| Parameter | Nilai |
|---|---|
| GTIN | 4046356308212 |
| Nota | Made to Order (non-returnable) |
| Kunci Pesanan | 1585715 |
| Halaman katalog | Page 553 (C-4-2015) |
| Unit pembungkusan | 2 pc |
| Negara asal | DE (Germany) |
| Nombor tarif tersuai | 85366990 |
| (Keadaan ambien) | 4 Nm (16 mm²) |
| Kuantiti pesanan minimum | 2 pc |
| Bahan sentuhan (Umum) | Copper alloy |
| Arus yang dinilai (Dimensi) | 70 A |
| Lebar (Data Komersial Utama) | 34.2 mm |
| (Piawaian dan Peraturan) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Ketinggian (Data Komersial Utama) | 46.5 mm |
| Panjang (Data Komersial Utama) | 14.6 mm |
| Profil sambungan (Dimensi) | 2 |
| Voltan lonjakan yang dinilai (Dimensi) | 8 kV |
| Bahan pembawa sentuh (Umum) | PC |
| Bahan permukaan sentuh (Umum) | Ag |
| Voltan yang dinilai (III/3) (Dimensi) | 1000 V |
| Siri (Ciri-ciri mekanikal) | HC-M-HS |
| Berat setiap Keping (tidak termasuk pembungkusan) | 31.200 g |
| Soket heksagon (Keadaan ambien) | SW2,5 |
| RoHS (Piawaian dan Peraturan) China | Environmentally Friendly Use Period = 50 |
| Tork pengetatan (Keadaan ambien) | 2 Nm (6 mm²) |
| Sambungan (Ciri-ciri mekanikal) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. |
| Ketinggian minimum perumahan (Keadaan ambien) | 72 mm |
| Keratan rentas konduktor (Keadaan ambien) | 6 mm² ... 16 mm² |
| Kaedah sambungan (Ciri-ciri mekanikal) | Axial screw connection |
| Sambungan dalam akaun dengan standard (Data bahan) | UL |
| Tahap pencemaran (Ciri-ciri mekanikal) | 3 |
| Kitaran pemasukan/penarikan (Keadaan ambien) | ≥ 500 |
| Keratan rentas sambungan AWG (Keadaan ambien) | 8 ... 6 |
| Kategori voltan lampau (Ciri-ciri mekanikal) | III |
| Arahan pemasangan (Ciri-ciri mekanikal) | Use 2.5 mm Allen wrenches for axial connection. Only for stranded wires. For housing heights h ≥ 52 mm. Plug-in connections may only be operated only when there is no load/voltage. |
| Bilangan slot modul (Ciri-ciri mekanikal) | 1 |
| Penarafan mudah terbakar mengikut UL 94 (Data bahan) | V0 |
| Diameter dawai termasuk penebat (Keadaan ambien) | 8.9 mm |
| Suhu ambien (operasi) (Ciri-ciri elektrik) | -40 °C ... 125 °C |
| Panjang pelucutan wayar individu (Keadaan ambien) | 11 mm +1 |
| Penarafan mudah terbakar mengikut UL 94 (Ciri-ciri mekanikal) | V0 |