| Parameter | Nilai |
|---|---|
| GTIN | 4046356449540 |
| Kunci Pesanan | 2865971 |
| (Data EMC) | Class I, Zone 2, Group IIC T4 |
| Halaman katalog | Page 126 (C-5-2017) |
| Kedalaman (Nota) | 114.5 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 12.5 mm |
| (Data input) | < 730 Ω (22.5 mA) |
| Ketinggian (Nota) | 112.5 mm |
| ATEX (data EMC) | II 3 G Ex nA IIC T4 Gc X |
| Negara asal | DE (Germany) |
| (Data sambungan) | Class I, Zone 2, Group IIC T4 |
| Nombor tarif tersuai | 85437090 |
| (Keadaan ambien) | 4 mA ... 20 mA |
| DNV GL-EMC (data EMC) | B |
| SIL (Data sambungan) | 2 |
| ATEX (Data Sambungan) | II 3 G Ex nA IIC T4 Gc X |
| Pematuhan (data EMC) | CE-compliant, additionally EN 61326-1 |
| Penamaan (data EMC) | Electromagnetic RF field |
| Warna (Data sambungan) | gray |
| Fungsi HART (Umum) | Yes |
| Pelepasan hingar (data EMC) | EN 61000-6-4 |
| UL, Amerika Syarikat/Kanada (data EMC) | UL 508 Listed |
| Kelembapan DNV GL (data EMC) | B |
| Riak output (Data input) | < 20 mVrms |
| Output isyarat (Data input) | Current output |
| Lampiran DNV GL (data EMC) | Required protection according to the Rules shall be provided upon installation on board |
| Getaran DNV GL (data EMC) | A |
| Kekebalan hingar (Dimensi) | EN 61000-6-2 |
| Benang skru (Bekalan kuasa) | M3 |
| (Piawaian dan Peraturan) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Pematuhan (Data Sambungan) | CE-compliant, additionally EN 61326-1 |
| Suhu DNV GL (data EMC) | B |
| Penetapan (Data sambungan) | Input/output/power supply |
| Ketinggian maksimum (Dimensi) | ≤ 2000 m |
| Protokol yang disokong (Umum) | HART |
| (Komunikasi data (pintasan)) | 12.2 x 10-4(10 years) |
| Pelesapan kuasa (Data output) | < 1.1 W (24 V DC / 20 mA) |
| Panjang pelucutan (Bekalan kuasa) | 7 mm |
| Kaedah sambungan (Bekalan kuasa) | Screw connection |
| Piawaian/peraturan (data EMC) | EN 61000-4-3 |
| Paparan status (Data sambungan) | Green LED (supply voltage) |
| UL, Amerika Syarikat/Kanada (Data sambungan) | UL 508 Listed |
| Bilangan saluran (Data sambungan) | 1 |
| Isyarat output semasa (Data input) | 0 mA ... 20 mA |
| Bahan perumahan (Data sambungan) | PA 6.6-FR |
| Julat voltan bekalan (Data output) | 19.2 V DC ... 30 V DC (24 V DC -20%...+25%) |
| Tingkah Laku Penghantaran (Data input) | 1:1 to input signal |
| λDD (Komunikasi data (pintasan)) | 0 |
| λDU (Komunikasi data (pintasan)) | 2.79 x 10-8(27.9 FIT) |
| λSD (Komunikasi data (pintasan)) | 0 |
| λSU (Komunikasi data (pintasan)) | 4.965 x 10-7(496.5 FIT) |
| Impedans input (Keadaan ambien) | > 100 kΩ (If there is a line fault) |
| Voltan bekalan nominal (Data output) | 24 V DC |
| Tork pengetatan maksimum (Bekalan kuasa) | 0.6 Nm |
| Berat setiap Keping (tidak termasuk pembungkusan) | 140.900 g |
| Tahap pencemaran (Data sambungan) | 2 |
| Tork pengetatan, min (Bekalan kuasa) | 0.5 Nm |
| RoHS (Piawaian dan Peraturan) China | Environmentally Friendly Use Period = 50 |
| Pengasingan elektrik (Data sambungan) | 1.5 kV (50 Hz, 1 min., test voltage) |
| Penggunaan arus maksimum (Data output) | < 46 mA (24 V DC / 20 mA) |
| Kategori voltan lampau (Data sambungan) | II |
| Pelepasan gangguan (Data sambungan) | EN 61000-6-4 |
| Penetapan (Data ciri keselamatan) | Electromagnetic RF field |
| Keserasian elektromagnet (data EMC) | Conformance with EMC directive |
| Respons langkah (10-90%) (Data sambungan) | < 140 µs (for 4 mA ... 20 mA step) |
| Isyarat input semasa (Keadaan ambien) | 0 mA ... 20 mA |
| Suhu ambien (operasi) (Dimensi) | -20 °C ... 60 °C (Any mounting position) |
| Jenis peralatan (Komunikasi data (pintasan)) | Type A |
| Arus beban beban/output output (Data input) | < 800 Ω (20 mA) |
| Ralat penghantaran maksimum (Data sambungan) | < 0.1 % (of final value) |
| Had voltan input (Keadaan ambien) | 5.4 V (at 20 mA) |
| Kelembapan yang dibenarkan (operasi) (Dimensi) | 10 % ... 95 % (non-condensing) |
| Ralat penghantaran, tipikal (Data sambungan) | < 0.05 % (of final value) |
| Sekatan penggunaan (Data Komersial Utama) | 1 |
| Keratan rentas konduktor AWG maks. (Bekalan kuasa) | 14 |
| Keratan rentas konduktor AWG min. (Bekalan kuasa) | 24 |
| Keserasian elektromagnet (Data sambungan) | Conformance with EMC directive |
| Keratan rentas konduktor pepejal maks. (Bekalan kuasa) | 2.5 mm² |
| Keratan rentas konduktor min. pepejal (Bekalan kuasa) | 0.2 mm² |
| Penarafan mudah terbakar mengikut UL 94 (data EMC) | V0 |
| Pekali suhu maksimum (Data sambungan) | < 0.01 %/K |
| Piawaian/peraturan (Data ciri keselamatan) | EN 61000-4-3 |
| Keperluan integriti (Komunikasi data (pintasan)) | IEC 61508 - High demand |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 85 °C |
| Keratan rentas konduktor fleksibel maksimum (Bekalan kuasa) | 2.5 mm² |
| Keratan rentas konduktor min fleksibel (Bekalan kuasa) | 0.2 mm² |
| Liputan diagnostik (DC) (Komunikasi data (pintasan)) | DCS=0 %, DCD=0 % |
| Penarafan mudah terbakar mengikut UL 94 (Data sambungan) | V0 |
| Pecahan Kegagalan Selamat (SFF) (Komunikasi data (pintasan)) | 94.68 % |
| Tahap Integriti Keselamatan (SIL) (Komunikasi data (pintasan)) | 2 |
| Kebarangkalian kegagalan berbahaya sejam (PFHD) (Komunikasi data (pintasan)) | 2,79 x 10-8 |
| Kebarangkalian kegagalan berbahaya atas permintaan (PFDAVG) (Komunikasi data (pintasan)) | 1.22 x 10-4(1 year) |
Spesifikasi teknikal dan data prestasi