HC-HS 2-D7-EBUS - HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert
Dalam Stok Produk Hangat

HC-HS 2-D7-EBUS

HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert

$35.46USD
326 dalam stok
Spesifikasi Utama
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Jenis:D7
Ujian:DIN VDE 0627/86
Lebar:21 mm
Maklumat Pembekal
Produk: 0
Biasanya dihantar dalam 2-3 hari bekerja
Kualiti Dijamin
Penghantaran Pantas
Sokongan Teknikal

Spesifikasi Teknikal

ParameterNilai
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
JenisD7
UjianDIN VDE 0627/86
Lebar21 mm
Ketinggian34.8 mm
Panjang21 mm
SiriHC-HS
Jeneralfor HC-D7 housing, axial connection 2.0 mm, Allen key
PermohonanPower
Jenis produkContact insert with a fixed no. of positions
Nota perhimpunanTo ensure correct use, installation in housing with IP54 protection or better is required
Arus yang dinilai40 A
Semakan artikel04
Diameter sentuhan4 mm
Bahan sentuhCopper alloy
Soket heksagonSW2,0
Penomboran kenalan1 - 2
Tork pengetatan0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Profil sambungan2+PE
Tahap pencemaran3
Lukisan dimensi
Bilangan jawatan2
Voltan lonjakan yang dinilai6 kV
Kategori voltan lampauIII
Teknologi sambunganAxial screw connection
Jenis bahan sentuhturned
Bilangan kenalan kuasa2
Voltan yang dinilai (III/3)400 V
Keratan rentas konduktor4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used)
Bahan pembawa sentuhPC
Bahan permukaan sentuhAg
Kitaran pemasukan/penarikan balik≥ 500
Keratan rentas sambungan AWG10 ... 8
Suhu ambien (operasi)-40 °C ... 125 °C (including heating up of contacts)
Sambungan dalam akaun dengan standardIEC / EN
Peraturan pembinaan dan pengujianDIN VDE 0627/86
Penarafan mudah terbakar mengikut UL 94V0
Panjang pelucutan wayar individu8 mm +1 mm

Penerangan Produk

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Female, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power