| Parameter | Nilai |
|---|---|
| GTIN | 4017918893309 |
| Nota | Made to Order (non-returnable) |
| Kunci Pesanan | 1605001 |
| Halaman katalog | Page 553 (C-4-2015) |
| Unit pembungkusan | 1 pc |
| Negara asal | DE (Germany) |
| Nombor tarif tersuai | 85366990 |
| (Keadaan ambien) | 8 Nm (35 mm²) |
| Bahan sentuhan (Umum) | Copper alloy |
| Arus yang dinilai (Dimensi) | 100 A |
| Lebar (Data Komersial Utama) | 34.2 mm |
| (Piawaian dan Peraturan) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Ketinggian (Data Komersial Utama) | 50.3 mm |
| Panjang (Data Komersial Utama) | 29.4 mm |
| Profil sambungan (Dimensi) | 2 |
| Voltan lonjakan yang dinilai (Dimensi) | 8 kV |
| Bahan pembawa sentuh (Umum) | PC |
| Bahan permukaan sentuh (Umum) | Ag |
| Voltan yang dinilai (III/3) (Dimensi) | 1000 V |
| Siri (Ciri-ciri mekanikal) | HC-M-HS |
| Berat setiap Keping (tidak termasuk pembungkusan) | 71.100 g |
| Soket heksagon (Keadaan ambien) | SW 4 |
| RoHS (Piawaian dan Peraturan) China | Environmentally Friendly Use Period = 50 |
| Tork pengetatan (Keadaan ambien) | 6 Nm (16 mm²) |
| Sambungan (Ciri-ciri mekanikal) | Note for axial connection methodThe specified conductor cross sections refer to the geometric cross section of the used conductor.The use of conductors with a geometric cross section that deviates greatly from the nominal cross section of the conductor should be checked first.The wiring space of the axial screw technology has been designed for fine strand conductors as per VDE 0295 class 5. Deviating conductor superstructures (e.g. class 6 conductors) must be checked before use.ConnectionIt must be ensured before installation that the ball screw is completely turned back (chamber is open). Twisting the conductors is not allowed. The cores must be pushed up to the end of the contact chamber (until the contact is insulated). Keep the core in this position and tighten it using an Allen key. The required core end must be cut before a reconnection. Tightening the connection screw is allowed only once in order to prevent a breakage of the litz wire. |
| Ketinggian minimum perumahan (Keadaan ambien) | 72 mm |
| Keratan rentas konduktor (Keadaan ambien) | 16 mm² ... 35 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Kaedah sambungan (Ciri-ciri mekanikal) | Axial screw connection |
| Sambungan dalam akaun dengan standard (Data bahan) | CUL |
| Tahap pencemaran (Ciri-ciri mekanikal) | 3 |
| Kitaran pemasukan/penarikan (Keadaan ambien) | ≥ 500 |
| Keratan rentas sambungan AWG (Keadaan ambien) | 4 ... 2 |
| Kategori voltan lampau (Ciri-ciri mekanikal) | III |
| Arahan pemasangan (Ciri-ciri mekanikal) | Use HC housing h >= 72 mm. Connection of the wires using a 4 mm. Allen wrench.Axial screw connection only for stranded wires.Plug-in connections may only be operated only when there is no load/voltage. |
| Bilangan slot modul (Ciri-ciri mekanikal) | 2 |
| Penarafan mudah terbakar mengikut UL 94 (Data bahan) | V0 |
| Diameter dawai termasuk penebat (Keadaan ambien) | 11.4 mm |
| Suhu ambien (operasi) (Ciri-ciri elektrik) | -40 °C ... 125 °C |
| Panjang pelucutan wayar individu (Keadaan ambien) | 13 mm |
| Penarafan mudah terbakar mengikut UL 94 (Ciri-ciri mekanikal) | V0 |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi