| Parameter | Nilai |
|---|---|
| Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module | |
| Nota | Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector |
| Jenis | modular |
| Kedalaman | 109 mm |
| Lebar | 63 mm |
| Ketinggian | 224 mm |
| Cabutan semasa | max. 45 mA |
| Jenis produk | I/O component |
| Nota perhimpunan | To safeguard sufficient ventilation, ensure that there is an installation clearance of a minimum of 50 cm both above and below. |
| Kod ID (heks) | BF |
| Jenis pemasangan | DIN rail mounting |
| Kod ID (dis.) | 191 |
| Mod operasi | Process data mode with one byte |
| Keluarga produk | Inline |
| Voltan bekalan | 7.5 V DC (via voltage jumper) |
| Panjang daftar | 1 Byte |
| Kelas perlindungan | I (IEC 61140, EN 61140, VDE 0140-1) |
| Kaedah sambungan | Inline data jumper |
| Kod panjang (dec) | 129 |
| Kod panjang (heksadesimal) | 81 |
| Kedudukan pemasangan | Panel mounting on horizontal DIN rail |
| Penggunaan kuasa | max. 1.2 W (entire device) |
| Kawasan alamat input | 1 Byte |
| Kelajuan penghantaran | 500 kbps |
| Lukisan dimensi | |
| Kawasan alamat output | 1 Byte |
| Tahap perlindungan | IP20 |
| Mesej diagnostik | Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module |
| Bilangan antara muka | 2 |
| Saluran data proses | 8 bit |
| Julat voltan bekalan | 19.2 V DC ... 28.8 V DC (including all tolerances, including ripple) |
| Fizik penghantaran | Copper |
| Data parameter yang diperlukan | 5 Byte |
| Tekanan udara (operasi) | 70 kPa ... 106 kPa (up to 2000 m above sea level) |
| Data konfigurasi yang diperlukan | 5 Byte |
| Suhu ambien (operasi) | -25 °C ... 55 °C |
| Tekanan udara (penyimpanan/pengangkutan) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Kelembapan yang dibenarkan (operasi) | 10 % ... 85 % (non-condensing) |
| Voltan ujian: Bas tempatan/tahap 400 V | 1.2 kV AC, 50 Hz, 1 min. |
| Suhu ambien (penyimpanan/pengangkutan) | -25 °C ... 85 °C |
| Kelembapan yang dibenarkan (penyimpanan/pengangkutan) | 10 % ... 85 % (non-condensing) |
| Voltan ujian: Suis kawalan bas/brek tempatan | 1.2 kV AC, 50 Hz, 1 min. |
| Voltan ujian: Voltan bekalan tahap UL/400 V | 1.2 kV AC, 50 Hz, 1 min. |
| Voltan ujian: Voltan bekalan tahap AS/400 V | 1.2 kV AC, 50 Hz, 1 min. |
| Voltan ujian: Voltan bekalan UL/ suis kawalan brek | 1.2 kV AC, 50 Hz, 1 min. |
| Voltan ujian: Voltan bekalan AS/ suis kawalan brek | 1.2 kV AC, 50 Hz, 1 min. |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi