| Parameter | Nilai |
|---|---|
| Protection against polarity reversal (segment supply/main supply); Parallel diodes for protection against polarity reversal; in the event of an error the high current flowing through the diodes causes the fuse connected upstream to blow. | |
| Jenis | modular |
| Kedalaman | 71.5 mm |
| Lebar | 48.8 mm |
| Ketinggian | 135 mm |
| Cabutan semasa | max. 1.25 A (at nominal voltage; consisting of: 0.75 A DC for the communications power and 0.5 A DC for the analog voltage supply) |
| Jenis produk | I/O component |
| Kod ID (heks) | none |
| Jenis pemasangan | DIN rail mounting |
| Keluarga produk | Inline |
| Voltan bekalan | 24 V DC (via Inline connector) |
| Nama sambungan | Inline connector |
| Panjang daftar | 0 bit |
| Semakan artikel | 06 |
| Kelas perlindungan | III (IEC 61140, EN 61140, VDE 0140-1) |
| Panjang pelucutan | 8 mm |
| Kaedah sambungan | Inline shield connector |
| Skop penghantaran | including Inline connectors and marking fields |
| Kawasan alamat input | 0 Byte |
| Litar pelindung | Surge protection (segment supply, main supply, 24 V supply); Input protective diodes (can be destroyed by permanent overload)Pulse loads up to 1500 W are short circuited by the input protective diode. |
| Hartanah istimewa | for extending the Inline local bus |
| Kelajuan penghantaran | 500 kbps / 2 Mbps (Can be used in Inline stations with these transmission speeds) |
| Lukisan dimensi | |
| Nota mengenai permohonan | Only for industrial use |
| Kawasan alamat output | 0 Byte |
| Tahap perlindungan | IP20 |
| Bilangan antara muka | 1 (incoming local bus) |
| Julat voltan bekalan | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Fizik penghantaran | Copper |
| Data parameter yang diperlukan | 0 Byte |
| Tekanan udara (operasi) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Keratan rentas konduktor AWG | 28 ... 16 |
| Data konfigurasi yang diperlukan | 0 Byte |
| Keratan rentas konduktor tegar | 0.08 mm² ... 1.5 mm² |
| Nota tentang kaedah sambungan | Standard INTERBUS cable |
| Keratan rentas konduktor, tegar | 0.08 mm² ... 1.5 mm² |
| Suhu ambien (operasi) | -25 °C ... 55 °C |
| Tekanan udara (penyimpanan/pengangkutan) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Keratan rentas konduktor fleksibel | 0.08 mm² ... 1.5 mm² |
| Kelembapan yang dibenarkan (operasi) | 10 % ... 95 % (non-condensing) |
| Keratan rentas konduktor, fleksibel | 0.08 mm² ... 1.5 mm² |
| Suhu ambien (penyimpanan/pengangkutan) | -25 °C ... 85 °C |
| Bilangan peranti dengan saluran parameter | 63 |
| Kelembapan yang dibenarkan (penyimpanan/pengangkutan) | 10 % ... 95 % (non-condensing) |
| Pelesapan kuasa maksimum untuk keadaan nominal | 1.45 W |
| Bilangan peranti bas tempatan yang boleh disambungkan | max. 63 (without additional power terminal block, observe allowable total current consumption) |
| Voltan ujian: Bekalan bas tempatan masuk 5 V / Bekalan utama 24 V, Bekalan segmen 24 V | 500 V AC, 50 Hz, 1 min. |
| Voltan ujian: Bekalan utama 24 V, bekalan segmen 24 V, bekalan kuasa 24 V untuk menjana voltan UL dan UANA/pembumian berfungsi | 500 V AC, 50 Hz, 1 min. |
| Voltan ujian: Kuasa komunikasi 7.5 V, bekalan kuasa analog 24 V, bekalan kuasa 24 V untuk menjana voltan UL dan UANA/pembumian berfungsi | 500 V AC, 50 Hz, 1 min. |
| Voltan ujian: Bekalan bas tempatan masuk 5 V / kuasa komunikasi 7.5 V, bekalan kuasa analog 24 V, bekalan kuasa 24 V untuk menjana voltan ULand UANA | 500 V AC, 50 Hz, 1 min. |
| Voltan ujian: Kuasa komunikasi 7.5 V, bekalan kuasa analog 24 V, bekalan kuasa 24 V untuk menjana voltan ULand UANA/ bekalan utama 24 V, bekalan segmen 24 V | 500 V AC, 50 Hz, 1 min. |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi