| Parameter | Nilai |
|---|---|
| 18 V DC ... 32 V DC | |
| Fius | electronic |
| Nota | No. 14 |
| Jenis | DIN rail module, one-piece |
| Warna | black (RAL 9005) |
| Kedalaman | 80 mm |
| Lebar | 12.5 mm |
| Ketinggian | 83 mm |
| Jeneral | When mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor).Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC).Parallel connection of multiple circuit breakers is not permitted. |
| Voltan | < 3 V DC (Low state) |
| Jenis fius | Automatic device |
| Matikan | typ. 1.8 x IN |
| Jenis produk | Device circuit breakers |
| Panjang denyutan nadi | min. 10 ms |
| Benang skru | M4 |
| Penurunan voltan | 130 mV (at IN) |
| Ujian kelembapan | 96 h, 95 % RH, 40 °C |
| Voltan input | max. 32 V DC |
| Jenis pemasangan | DIN rail: 35 mm |
| Arus keluaran | max. 0.2 A (Short-circuit-proof) |
| Voltan keluaran | 24 V DC |
| Keluarga produk | EC-E |
| Nama sambungan | Auxiliary contact |
| Tinggi NS 35/15 | 90.5 mm |
| Bilangan saluran | 1 |
| Kelewatan menghidupkan | typ. 0.5 s |
| Kaedah tersandung | E (electronic) |
| Semakan artikel | 02 |
| Tinggi NS 35/7,5 | 83 mm |
| Panjang pelucutan | 10 mm |
| Kaedah sambungan | Screw connection |
| Keratan rentas AWG | 26 ... 6 (converted acc. to IEC) |
| Voltan operasi | 24 V DC |
| Tork pengetatan | ... 1.2 Nm |
| Arus nominal IN | 6 A |
| Fungsi pensuisan | Reset input |
| Penggunaan semasa | typ. 2.6 mA (at 24 V DC) |
| Tahap pencemaran | 2 |
| Kekuatan dielektrik | max. 32 V DC (Load circuit) |
| Bilangan jawatan | 1 |
| Voltan lonjakan yang dinilai | 0.5 kV |
| Tahap perlindungan | IP20 (Housing) |
| Beban kapasitif maksimum | 20000 µF |
| Fius sandaran yang diperlukan | not required, integrated failsafe element |
| Keratan rentas nominal | 16.00 mm² |
| Kapasiti pensuisan ICN | Active current limitation |
| Piawaian/spesifikasi | UL 508 |
| Had arus aktif | active |
| MTBF (IEC 61709, SN 29500) | 7430000 h (at 25 °C with 80 % load) |
| Keratan rentas konduktor AWG | 20 ... 6 |
| Keratan rentas konduktor tegar | 0.5 mm² ... 16 mm² |
| Suhu ambien (operasi) | 0 °C ... 50 °C (non-condensing) |
| Julat arus litar tertutup I0 | typ. 25 mA ±5 mA (When switched on) |
| Keratan rentas konduktor fleksibel | 0.5 mm² ... 16 mm² |
| Penarafan mudah terbakar mengikut UL 94 | V0 |
| Suhu ambien (penyimpanan/pengangkutan) | -20 °C ... 70 °C |
| Keratan rentas konduktor, fleksibel [AWG] | 20 ... 6 (converted acc. to IEC) |
| 2 konduktor dengan keratan rentas yang sama, pepejal | 0.5 mm² ... 4 mm² |
| 2 konduktor dengan keratan rentas yang sama, fleksibel | 0.5 mm² ... 4 mm² |
| 2 konduktor dengan keratan rentas AWG yang sama tegar | 20 ... 12 (converted acc. to IEC) |
| 2 konduktor dengan keratan rentas AWG fleksibel yang sama | 20 ... 12 (converted acc. to IEC) |
| Keratan rentas konduktor fleksibel (ferrule dengan sarung plastik) | 0.5 mm² ... 10 mm² |
| Keratan rentas konduktor fleksibel (ferrule tanpa sarung plastik) | 0.5 mm² ... 10 mm² |
| Keratan rentas konduktor, fleksibel, dengan ferrule, dengan sarung plastik | 0.5 mm² ... 10 mm² |
| Keratan rentas konduktor fleksibel, dengan ferrule tanpa sarung plastik | 0.5 mm² ... 10 mm² |
| 2 konduktor dengan keratan rentas yang sama, fleksibel, dengan ferrule tanpa sarung plastik | 0.5 mm² ... 2.5 mm² |
| 2 konduktor dengan keratan rentas yang sama, fleksibel, dengan ferrule TWIN dengan sarung plastik | 0.5 mm² ... 6 mm² |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi