group IIC T6 |
| Halaman katalog | Page 128 (C-5-2017) |
| Kedalaman (Nota) | 114.5 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 17.5 mm |
| (Data input) | 1 A (30 V DC) |
| Ketinggian (Nota) | 99 mm |
| ATEX (Umum) | II 3 G Ex nA nC ic IIC T4 Gc X |
| IECEx (Umum) | Ex nA nC ic IIC T4 Gc X |
| Negara asal | DE (Germany) |
| (Data sambungan) | Class I, Zone 2, Group IIC T6 |
| Nombor tarif tersuai | 85437090 |
| DNV GL-EMC (Umum) | A |
| Pematuhan (Umum) | CE-compliant |
| SIL (Data sambungan) | 2 |
| ATEX (Data Sambungan) | II 3 G Ex nA nC ic IIC T4 Gc X |
| Warna (Data sambungan) | gray |
| IECEx (Data Sambungan) | Ex nA nC ic IIC T4 Gc X |
| Nama output (Data input) | Relay output |
| UL, Amerika Syarikat/Kanada (Umum) | UL 508 Listed |
| Jenis kenalan (Data input) | 1 PDT |
| DNV GL-Kelembapan (Umum) | B |
| Kandang DNV GL (Umum) | Required protection according to the Rules shall be provided upon installation on board |
| DNV GL-Getaran (Umum) | A |
| Kekebalan hingar (Dimensi) | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| (Piawaian dan Peraturan) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Suhu DNV GL (Umum) | B |
| Pematuhan (Data Sambungan) | CE-compliant |
| Bahan sentuh (Data input) | AgSnO2, hard gold-plated |
| Penetapan (Data sambungan) | Input/switching output |
| Ketinggian maksimum (Dimensi) | ≤ 2000 m |
| Pengasingan elektrik (Umum) | 4-way, between input/output/power supply/switching output |
| Penggunaan kuasa (Data output) | < 1.5 W |
| Panjang pelucutan (Bekalan kuasa) | 8 mm |
| Kaedah sambungan (Bekalan kuasa) | Push-in connection |
| UL, Amerika Syarikat/Kanada (Data sambungan) | UL 508 Listed |
| Isyarat output semasa (Data input) | 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL) |
| Bahan perumahan (Data sambungan) | PA 6.6-FR |
| Julat voltan bekalan (Data output) | 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz) |
| Arus masuk maksimum (Data input) | 0.5 A (30 V AC) |
| Berat setiap Keping (tidak termasuk pembungkusan) | 150.000 g |
| Tahap pencemaran (Data sambungan) | 2 |
| RoHS (Piawaian dan Peraturan) China | Environmentally Friendly Use Period = 50 |
| Boleh dikonfigurasikan/diprogramkan (Data input) | no |
| Pengasingan elektrik (Data sambungan) | 375 V (Peak value in accordance with EN 60079-11) |
| Voltan pensuisan maksimum (Data input) | 30 V AC (30 V DC) |
| Kategori voltan lampau (Data sambungan) | II |
| REACh SVHC (Piawaian dan Peraturan) | Lead 7439-92-1 |
| Keserasian elektromagnet (Umum) | Conformance with EMC directive |
| Julat isyarat input (Keadaan ambien) | -1000 mV ... 1000 mV |
| Isyarat output arus maksimum (Data input) | 22 mA |
| Isyarat output voltan maksimum (Data input) | ± 11 V |
| Suhu ambien (operasi) (Dimensi) | -20 °C ... 65 °C |
| Arus beban beban/output output (Data input) | ≤ 600 Ω (at 20 mA) |
| Output voltan beban beban/output (Data input) | ≥ 10 kΩ |
| Kelembapan yang dibenarkan (operasi) (Dimensi) | typ. 5 % ... 95 % (non-condensing) |
| Sekatan penggunaan (Data Komersial Utama) | 1 |
| Keratan rentas konduktor AWG maks. (Bekalan kuasa) | 16 |
| Keratan rentas konduktor AWG min. (Bekalan kuasa) | 24 |
| Keserasian elektromagnet (Data sambungan) | Conformance with EMC directive |
| Penarafan mudah terbakar mengikut UL 94 (Umum) | V0 |
| Julat pengukuran suhu (Keadaan ambien) | -250 °C ... 2500 °C (Range depending on the sensor type) |
| Keratan rentas konduktor pepejal maks. (Bekalan kuasa) | 1.5 mm² |
| Keratan rentas konduktor min. pepejal (Bekalan kuasa) | 0.2 mm² |
| Pekali suhu maksimum (Data sambungan) | 0.01 %/K |
| Julat rintangan potensiometer (Keadaan ambien) | 0 Ω ... 50 kΩ |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 85 °C |
| Tingkah laku sekiranya berlaku ralat sensor (Data input) | according to NE 43 or freely configurable |
| Keratan rentas konduktor fleksibel maksimum (Bekalan kuasa) | 1.5 mm² |
| Keratan rentas konduktor min fleksibel (Bekalan kuasa) | 0.2 mm² |
| Jenis sensor yang boleh digunakan (TC) (Keadaan ambien) | B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG |
| Penarafan mudah terbakar mengikut UL 94 (Data sambungan) | V0 |
| Jenis sensor (RTD) yang boleh digunakan (Keadaan ambien) | Pt, Ni, Cu sensors: 2, 3, 4-wire |
Spesifikasi teknikal dan data prestasi