| Parameter | Nilai |
|---|---|
| GTIN | 4046356463676 |
| Kunci Pesanan | 2924236 |
| Halaman katalog | Page 141 (C-5-2017) |
| Kedalaman (Nota) | 114.5 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 12.5 mm |
| (Data input) | 0 mA (Cable short-circuit in the input) |
| Ketinggian (Nota) | 99 mm |
| (Data keselamatan) | IIB |
| Negara asal | DE (Germany) |
| (Data sambungan) | Ex nA [ia Ga] IIC T4 Gc |
| ATEX (Data keselamatan) | II (1) G [Ex ia Ga] IIC |
| Kumpulan (Data keselamatan) | IIC |
| IECEx (Data keselamatan) | [Ex ia Ga] IIC |
| Nombor tarif tersuai | 85437090 |
| (Keadaan ambien) | 4 mA ... 20 mA |
| SIL (Data sambungan) | 2 |
| ATEX (Data Sambungan) | II (1) G [Ex ia Ga] IIC |
| Warna (Data sambungan) | gray |
| Fungsi HART (Umum) | Yes |
| IECEx (Data Sambungan) | [Ex ia Ga] IIC |
| DNV GL-EMC (Data keselamatan) | A |
| Pematuhan (Data keselamatan) | CE-compliant, additionally EN 61326 |
| Riak output (Data input) | < 20 mVrms |
| Output isyarat (Data input) | Signal conditioner operation |
| Kekebalan hingar (Dimensi) | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| (Piawaian dan Peraturan) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Pelepasan hingar (Data keselamatan) | EN 61000-6-4 |
| UL, Amerika Syarikat/Kanada (Data keselamatan) | Class I Div 2; IS for Class I, II, III Div 1 |
| Pematuhan (Data Sambungan) | CE-compliant, additionally EN 61326 |
| DNV GL-Kelembapan (Data Keselamatan) | B |
| Penetapan (Data sambungan) | Output 1/output 2 |
| Ketinggian maksimum (Dimensi) | ≤ 2000 m |
| Protokol yang disokong (Umum) | HART |
| DNV GL-Kandang (Data keselamatan) | Required protection according to the Rules shall be provided upon installation on board |
| DNV GL-Getaran (Data keselamatan) | A |
| Pelesapan kuasa (Data output) | < 1.1 W (24 V DC/ 20 mA) |
| Panjang pelucutan (Bekalan kuasa) | 8 mm |
| Kaedah sambungan (Bekalan kuasa) | Push-in connection |
| Suhu DNV GL (Data Keselamatan) | B |
| Paparan status (Data sambungan) | Green LED (PWR supply voltage) |
| UL, Amerika Syarikat/Kanada (Data sambungan) | Class I Div 2; IS for Class I, II, III Div 1 |
| Bilangan saluran (Data sambungan) | 1 |
| Input isyarat (Keadaan ambien) | Signal conditioner operation |
| Penurunan voltan (Keadaan ambien) | approx. 3.9 V (in input isolating amplifier operation) |
| Isyarat output semasa (Data input) | 0 mA ... 20 mA (active) |
| Bahan perumahan (Data sambungan) | PA 6.6-FR |
| Julat voltan bekalan (Data output) | 19.2 V DC ... 30 V DC (24 V DC -20%...+25%) |
| Kumpulan (Komunikasi data (pintasan)) | IIB |
| Voltan bekalan nominal (Data output) | 24 V DC |
| Berat setiap Keping (tidak termasuk pembungkusan) | 165.000 g |
| RoHS (Piawaian dan Peraturan) China | Environmentally Friendly Use Period = 50 |
| Pengasingan elektrik (Data sambungan) | 1.5 kV AC (50 Hz, 1 min., test voltage) |
| Penggunaan arus maksimum (Data output) | < 46 mA (24 V DC / 20 mA) |
| REACh SVHC (Piawaian dan Peraturan) | Lead 7439-92-1 |
| Pelepasan gangguan (Data sambungan) | EN 61000-6-4 |
| Operasi (Komunikasi data (pintasan)) | Signal conditioner operation |
| Respons langkah (10-90%) (Data sambungan) | 1.3 ms (for jump 4 mA ... 20 mA, typical) |
| Isyarat input semasa (Keadaan ambien) | 0 A ... 20 mA |
| Julat voltan bekalan nominal (Data output) | 19.2 V DC ... 30 V DC (24 V DC -20%...+25%) |
| Keserasian elektromagnet (Data keselamatan) | Conformance with EMC directive |
| Suhu ambien (operasi) (Dimensi) | -20 °C ... 60 °C (Any mounting position) |
| Arus beban beban/output output (Data input) | < 450 Ω (20 mA) |
| Ralat penghantaran maksimum (Data sambungan) | < 0.1 % (of final value) |
| Kelembapan yang dibenarkan (operasi) (Dimensi) | 10 % ... 95 % (non-condensing) |
| Ralat penghantaran, tipikal (Data sambungan) | < 0.05 % (of final value) |
| Sekatan penggunaan (Data Komersial Utama) | 1 |
| Arus input Ii (Komunikasi data (pintasan)) | ≤ 150 mA |
| Voltan input Ui (Komunikasi data (pintasan)) | ≤ 30 V |
| Keratan rentas konduktor AWG maks. (Bekalan kuasa) | 16 |
| Keratan rentas konduktor AWG min. (Bekalan kuasa) | 24 |
| Keserasian elektromagnet (Data sambungan) | Conformance with EMC directive |
| Voltan bekalan pemancar (Keadaan ambien) | > 16 V (20 mA) |
| Keratan rentas konduktor pepejal maks. (Bekalan kuasa) | 1.5 mm² |
| Keratan rentas konduktor min. pepejal (Bekalan kuasa) | 0.2 mm² |
| Pekali suhu maksimum (Data sambungan) | < 0.01 %/K |
| Kuasa output maksimum Po (Komunikasi data (pintasan)) | 587 mW |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -40 °C ... 80 °C |
| Keratan rentas konduktor fleksibel maksimum (Bekalan kuasa) | 1.5 mm² |
| Keratan rentas konduktor min fleksibel (Bekalan kuasa) | 0.2 mm² |
| Penarafan mudah terbakar mengikut UL 94 (Data keselamatan) | V0 |
| Arus output maksimum Io (Komunikasi data (pintasan)) | 93 mA |
| Voltan keluaran maksimum Uo (Komunikasi data (pintasan)) | 25.2 V |
| Julat isyarat beban terkurang/beban terlampau (Keadaan ambien) | 0 mA ... 24 mA (Extended transmission range for diagnostics) |
| Tingkah laku output sekiranya berlaku ralat (Data input) | 0 mA (Cable break in the input) |
| Perlindungan polarisasi dan lonjakan (Keadaan ambien) | Yes |
| Kapasiti luaran maksimum Co (Komunikasi data (pintasan)) | 820 nF |
| Penarafan mudah terbakar mengikut UL 94 (Data sambungan) | V0 |
| Induktans dalaman maksimum Li (Komunikasi data (pintasan)) | negligible |
| Induktiviti luaran maksimum Lo (Komunikasi data (pintasan)) | 4 mH |
| Kapasitans dalaman maksimum Ci (Komunikasi data (pintasan)) | negligible |
| Voltan maksimum berkaitan keselamatan Um (Komunikasi data (pintasan)) | 253 V AC (125 V DC) |
Spesifikasi teknikal dan data prestasi