| Parameter | Nilai |
|---|---|
| (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | ICPLUS 915 NTC/PTC |
| Model (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | IC PLUS 915 J/K PT100 12V |
| Kuasa (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | according to the model |
| Format (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | Panel 74x32 |
| Prob (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | 1 PT100 or TCK/TCJ |
| Relay (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | 2 |
| Paparan (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | decimal point selectable * 3 digits and a half + sign |
| Kad Salinan (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | If |
| Rujukan (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | ICP22JI350000 |
| Dimensi (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | 74 x 32 x 59 mm |
| Port bersiri (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | TTL for connection to Copy Card, TelevisSystem / Modbus (requires Bus Adapter) |
| Input analog (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | 1 PTC or NTC * |
| Medan paparan (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | probe NTC: -50,0...110,0°Cprobe PTC: -55,0...140,0°C |
| Input digital (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | 1 digital input without voltage |
| Prob Kelembapan (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | If |
| Voltan bekalan (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | 12 Vac/vdc |
| Menyokong ModBus (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | If (need Bus Adapter) |
| Output digital (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | 1 SPDT 8(4)A 250Va1 SPST 8(4)A 250Va |
| Pengukuran medan (KAWALAN ELEKTRONIK, 2 TITIK TETAP (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | -from -50 to 140 ° C |
| Transduser Tekanan (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | If |
| Keserasian Televis (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) | If (need Bus Adapter) |
| * boleh dipilih mengikut parameter (KAWALAN ELEKTRONIK, 2 TITIK TETAPAN (SUHU, KELEMBAPAN, TEKANAN DAN KUANTITI LAIN)) |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi