HC-M-02-HS-70/22-MOD-BU - HC-M-02-HS-70/22-MOD-BU 1585731 PHOENIX CONTACT Contact insert module
Dalam Stok Produk Hangat

HC-M-02-HS-70/22-MOD-BU

HC-M-02-HS-70/22-MOD-BU 1585731 PHOENIX CONTACT Contact insert module

$0.00USD
4544 dalam stok
Spesifikasi Utama
GTIN:4046356308236
Nota:Made to Order (non-returnable)
Kunci Pesanan:1585731
Halaman katalog:Page 553 (C-4-2015)
Maklumat Pembekal
Produk: 0
Biasanya dihantar dalam 2-3 hari bekerja
Kualiti Dijamin
Penghantaran Pantas
Sokongan Teknikal

Spesifikasi Teknikal

ParameterNilai
GTIN4046356308236
NotaMade to Order (non-returnable)
Kunci Pesanan1585731
Halaman katalogPage 553 (C-4-2015)
Unit pembungkusan2 pc
Negara asalDE (Germany)
Nombor tarif tersuai85366990
(Keadaan ambien)5 Nm (22 mm²)
Kuantiti pesanan minimum100 pc
Bahan sentuhan (Umum)Copper alloy
Arus yang dinilai (Dimensi)70 A
Lebar (Data Komersial Utama)34.2 mm
Ketinggian (Data Komersial Utama)46.5 mm
Panjang (Data Komersial Utama)14.6 mm
Profil sambungan (Dimensi)2
Voltan lonjakan yang dinilai (Dimensi)8 kV
Bahan pembawa sentuh (Umum)PC
Bahan permukaan sentuh (Umum)Ag
Voltan yang dinilai (III/3) (Dimensi)1000 V
Siri (Ciri-ciri mekanikal)HC-M-02
Berat setiap Keping (tidak termasuk pembungkusan)30.900 g
Soket heksagon (Keadaan ambien)SW2,5
Tork pengetatan (Keadaan ambien)4 Nm (for 14 mm² ... 16 mm²)
Sambungan (Ciri-ciri mekanikal)Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Ketinggian minimum perumahan (Keadaan ambien)72 mm
Keratan rentas konduktor (Keadaan ambien)14 mm² ... 22 mm²
Kaedah sambungan (Ciri-ciri mekanikal)Axial screw connection
Sambungan dalam akaun dengan standard (Data bahan)UL
Tahap pencemaran (Ciri-ciri mekanikal)3
Kitaran pemasukan/penarikan (Keadaan ambien)≥ 500
Keratan rentas sambungan AWG (Keadaan ambien)6 ... 4
Kategori voltan lampau (Ciri-ciri mekanikal)III
Arahan pemasangan (Ciri-ciri mekanikal)Use 2.5 mm Allen wrenches for axial connection. Only for stranded wires. For housing heights h ≥ 52 mm. Plug-in connections may only be operated only when there is no load/voltage.
Bilangan slot modul (Ciri-ciri mekanikal)1
Penarafan mudah terbakar mengikut UL 94 (Data bahan)V0
Diameter dawai termasuk penebat (Keadaan ambien)10 mm
Suhu ambien (operasi) (Ciri-ciri elektrik)-40 °C ... 125 °C
Panjang pelucutan wayar individu (Keadaan ambien)11 mm +1 (14 mm² ... 16 mm²)
Penarafan mudah terbakar mengikut UL 94 (Ciri-ciri mekanikal)V0

Penerangan Produk

More details
Ciri-ciri Utama
  • Kualiti gred industri
  • Patuh RoHS
  • Sijil CE
  • Jaminan 1 tahun

Dokumen Produk

Lembaran Data

Spesifikasi teknikal dan data prestasi